The PAD uses the retry timer on autoconnect calls to attempt to establish the data call if a previous try is unsuccessful or if an established data call is cleared. On a dial port, the retry timer value must be less than the value of the dial port CALL timeout option that applies to all dial ports.
This parameter is used only when an Autoconnect selection command has been specified.
Parsed from file pacesetter70-soho.mib.txt
Company: adc_kentrox
Module: PACESETTER-COMMON-MIB
Vendor: ADC Kentrox
Module: PACESETTER-COMMON-MIB (pacesetter-cellworx.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
(
0..255 )
Automatically extracted from www.mibdepot.com
padOperRetryTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-only STATUS mandatory DESCRIPTION "The PAD uses the retry timer on autoconnect calls to attempt to establish the data call if a previous try is unsuccessful or if an established data call is cleared. On a dial port, the retry timer value must be less than the value of the dial port CALL timeout option that applies to all dial ports. This parameter is used only when an Autoconnect selection command has been specified." ::= { padOperEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.358.4.4.7.1.1.1.1 | padOperPortIndex | 0 | 0 | A unique value for each port. The interface associated with a particular value of this object is the same interface as identif… |
1.3.6.1.4.1.358.4.4.7.1.1.1.2 | padOperDSSFlowControl | 0 | 0 | DSS flow control specifies that RTS/CTS data set signals are used for flow control. If DSS flow control is selected, the PAD f… |
1.3.6.1.4.1.358.4.4.7.1.1.1.3 | padOperX28Profile | 0 | 0 | The X.28 profile index specifies the number of one of the pre-defined sets of X.3 parameter values that control the line betwee… |
1.3.6.1.4.1.358.4.4.7.1.1.1.4 | padOperX29Profile | 0 | 0 | The X.29 profile index specifies one of the pre-defined sets of X.3 parameter values that govern the interaction between the ca… |
1.3.6.1.4.1.358.4.4.7.1.1.1.5 | padOperAutoconnectSelectionCommand | 0 | 0 | The pre-stored X.28 selection command is used to indicate whether the PAD automatically attempts to establish a data call usin… |
1.3.6.1.4.1.358.4.4.7.1.1.1.9 | padOperX121Address | 0 | 0 | An X.121 address is required only if the port is configured to receive outgoing data calls. The address is used for routing c… |
1.3.6.1.4.1.358.4.4.7.1.1.1.11 | padOperInactivityTimer | 0 | 0 | The inactivity timer clears a users' call is there is no activity (transmission or reception of data) for the specified number … |
1.3.6.1.4.1.358.4.4.7.1.1.1.12 | padOperCallAddress | 0 | 0 | The Call Address parameter indicates whether the PAD inserts a calling address in a Call Request packet and a called address in… |