absStateOfCharge OBJECT-TYPE
SYNTAX INTEGER(0..100)
ACCESS read-only
STATUS optional
DESCRIPTION "Predicted remaining capacity expressed as % of DesignCapacity() (0-100). Value of -1 means not supported"
View at oid-info.com
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.1 | bbuID | 0 | 0 | bbuID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "BBUID for this BBU.(Unique)" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.2 | batteryType | 0 | 0 | batteryType OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "BBU Type." |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.3 | nextLearnTime | 0 | 0 | nextLearnTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Time of next scheduled learn cycle (seco… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.5 | fullChargeCapacity | 0 | 0 | fullChargeCapacity OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Predicted pack capacity when it is … |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.6 | averageEmptyTime | 0 | 0 | averageEmptyTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "One-minute rolling average of the pre… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.7 | cycleCount | 0 | 0 | cycleCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Number of charge cycles the battery has exp… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.8 | firmwareStatus | 0 | 0 | firmwareStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Condition of battery in following… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.9 | voltage | 0 | 0 | voltage OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Accurate battery terminal voltage in mV, resol… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.10 | autoLearnPeriod | 0 | 0 | autoLearnPeriod OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Time (in seconds) between learn cycles… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.11 | relStateOfCharge | 0 | 0 | relStateOfCharge OBJECT-TYPE SYNTAX INTEGER(0..100) ACCESS read-only STATUS optional DESCRIPTION "Predicted remaining capacity … |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.12 | capacityRemain | 0 | 0 | capacityRemain OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Predicted charge or energy remaining in… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.13 | runTimeToEmpty | 0 | 0 | runTimeToEmpty OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Relative gain or loss in remaining life… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.14 | avgTimeToFull | 0 | 0 | avgTimeToFull OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "One-minute rolling average of predicted … |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.15 | errorMargin | 0 | 0 | errorMargin OBJECT-TYPE SYNTAX INTEGER(2..100) ACCESS read-only STATUS optional DESCRIPTION "Expected margin of error (%) in ch… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16 | temperature | 0 | 0 | temperature OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Battery temperature in degree Centig… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.17 | mfgName | 0 | 0 | mfgName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Battery manufacturer\s name" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.18 | deviceName | 0 | 0 | deviceName OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Battery name" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.19 | serialNumber | 0 | 0 | serialNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Battery serialNumber" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20 | chargerStatus | 0 | 0 | chargerStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Battery charger status. Values: N/A(-1),… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.21 | adpID | 0 | 0 | adpID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "The adapter id where BBU is attached" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.22 | remainingCapAlarm | 0 | 0 | remainingCapAlarm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Remaining capacity to alarm. Value o… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.23 | remainingTimeAlarm | 0 | 0 | remainingTimeAlarm OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Remaining time to alarm. Value of -… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.24 | bbu-current | 0 | 0 | bbu-current OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Current(In mA) being supplied (or accepted… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.25 | gasGaugeStatus | 0 | 0 | gasGaugeStatus OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "Gas gauge status" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.26 | bbuFRU | 0 | 0 | bbuFRU OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "bbu FRU" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27 | batteryReplacement | 0 | 0 | batteryReplacement OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS optional DESCRIPTION "This property denotes whether the B… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.28 | bbuRetentiontime | 0 | 0 | bbuRetentiontime OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "The total no. of hours the batt… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.29 | bbuState | 0 | 0 | bbuState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "This property gives the Information abo… |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.30 | memoryModuleFRU | 0 | 0 | memoryModuleFRU OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "tmm FRU" |
1.3.6.1.4.1.3582.4.1.4.1.6.2.1.31 | bbuFirmwareVersion | 0 | 0 | bbuFirmwareVersion OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS optional DESCRIPTION "Battery Firmware Version" |