If 'true(1)', this Link will automatically disable all M ports
when the CF state becomes isolated(1). The M ports will be
automatically re-enabled (if not previously disabled by
management) when the CF state transitions out of the
isolated(1) state. If 'false(2)' (the default), this link will
not automatically disable all M ports based on CF state.
This feature is used for increased reliability in
configurations having multiple levels of dual-homed
concentrators. For example, if a concentrator on the
dual ring becomes isolated (e.g., a backhoe cuts the
cables), all lower-level concentrators that are dual-homed
to this concentrator are isolated. With this feauture,
the concentrator on the dual-ring will disable all of
its M ports forcing the lower-level dual-homed concentrators
to switch to their standby links. This prevents the
lower-lever concentrators and stations from remaining
isolated.
Parsed from file dec_elan20.txt
Company: dec
Module: DEC-ELAN-MIB
Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.
esysFddiAutoDisconnect OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "If 'true(1)', this Link will automatically disable all M ports when the CF state becomes isolated(1). The M ports will be automatically re-enabled (if not previously disabled by management) when the CF state transitions out of the isolated(1) state. If 'false(2)' (the default), this link will not automatically disable all M ports based on CF state. This feature is used for increased reliability in configurations having multiple levels of dual-homed concentrators. For example, if a concentrator on the dual ring becomes isolated (e.g., a backhoe cuts the cables), all lower-level concentrators that are dual-homed to this concentrator are isolated. With this feauture, the concentrator on the dual-ring will disable all of its M ports forcing the lower-level dual-homed concentrators to switch to their standby links. This prevents the lower-lever concentrators and stations from remaining isolated." ::= { esysConcConfig 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.1.2.4.3.0 | esysFddiAutoDisconnect | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.1.2.4.1 | esysFRUConfigTable | 1 | 7 | A list of configuration table entries. |
1.3.6.1.4.1.36.2.18.1.2.4.2 | esysFddiPortTrapSwitch | 1 | 1 | This is a switch to enable or diable FDDI port up and port down traps. When set to true, the concentrator will send a trap when … |