This object allows the management action of initializing a device and
forcing it to run selftest. It can also be used to reset all
information added to the device's NVRAM. When read, it returns a value
of other(1). When set to a value of reset(2) the bridge will empty the
forwarding database and start relearning. When set to resetToFactory(3)
the bridge will empty the forwarding database, reset spanning tree and
clear all protocol filters and password.
Parsed from file DEChub90.mib.txt
Company: None
Module: DECHUB90-MIB
This object allows the management action of initializing a device and
forcing it to run selftest. It can also be used to reset all
information added to the device's NVRAM. When read, it returns a value
of other(1). When set to a value of reset(2) the bridge will empty the
forwarding database and start relearning. When set to resetToFactory(3)
the bridge will empty the forwarding database, reset spanning tree and
clear all protocol filters and password.
Parsed from file DECHUB90-MIB.mib
Module: DECHUB90-MIB
Vendor: DEC
Module: DECHUB90-MIB
[Automatically extracted from oidview.com]
dbSysInitSwitch OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2), resetToFactory(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management action of initializing a device and forcing it to run selftest. It can also be used to reset all information added to the device's NVRAM. When read, it returns a value of other(1). When set to a value of reset(2) the bridge will empty the forwarding database and start relearning. When set to resetToFactory(3) the bridge will empty the forwarding database, reset spanning tree and clear all protocol filters and password." ::= { dbSysChar 2 }
dbSysInitSwitch OBJECT-TYPE SYNTAX INTEGER { other(1), reset(2), resetToFactory(3) } ACCESS read-write STATUS mandatory DESCRIPTION "This object allows the management action of initializing a device and forcing it to run selftest. It can also be used to reset all information added to the device's NVRAM. When read, it returns a value of other(1). When set to a value of reset(2) the bridge will empty the forwarding database and start relearning. When set to resetToFactory(3) the bridge will empty the forwarding database, reset spanning tree and clear all protocol filters and password." ::= { dbSysChar 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.10.5.1.1.2.0 | dbSysInitSwitch | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.10.5.1.1.1 | dbSysRomVersion | 1 | 1 | The version number of the software stored in ROM. The return value is encoded as (major_version*10 + minor version). For examp… |