The value of sysUpTime at the start of the interval over which this
sample was measured. If the probe keeps track of the time of day,
it should start the first sample of the history at a time such that
when the next hour of the day begins, a sample is started at that
instant. Note that following this rule may require the probe to
delay collecting the first sample of the history, as each sample
must be of the same interval. Also note that the sample which is
currently being collected is not accessible in this table until the
end of its interval.
Parsed from file hubmg3-0.mib.txt
Company: None
Module: DECHUB900-HUBMGR-MIB-V3-0
The value of sysUpTime at the start of the interval over which this
sample was measured. If the probe keeps track of the time of day,
it should start the first sample of the history at a time such that
when the next hour of the day begins, a sample is started at that
instant. Note that following this rule may require the probe to
delay collecting the first sample of the history, as each sample
must be of the same interval. Also note that the sample which is
currently being collected is not accessible in this table until the
end of its interval.
Parsed from file DECHUB900-HUBMGR-MIB-V3-0.mib
Module: DECHUB900-HUBMGR-MIB-V3-0
Vendor: DEC
Module: DECHUB900-HUBMGR-MIB-V3-0
[Automatically extracted from oidview.com]
hubEtherHistoryIntervalStart OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval." ::= { hubEtherHistoryEntry 3 }
hubEtherHistoryIntervalStart OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime at the start of the interval over which this sample was measured. If the probe keeps track of the time of day, it should start the first sample of the history at a time such that when the next hour of the day begins, a sample is started at that instant. Note that following this rule may require the probe to delay collecting the first sample of the history, as each sample must be of the same interval. Also note that the sample which is currently being collected is not accessible in this table until the end of its interval." ::= { hubEtherHistoryEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.1 | hubEtherHistoryIndex | 0 | 0 | None |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.2 | hubEtherHistorySampleIndex | 0 | 0 | An index that uniquely identifies the particular sample this entry represents among all samples associated with the same hubHisto… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.4 | hubEtherHistoryDropEvents | 0 | 0 | The total number of events in which packets were dropped by the probe due to lack of resources during this sampling interval. Not… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.5 | hubEtherHistoryOctets | 0 | 0 | The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but includin… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.6 | hubEtherHistoryPkts | 0 | 0 | The number of packets (including bad packets) received during this sampling interval. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.7 | hubEtherHistoryBroadcastPkts | 0 | 0 | The number of good packets received during this sampling interval that were directed to the broadcast address. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.8 | hubEtherHistoryMulticastPkts | 0 | 0 | The number of good packets received during this sampling interval that were directed to a multicast address. Note that this num… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.9 | hubEtherHistoryCRCAlignErrors | 0 | 0 | The number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets)… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.10 | hubEtherHistoryUndersizePkts | 0 | 0 | The number of packets received during this sampling interval that were less than 64 octets long (excluding framing bits but incl… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.11 | hubEtherHistoryOversizePkts | 0 | 0 | The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but inclu… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.12 | hubEtherHistoryFragments | 0 | 0 | The total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bi… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.13 | hubEtherHistoryJabbers | 0 | 0 | The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but inclu… |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.14 | hubEtherHistoryCollisions | 0 | 0 | The best estimate of the total number of collisions on this Ethernet segment during this sampling interval. |
1.3.6.1.4.1.36.2.18.11.1.2.1.2.5.4.1.15 | hubEtherHistoryUtilization | 0 | 0 | The best estimate of the mean physical layer network utilization on this interface during this sampling interval, in hundredths … |