When read, this object returns the current status of
this port.
This object may also be used to shut down a port
that is currently connected(2), disconnected(3), or
isolated(5), by setting this object to the value
shut-down(4). A port that has been shut down due to
security violations, or by management, may be brought
back up by setting this object to connected(2). Any
other values for this object are rejected for a set
operation.
All traffic (including in-band management traffic
addressed to the switch, if any) on a port that has
been shut down is filtered, no counters are
incremented, and no frames are transmitted or
forwarded on such a port.
Parsed from file DEChub900-Switch.mib.txt
Company: None
Module: ESWITCH-MIB-V3-0
When read, this object returns the current status of
this port.
This object may also be used to shut down a port
that is currently connected(2), disconnected(3), or
isolated(5), by setting this object to the value
shut-down(4). A port that has been shut down due to
security violations, or by management, may be brought
back up by setting this object to connected(2). Any
other values for this object are rejected for a set
operation.
All traffic (including in-band management traffic
addressed to the switch, if any) on a port that has
been shut down is filtered, no counters are
incremented, and no frames are transmitted or
forwarded on such a port.
Parsed from file ESWITCH-MIB-V3-0.mib
Module: ESWITCH-MIB-V3-0
Vendor: DEC
Module: ESWITCH-MIB-V3-0
[Automatically extracted from oidview.com]
eSwitchPortStatus OBJECT-TYPE SYNTAX INTEGER { undefined(1), connected(2), disconnected(3), shutdown(4), isolated(5) } ACCESS read-write STATUS mandatory DESCRIPTION "When read, this object returns the current status of this port. This object may also be used to shut down a port that is currently connected(2), disconnected(3), or isolated(5), by setting this object to the value shut-down(4). A port that has been shut down due to security violations, or by management, may be brought back up by setting this object to connected(2). Any other values for this object are rejected for a set operation. All traffic (including in-band management traffic addressed to the switch, if any) on a port that has been shut down is filtered, no counters are incremented, and no frames are transmitted or forwarded on such a port." ::= { eSwitchPortEntry 3 }
eSwitchPortStatus OBJECT-TYPE SYNTAX INTEGER { undefined(1), connected(2), disconnected(3), shutdown(4), isolated(5) } ACCESS read-write STATUS mandatory DESCRIPTION "When read, this object returns the current status of this port. This object may also be used to shut down a port that is currently connected(2), disconnected(3), or isolated(5), by setting this object to the value shut-down(4). A port that has been shut down due to security violations, or by management, may be brought back up by setting this object to connected(2). Any other values for this object are rejected for a set operation. All traffic (including in-band management traffic addressed to the switch, if any) on a port that has been shut down is filtered, no counters are incremented, and no frames are transmitted or forwarded on such a port." ::= { eSwitchPortEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.11.7.2.1.1.1 | eSwitchPortIndex | 0 | 0 | The port number of the switch port for which this entry defines various characteristics. |
1.3.6.1.4.1.36.2.18.11.7.2.1.1.2 | eSwitchPortFailed | 0 | 0 | This object assumes the value failed(2), if the corresponding port is present, but has been determined to be faulty and has been … |
1.3.6.1.4.1.36.2.18.11.7.2.1.1.4 | eSwitchPortShutDownReason | 0 | 0 | The reason why this port is currently shut down. A value of none(1) is returned, if the port is not currently shutdown. A value o… |
1.3.6.1.4.1.36.2.18.11.7.2.1.1.5 | eSwitchPortSwitchingMode | 0 | 0 | This object defines the switching mode in which this port operates. The switching mode of a port determines whether or not it lea… |