One threshold alarm set on some particular integer-valued variable.
An alarm entry is created by the management console. It uses the
current value of svrAlarmNextThrIndex to name the instances of
the row variables, and sets its svrThrStatus to underCreation.
When creating a theshold entry for the first time, issue a set
request on svrThrStatus.
The remaining row variables may be set in the same operation, or in
subsequent operations. Those not set will have retain their default
values as described. The following variable values MUST be set
before enabling the alarm:
svrThrStatus must be set to underCreation
svrThrVariableName
svrThrThresholdValue
Parsed from file dec-svrMgt.mib.txt
Company: None
Module: SVRMGT-MIB
One threshold alarm set on some particular integer-valued variable.
An alarm entry is created by the management console. It uses the
current value of svrAlarmNextThrIndex to name the instances of
the row variables, and sets its svrThrStatus to underCreation.
When creating a theshold entry for the first time, issue a set
request on svrThrStatus.
The remaining row variables may be set in the same operation, or in
subsequent operations. Those not set will have retain their default
values as described. The following variable values MUST be set
before enabling the alarm:
svrThrStatus must be set to underCreation
svrThrVariableName
svrThrThresholdValue
Parsed from file SVRMGT-MIB.mib
Module: SVRMGT-MIB
Vendor: DEC
Module: SVRMGT-MIB
[Automatically extracted from oidview.com]
svrThresholdEntry OBJECT-TYPE SYNTAX SvrThresholdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "One threshold alarm set on some particular integer-valued variable. An alarm entry is created by the management console. It uses the current value of svrAlarmNextThrIndex to name the instances of the row variables, and sets its svrThrStatus to underCreation. When creating a theshold entry for the first time, issue a set request on svrThrStatus. The remaining row variables may be set in the same operation, or in subsequent operations. Those not set will have retain their default values as described. The following variable values MUST be set before enabling the alarm: svrThrStatus must be set to underCreation svrThrVariableName svrThrThresholdValue " INDEX { svrThrIndex } ::= { svrThresholdTable 1 }
svrThresholdEntry OBJECT-TYPE SYNTAX SvrThresholdEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "One threshold alarm set on some particular integer-valued variable. An alarm entry is created by the management console. It uses the current value of svrAlarmNextThrIndex to name the instances of the row variables, and sets its svrThrStatus to underCreation. When creating a theshold entry for the first time, issue a set request on svrThrStatus. The remaining row variables may be set in the same operation, or in subsequent operations. Those not set will have retain their default values as described. The following variable values MUST be set before enabling the alarm: svrThrStatus must be set to underCreation svrThrVariableName svrThrThresholdValue " INDEX { svrThrIndex } ::= { svrThresholdTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.36.2.18.22.2.2.3.1.1 | svrThrIndex | 0 | 0 | A locally-unique index value. On creation, this should be set to the value of svrAlarmNextThrIndex. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.2 | svrThrStatus | 0 | 0 | This variable describes the status of the row. When the row is created with the initial set, svrThrStatus must be set to underCr… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.3 | svrThrVariableName | 0 | 0 | The OID of an integer-valued variable to be tested against this threshold. On row creation, this variable will equal the value … |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.4 | svrThrValueType | 0 | 0 | Is this an absolute value or a delta value. The deltaValue is calculated by taking the current value and subtracting svtThrLastV… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.5 | svrThrAlarmType | 0 | 0 | Is this a greater than, greater than or equal to, equal to, less than or equal to, or less than alarm? Greater Than or Greater T… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.6 | svrThrSampleInterval | 0 | 0 | Interval in seconds between polls to check for threshold exceptions. Minimum Value is 1. The default value on row creation is 30… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.7 | svrThrPersistent | 0 | 0 | True if this threshold should persist across agent restarts. Default value on row creation is FALSE. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.8 | svrThrThresholdValue | 0 | 0 | This is the thresholding value which gets compared to the current or delta value. Default on row creation is 0. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.9 | svrThrResetValue | 0 | 0 | This is the value that on all svrThrAlarmTypes except for equalTo, is used to reset the threshold. Default on row creation is 0 |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.10 | svrThrLastValue | 0 | 0 | Saved previous sample; needed to evaluate if alarm should be triggered or to evaluate delta values for threshold checking. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.11 | svrThrAlarmState | 0 | 0 | Whether this alarm is currently set or reset. This variable is used by polling management applications to determine if a thresho… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.12 | svrThrLogEvent | 0 | 0 | If yes, log to the system event log. Default value is False. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.13 | svrThrInvokeLocalHandler | 0 | 0 | If true, invoke a local alarm handler, passing trap structure. Mechanism is a local issue. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.14 | svrThrLocalHandlerPath | 0 | 0 | Pathname of local alarm handler. If not implemented, value will be null. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.15 | svrThrDescr | 0 | 0 | This attribute is used to describe the type of threshold. This is set by the management console not by the agent. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.16 | svrThrErrorValue | 0 | 0 | This is the SNMP defined error status which caused the svrThrStatus value to become equal to rowError. Only valid at that time. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.17 | svrThrComparisonName | 0 | 0 | An OID to a descriptor attribute which can be used with persistent to verify that the svrThrVariableName instance is correct. On… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.18 | svrThrComparisonValue | 0 | 0 | Data value of svrThrComparisonName - used when persistent is set. This value is compared to the current value on agent restarts.… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.19 | svrThrSeverity | 0 | 0 | Indicates the severity of the threshold. Default on row creation is informational. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.20 | svrThrTrapEnabler | 0 | 0 | Determines if a trap should be sent out if the threshold event does occur. If true, a trap will be sent out. If false, a trap wi… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.21 | svrThrLocalHandlerArguments1 | 0 | 0 | This is the first part of the argument line if the svrThrInvokeLocalHandler is used. This argument line is passed directly to the… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.22 | svrThrLocalHandlerArguments2 | 0 | 0 | Same semantics as svrThrLocalHandlerArguments1. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.23 | svrThrLocalHandlerArguments3 | 0 | 0 | Same semantics as svrThrLocalHandlerArguments1. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.24 | svrThrLocalHandlerArguments4 | 0 | 0 | Same semantics as svrThrLocalHandlerArguments1. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.25 | svrThrTrapsSendingInterval | 0 | 0 | Represents how often a trap should be sent if dealing with sending multiple traps per event. The units is minutes. Default value… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.26 | svrThrManagerDefinedTrapData | 0 | 0 | This is a string provided by a management console to be sent out with every trap. Default value on row creation is null. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.27 | svrThrUserDefinedTrapData | 0 | 0 | This is a string provided by a user via a management console to be sent out with every trap. Default value on row creation is nu… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.28 | svrThrRetryCount | 0 | 0 | Allows for a trap to be sent n number of sampling intervals after the threshold event occurred rather than right after the event… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.29 | svrThrResetType | 0 | 0 | Is this a greater than, greater than or equal to, equal to, less than or equal to, or less than the reset value? This variable wo… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.30 | svrThrAlarmCategory | 0 | 0 | A management station provided variable to allow for classification/grouping of thresholds. |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.31 | svrThrTrapOid | 0 | 0 | A fully defined OID of a svrmgt trap (other than reset and modify) that will be sent out when an event occurs. This OID will ove… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.32 | svrThrCreatedBy | 0 | 0 | Represents the creator of this threshold. This variable can be modified only during threshold creation. The default value on row… |
1.3.6.1.4.1.36.2.18.22.2.2.3.1.33 | svrThrModifiable | 0 | 0 | Determines whether modification of the threshold record is allowed after creation. If false, modification is allowed only during… |