Reference record for OID 1.3.6.1.4.1.36.2.18.30.1.9.2



parent
1.3.6.1.4.1.36.2.18.30.1.9 (decAtmTemperature)
node code
2
node name
decAtmTemperatureWarning
dot oid
1.3.6.1.4.1.36.2.18.30.1.9.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dec(36) ema(2) mib-extensions-1(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dec(36) ema(2) decMIBextension(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dec(36) ema(2) mib-extensions-1(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dec(36) ema(2) decMIBextension(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dec(36) ema(2) mib-extensions-1(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dec(36) ema(2) decMIBextension(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dec(36) ema(2) mib-extensions-1(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dec(36) ema(2) decMIBextension(18) decAtmChassisMIB(30) decAtmChassisMIBObjects(1) decAtmTemperature(9) decAtmTemperatureWarning(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/dec/ema/mib-extensions-1/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • /iso/identified-organization/dod/internet/private/enterprise/dec/ema/decMIBextension/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/dec/ema/mib-extensions-1/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • /iso/org/dod/internet/private/enterprise/dec/ema/decMIBextension/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • /iso/org/dod/internet/private/enterprises/dec/ema/mib-extensions-1/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • /iso/org/dod/internet/private/enterprises/dec/ema/decMIBextension/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dec/ema/mib-extensions-1/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dec/ema/decMIBextension/decAtmChassisMIB/decAtmChassisMIBObjects/decAtmTemperature/decAtmTemperatureWarning
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/36/2/18/30/1/9/2

    Description by mibdepot

    The value of this variable determines how the switch will
    respond to a condition of too high or too low cabinet
    temperature, or a condition of all fans being inoperative.
    If the value is 'heedWarning(1)', the system will be shut
    down when the temperature goes outside the designed limits
    or when too many of its fans become inoperative. If the
    value is 'ignoreWarning(2)', the system will continue to
    operate when either of these conditions occur.

    Setting this variable to 'ignoreWarning(2)' lets a manager
    cause a system that is too hot or too cold to continue to
    run. This setting will also allow the system to run while
    no fans are operative. Managers should note that this may
    be detrimental to the equipment.

    This object has a default value of 'heedWarning(1)'. Note
    that some switches may lack auto-shutdown capability; they
    will have a value of 'noWarningFeature(3) for this object.

    Parsed from file GSatm-Chassis.mib.V.txt
    Company: None
    Module: DEC-ATM-CHASSIS-MIB

    Description by circitor

    The value of this variable determines how the switch will
    respond to a condition of too high or too low cabinet
    temperature, or a condition of all fans being inoperative.
    If the value is 'heedWarning(1)', the system will be shut
    down when the temperature goes outside the designed limits
    or when too many of its fans become inoperative. If the
    value is 'ignoreWarning(2)', the system will continue to
    operate when either of these conditions occur.

    Setting this variable to 'ignoreWarning(2)' lets a manager
    cause a system that is too hot or too cold to continue to
    run. This setting will also allow the system to run while
    no fans are operative. Managers should note that this may
    be detrimental to the equipment.

    This object has a default value of 'heedWarning(1)'. Note
    that some switches may lack auto-shutdown capability; they
    will have a value of 'noWarningFeature(3) for this object.

    Parsed from file DEC-ATM-CHASSIS-MIB.mib
    Module: DEC-ATM-CHASSIS-MIB

    Information by oid_info

    Vendor: DEC
    Module: DEC-ATM-CHASSIS-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    decAtmTemperatureWarning OBJECT-TYPE SYNTAX INTEGER { heedWarning(1), ignoreWarning(2), noWarningFeature(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable determines how the switch will respond to a condition of too high or too low cabinet temperature, or a condition of all fans being inoperative. If the value is 'heedWarning(1)', the system will be shut down when the temperature goes outside the designed limits or when too many of its fans become inoperative. If the value is 'ignoreWarning(2)', the system will continue to operate when either of these conditions occur. Setting this variable to 'ignoreWarning(2)' lets a manager cause a system that is too hot or too cold to continue to run. This setting will also allow the system to run while no fans are operative. Managers should note that this may be detrimental to the equipment. This object has a default value of 'heedWarning(1)'. Note that some switches may lack auto-shutdown capability; they will have a value of 'noWarningFeature(3) for this object." ::= { decAtmTemperature 2 }

    Information by circitor

    decAtmTemperatureWarning OBJECT-TYPE SYNTAX INTEGER { heedWarning(1), ignoreWarning(2), noWarningFeature(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The value of this variable determines how the switch will respond to a condition of too high or too low cabinet temperature, or a condition of all fans being inoperative. If the value is 'heedWarning(1)', the system will be shut down when the temperature goes outside the designed limits or when too many of its fans become inoperative. If the value is 'ignoreWarning(2)', the system will continue to operate when either of these conditions occur. Setting this variable to 'ignoreWarning(2)' lets a manager cause a system that is too hot or too cold to continue to run. This setting will also allow the system to run while no fans are operative. Managers should note that this may be detrimental to the equipment. This object has a default value of 'heedWarning(1)'. Note that some switches may lack auto-shutdown capability; they will have a value of 'noWarningFeature(3) for this object." ::= { decAtmTemperature 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.36)

    Ron Bhanukitsiri

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.36.2.18.30.1.9.2.0 decAtmTemperatureWarning 0 0 None

    Brothers (2)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.36.2.18.30.1.9.1 decAtmCabinetTemperature 1 1 The cabinet temperature. Chassis types which do not have
    temperature sensors will always return 'noSensor(6)'.
    1.3.6.1.4.1.36.2.18.30.1.9.3 decAtmTemperatureLedProgram 1 1 The decAtmTemperatureLedProgram string is a sequence of
    instructions for the temperature LED state.

    The coding rules are as descr…