Reference record for OID 1.3.6.1.4.1.3881.2.2.0.2
- parent
- 1.3.6.1.4.1.3881.2.2.0 (alarmNotificationPrefix)
- node code
- 2
- node name
- alarmChanged
- dot oid
- 1.3.6.1.4.1.3881.2.2.0.2
- type
- NOTIFICATION-TYPE
- asn1 oid
-
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) ericssonIRP(3881) alarmIrpMIB(2) alarmNotifications(2) alarmNotificationPrefix(0) alarmChanged(2)}
- iri oid
-
- /iso/identified-organization/dod/internet/private/enterprise/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
- /iso/identified-organization/dod/internet/private/enterprises/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
- /iso/org/dod/internet/private/enterprise/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
- /iso/org/dod/internet/private/enterprises/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
- /iso/iso-identified-organization/dod/internet/private/enterprise/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
- /iso/iso-identified-organization/dod/internet/private/enterprises/ericssonIRP/alarmIrpMIB/alarmNotifications/alarmNotificationPrefix/alarmChanged
Description by circitor
This notification is generated when any of the
attributes of an Alarm has changed. Note that
the EventTime value in the notification will be
different than that in the original notifyNewAlarm
if and only if the alarmPerceivedSeverity value
is different from that carried in original
notifyNewAlarm.
Note that the notification does not include all
objects for the corresponding entry in the Alarm
Table. The reason is that some environments may have
problems with large PDUs. Thus, the notification
receiver must get the missing objects from the
Alarm Table.
Parsed from file ERICSSON-ALARM-IRP-MIB.mib
Module: ERICSSON-ALARM-IRP-MIB
Information by circitor
alarmChanged NOTIFICATION-TYPE
OBJECTS { notificationId,
alarmId,
alarmManagedObjectClass,
alarmManagedObjectInstance,
alarmEventTime,
alarmEventType,
alarmProbableCause,
alarmPerceivedSeverity,
alarmSpecificProblem }
STATUS current
DESCRIPTION
"This notification is generated when any of the
attributes of an Alarm has changed. Note that
the EventTime value in the notification will be
different than that in the original notifyNewAlarm
if and only if the alarmPerceivedSeverity value
is different from that carried in original
notifyNewAlarm.
Note that the notification does not include all
objects for the corresponding entry in the Alarm
Table. The reason is that some environments may have
problems with large PDUs. Thus, the notification
receiver must get the missing objects from the
Alarm Table."
::= { alarmNotificationPrefix 2 }
First Registration Authority (recovered by parent 1.3.6.1.4.1.3881)
Rahkonen Tomas
Brothers (2)
OID | Name | Sub children | Sub Nodes Total | Description |
1.3.6.1.4.1.3881.2.2.0.1 |
alarmNew |
0 |
0 |
This notification is sent when a new Alarm is generated and stored in the Alarm Table. Note that the notification does not includ… |
1.3.6.1.4.1.3881.2.2.0.3 |
alarmCleared |
0 |
0 |
This notification is generated when an alarm is cleared. A cleared alarm is removed from the Alarm Table and is no longer accessi… |