Reference record for OID 1.3.6.1.4.1.412.2.4.55.1.7



parent
1.3.6.1.4.1.412.2.4.55.1 (dMTFElectricalCurrentProbeEntry)
node code
7
node names
  • monitoredElectricalCurrentNormalMaximumAtt7
  • monitoredElectricalCurrentNormalMaximum
  • dot oid
    1.3.6.1.4.1.412.2.4.55.1.7
    type
    OBJECT-TYPE
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximumAtt7(7)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximum(7)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximumAtt7(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximum(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximumAtt7(7)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) dmtfSystemsMIF(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximum(7)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximumAtt7(7)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) dmtf(412) dmtfStdMifs(2) mapperdmtfGroups(4) dMTFElectricalCurrentProbeTable(55) dMTFElectricalCurrentProbeEntry(1) monitoredElectricalCurrentNormalMaximum(7)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/dmtf/dmtfStdMifs/dmtfSystemsMIF/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximumAtt7
  • /iso/identified-organization/dod/internet/private/enterprise/dmtf/dmtfStdMifs/dmtfSystemsMIF/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximum
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/dmtf/dmtfStdMifs/mapperdmtfGroups/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximumAtt7
  • /iso/org/dod/internet/private/enterprise/dmtf/dmtfStdMifs/mapperdmtfGroups/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximum
  • /iso/org/dod/internet/private/enterprises/dmtf/dmtfStdMifs/dmtfSystemsMIF/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximumAtt7
  • /iso/org/dod/internet/private/enterprises/dmtf/dmtfStdMifs/dmtfSystemsMIF/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximum
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dmtf/dmtfStdMifs/mapperdmtfGroups/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximumAtt7
  • /iso/iso-identified-organization/dod/internet/private/enterprises/dmtf/dmtfStdMifs/mapperdmtfGroups/dMTFElectricalCurrentProbeTable/dMTFElectricalCurrentProbeEntry/monitoredElectricalCurrentNormalMaximum
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/412/2/4/55/1/7

    Description by mibdepot

    The normal maximum electrical current reading of the current
    monitored by this probe in milliamps. 0x80000000 denotes 'unknown'.

    Parsed from file dellsys0.mib.txt
    Company: None
    Module: DELLSYS_MIB-MIB

    Description by circitor

    The normal maximum electrical current reading of the current
    monitored by this probe in milliamps. 0x80000000 denotes 'unknown'.

    Parsed from file DMTF-SYSTEMS-MIB.mib
    Module: DMTF-SYSTEMS-MIB

    Information by oid_info

    Vendor: Dell Inc.
    Module: BASEBRDD_MIB-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    monitoredElectricalCurrentNormalMaximumAtt7 OBJECT-TYPE SYNTAX DmiInteger ACCESS read-only STATUS mandatory DESCRIPTION "The normal maximum electrical current reading of the current monitored by this probe in milliamps. 0x80000000 denotes 'unknown'." REFERENCE "'DMTF|Electrical Current Probe|001' 7" ::= { dMTFElectricalCurrentProbeEntry 7 }

    Information by circitor

    monitoredElectricalCurrentNormalMaximum OBJECT-TYPE SYNTAX DmiInteger MAX-ACCESS read-only STATUS current DESCRIPTION "The normal maximum electrical current reading of the current monitored by this probe in milliamps. 0x80000000 denotes 'unknown'." REFERENCE "'DMTF|Electrical Current Probe|001' 7" ::= { dmtfElectricalCurrentProbeEntry 7 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.412)

    Williams Raymond C.

    Brothers (21)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.412.2.4.55.1.0 dMTFElectricalCurrentProbeState 0 0 "
    REFERENCE "'DMTF|Electrical Current Probe|001' 0
    1.3.6.1.4.1.412.2.4.55.1.1 electricalCurrentProbeTableIndexAtt1, electricalCurrentProbeTableIndex 0 0 Index into this electrical current probe table.
    1.3.6.1.4.1.412.2.4.55.1.2 electricalCurrentProbeLocationAtt2, electricalCurrentProbeLocation 0 0 Identifies the physical location of the electrical current
    probe.
    1.3.6.1.4.1.412.2.4.55.1.3 electricalCurrentProbeDescriptionAtt3, electricalCurrentProbeDescription 0 0 Additional descriptive information about the electrical current
    probe or probe's location.
    1.3.6.1.4.1.412.2.4.55.1.4 electricalCurrentStatusAtt4, electricalCurrentStatus 0 0 Defines the status of the electrical current monitored by
    this electrical current probe.
    1.3.6.1.4.1.412.2.4.55.1.5 electricalCurrentProbeReadingAtt5, electricalCurrentProbeReading 0 0 The present electrical current reading of this probe in milliamp
    . 0x8000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.6 monitoredElectricalCurrentNominalReadingAtt6, monitoredElectricalCurrentNominalReading 0 0 The nominal electrical current reading of the current monitored
    by this probe in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.8 monitoredElectricalCurrentNormalMinimumAtt8, monitoredElectricalCurrentNormalMinimum 0 0 The normal minimum electrical current reading of the current
    monitored by this probe in milliamps.0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.9 electricalCurrentProbeMaximumAtt9, electricalCurrentProbeMaximum 0 0 The maximum electrical current reading specified to be readable
    by this probe in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.10 electricalCurrentProbeMinimumAtt10, electricalCurrentProbeMinimum 0 0 The minimum electrical current reading specified to be readable
    by this probe in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.11 electricalCurrentReadingLowerThresholdNonCriticalAtt11, electricalCurrentReadingLowerThresholdNonCritical 0 0 The lower non-critical threshold for the electrical current
    reading set by the user, in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.12 electricalCurrentReadingUpperThresholdNonCriticalAtt12, electricalCurrentReadingUpperThresholdNonCritical 0 0 The upper non-critical threshold for the electrical current
    reading, in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.13 electricalCurrentReadingLowerThresholdCriticalAtt13, electricalCurrentReadingLowerThresholdCritical 0 0 The lower critical threshold for the electrical current probe,
    in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.14 currentReadingUpperThresholdCriticalAtt14, currentReadingUpperThresholdCritical 0 0 The upper critical threshold for the electrical current probe,
    in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.15 electricalCurrentReadingLowerThresholdNonRecoverabAtt15, electricalCurrentReadingLowerThresholdNonRecoverab 0 0 The lower non-recoverable threshold for the electrical current
    probe, in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.16 electricalCurrentReadingUpperThresholdNonRecoverabAtt16, electricalCurrentReadingUpperThresholdNonRecoverab 0 0 The upper non-recoverable threshold for the electrical current
    probe, in milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.17 electricalCurrentProbeResolutionAtt17, electricalCurrentProbeResolution 0 0 The resolution for the reading from this electrical current
    probe, in tenths of milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.18 electricalCurrentProbeToleranceAtt18, electricalCurrentProbeTolerance 0 0 The tolerance for the reading from this electrical current
    probe, in plus/minus milliamps. 0x80000000 denotes 'unknown'.
    1.3.6.1.4.1.412.2.4.55.1.19 electricalCurrentProbeAccuracyAtt19, electricalCurrentProbeAccuracy 0 0 The accuracy for the reading from this electrical current
    probe, in plus/minus hundredths of a percent. 0x80000000 denotes 'unknā€¦
    1.3.6.1.4.1.412.2.4.55.1.20 fRUGroupIndexAtt20 0 0 Index into the FRU table
    1.3.6.1.4.1.412.2.4.55.1.21 operationalGroupIndexAtt21 0 0 Index into the Operational State table