Number of changes to RM active state.
Parsed from file SN-OSM-PRIV-MIB.mib.txt
Company: None
Module: SN-OSM-PRIV-MIB
Number of changes to RM active state.
Parsed from file SN-OSM-PRIV-MIB.mib
Module: SN-OSM-PRIV-MIB
Vendor: Siemens AG Automation & Drives
Module: SN-OSM-PRIV-MIB
[Automatically extracted from oidview.com]
snOsmRmStateChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of changes to RM active state." DEFVAL { 0 } ::= { snOsm 13 }
snOsmRmStateChanges OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of changes to RM active state." DEFVAL { 0 } ::= { snOsm 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4196.1.1.2.100.2.1.13.0 | snOsmRmStateChanges | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4196.1.1.2.100.2.1.2 | snOsmFaultState | 1 | 1 | Indicates OSM/ESM fault state (state of fault LED/signaling contact). |
1.3.6.1.4.1.4196.1.1.2.100.2.1.3 | snOsmSignalledFaults | 1 | 1 | Number of signalled faults. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.4 | snOsmFaultValue | 1 | 1 | Fault value: 0 = no fault, bit 0 = power, bit 1 = linkdown, bit 2 = internal error, bit 3 = standby, bit 4 = rm, bit 5 … |
1.3.6.1.4.1.4196.1.1.2.100.2.1.5 | snOsmDigitalInputChange | 1 | 1 | Digital Input change |
1.3.6.1.4.1.4196.1.1.2.100.2.1.6 | snOsmDigitalInputState | 1 | 1 | Digital Input state |
1.3.6.1.4.1.4196.1.1.2.100.2.1.11 | snOsmRmMode | 1 | 1 | RM mode. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.12 | snOsmRmState | 1 | 1 | RM State. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.14 | snOsmRmObserverMode | 1 | 1 | Reserved for further use. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.21 | snOsmStandbyMode | 1 | 1 | Standby Mode. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.22 | snOsmStandbyPassiveState, snOsmStandbyState | 1 | 1 | Standby State. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.24 | snOsmStandbyCableState | 1 | 1 | Standby cable state. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.25 | snOsmStandbyStateChanges | 1 | 1 | Number of changes to standby active state. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.31 | snOsmPowerLineDown, snOsmPort7TestMac | 1 | 1 | MAC (source) address of test telegrams sent on port 7. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.32 | snOsmPowerLineUp, snOsmPort8TestMac | 1 | 1 | MAC (source) address of test telegrams sent on port 8. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.33 | snOsmMulticastTestMac | 1 | 1 | MAC multicast address used for redundancy functions. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.34 | snOsmMulticastLinkMac | 1 | 1 | MAC multicast address used for redundancy functions. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.35 | snOsmUnicastLinkMac | 1 | 1 | MAC unicast address used for redundancy functions. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.36 | snOsmMulticastSyncMac | 1 | 1 | MAC multicast address of time synchronisation packets. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.37 | snOsmMulticastFlowControlMac | 1 | 1 | MAC multicast address of flow control packets. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.38 | snOsmTestMaxDelay | 1 | 1 | Measured maximum delay of RM test telegrams. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.41 | snOsmFault, snOsmPowerSupply1State | 1 | 1 | State of power supply line 1. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.42 | snOsmPowerSupply2State | 1 | 1 | State of power supply line 2. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.43 | snOsmPowerSupply1Mask | 1 | 1 | Mask of power supply line 1. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.44 | snOsmPowerSupply2Mask | 1 | 1 | Mask of power supply line 2. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.45 | snOsmChangedPowerLine | 1 | 1 | The power line where the last Power-Up or -Down occurred. User can reset to initial value 0 at any time. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.51 | snOsmDigitalInput, snOsmResetCounters | 1 | 1 | Reset all counters of OSM protocol software. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.61 | snOsmPortTable | 1 | 7 | Table containing per-port objects in the form of private extensions of interface objects. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.62 | snOsmEventTable | 1 | 10 | Event configuration table. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.63 | snOsmDigitalInEventTable | 1 | 7 | Digital-In event configuration table. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.100 | snConfigId | 1 | 1 | OSM/ESM hardware type. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.101 | snSwitchFlowControl | 1 | 1 | Enable/Disable flow control functionality. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.102 | snSwitchSnifferSrc | 1 | 1 | Source port for traffic mirroring. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.103 | snSwitchSnifferDest | 1 | 1 | Destination port for traffic mirroring. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.104 | snSwitchSnifferEnable | 1 | 1 | Enable/Disable mirroring functionality. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.105 | snSwitchAgingEnable | 1 | 1 | Enable/Disable auto-aging functionality of the learning table. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.106 | snSwitchRmonMode | 1 | 1 | Enable/Disable RMon functionality (statistics, history, alarm, events). |
1.3.6.1.4.1.4196.1.1.2.100.2.1.107 | snSwitchFdbImagePollTime | 1 | 1 | Polling time for update of learning table image. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.108 | snSwitchLearningTableEntries | 1 | 1 | Number of entries in learning table image. |
1.3.6.1.4.1.4196.1.1.2.100.2.1.109 | snSwitchTimeToNextDataStore | 1 | 1 | snSwitchtimeToNextDataStore |
1.3.6.1.4.1.4196.1.1.2.100.2.1.110 | snSwitchFlushDataStore | 1 | 1 | Force direct saving of configuration data and log entries. |