Setting the value of this object to `save' causes the values
of the RoboExec Logging Level Group to be written out to the
current config file, which is stored in the
reLogLevelConfigFileName object. While the new ConfigFile is
being written, the value of this flag will be set to `saving'.
Any attempts to set the value while it is not `normal'
(i.e. the file is currently being written to the ConfigFile)
will result in a badValue error being returned. Setting the
value to `normal' will result in no action.
Parsed from file ROBOEXEC-RESOURCES-MIB.mib.txt
Company: None
Module: ROBOEXEC-RESOURCES-MIB
Setting the value of this object to `save' causes the values
of the RoboExec Logging Level Group to be written out to the
current config file, which is stored in the
reLogLevelConfigFileName object. While the new ConfigFile is
being written, the value of this flag will be set to `saving'.
Any attempts to set the value while it is not `normal'
(i.e. the file is currently being written to the ConfigFile)
will result in a badValue error being returned. Setting the
value to `normal' will result in no action.
Parsed from file ROBOEXEC-RESOURCES-MIB.mib
Module: ROBOEXEC-RESOURCES-MIB
Vendor: UTStarcom Incorporated
Module: ROBOEXEC-RESOURCES-MIB
[Automatically extracted from oidview.com]
usrreLogLevelCFMStatusFlag OBJECT-TYPE SYNTAX UsrConfigStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to `save' causes the values of the RoboExec Logging Level Group to be written out to the current config file, which is stored in the reLogLevelConfigFileName object. While the new ConfigFile is being written, the value of this flag will be set to `saving'. Any attempts to set the value while it is not `normal' (i.e. the file is currently being written to the ConfigFile) will result in a badValue error being returned. Setting the value to `normal' will result in no action." ::= { usrreEvents 2 }
usrreLogLevelCFMStatusFlag OBJECT-TYPE SYNTAX UsrConfigStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to `save' causes the values of the RoboExec Logging Level Group to be written out to the current config file, which is stored in the reLogLevelConfigFileName object. While the new ConfigFile is being written, the value of this flag will be set to `saving'. Any attempts to set the value while it is not `normal' (i.e. the file is currently being written to the ConfigFile) will result in a badValue error being returned. Setting the value to `normal' will result in no action." ::= { usrreEvents 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.4.3.3.2.0 | usrreLogLevelCFMStatusFlag | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.4.3.3.1 | usrreLogLevelConfigFileName | 1 | 1 | The name of a ConfigFile to read/write permanent database records. If the value of this object is an empty string, then the proce… |
1.3.6.1.4.1.429.4.3.3.3 | usrreLogLevelTable | 1 | 4 | The (conceptual) table of event log levels for the RoboExec. |
1.3.6.1.4.1.429.4.3.3.4 | usrreEvLocalFile | 1 | 1 | The file name of the local NVRAM logfile. |
1.3.6.1.4.1.429.4.3.3.5 | usrreEvOldLocalFile | 1 | 1 | The name of the file that the Event Handler should copy the old LocalFile contents to when the pilgrim system reboots. |
1.3.6.1.4.1.429.4.3.3.6 | usrreEvCriticalMsgsTable | 1 | 3 | The (conceptual) table of critical event messages. |
1.3.6.1.4.1.429.4.3.3.7 | usrreEvStatus | 1 | 1 | This switch allows disabling or enabling all logging of critical events to the local flash file system. This is disable by defaul… |