Setting the value of this object to 'save'
causes the values of the FR Base Group
entries to be written out to the current FR
configuration file. While the new configuration file
is being written, the FR process will set the value
of this flag set to 'saving'. Any attempts to set
the value while it is not 'normal' (i.e. the file
is currently being written to the config file)
will result in a badValue error being returned.
Setting the value to 'normal' will result in no
action.
Parsed from file USR-FR-EXT-MIB.mib.txt
Company: None
Module: USR-FR-EXT-MIB
Setting the value of this object to 'save'
causes the values of the FR Base Group
entries to be written out to the current FR
configuration file. While the new configuration file
is being written, the FR process will set the value
of this flag set to 'saving'. Any attempts to set
the value while it is not 'normal' (i.e. the file
is currently being written to the config file)
will result in a badValue error being returned.
Setting the value to 'normal' will result in no
action.
Parsed from file USR-FR-EXT-MIB.mib
Module: USR-FR-EXT-MIB
Vendor: UTStarcom Incorporated
Module: USR-FR-EXT-MIB
[Automatically extracted from oidview.com]
usrfrExtBaseCFMSaveStatus OBJECT-TYPE SYNTAX UsrConfigStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'save' causes the values of the FR Base Group entries to be written out to the current FR configuration file. While the new configuration file is being written, the FR process will set the value of this flag set to 'saving'. Any attempts to set the value while it is not 'normal' (i.e. the file is currently being written to the config file) will result in a badValue error being returned. Setting the value to 'normal' will result in no action." ::= { usrFRExt 2 }
usrfrExtBaseCFMSaveStatus OBJECT-TYPE SYNTAX UsrConfigStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Setting the value of this object to 'save' causes the values of the FR Base Group entries to be written out to the current FR configuration file. While the new configuration file is being written, the FR process will set the value of this flag set to 'saving'. Any attempts to set the value while it is not 'normal' (i.e. the file is currently being written to the config file) will result in a badValue error being returned. Setting the value to 'normal' will result in no action." ::= { usrFRExt 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.4.64.2.0 | usrfrExtBaseCFMSaveStatus | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.429.4.64.1 | usrfrExtBaseCfgFileName | 1 | 1 | The name of a Frame Relay ConfigFile to read/write permanent database records. If the value of this object is an empty string, th… |
1.3.6.1.4.1.429.4.64.3 | usrfrExtBaseConformanceOption | 1 | 1 | This variable indicates the Conformance Option of the Frame Relay Datalink. |
1.3.6.1.4.1.429.4.64.4 | usrfrExtDlcmiTable | 1 | 7 | The Parameters for the Data Link Connection Management Interface for the frame relay service on this interface. |
1.3.6.1.4.1.429.4.64.5 | usrfrExtCircuitTable | 1 | 37 | A table containing information about specific virtual circuits. |
1.3.6.1.4.1.429.4.64.6 | usrfrExtErrTable | 1 | 38 | A table containing information about Errors on the Frame Relay interface. |
1.3.6.1.4.1.429.4.64.7 | usrfrExtTraps | 2 | 2 | None |
1.3.6.1.4.1.429.4.64.8 | usrfrExtPTMPGroupTable | 1 | 31 | A table containing information about PTMP PVC Group specific |