This table is used to provide remote device monitoring facilities.
This table allows a list of network devices to be set up
and polled regularly (or only once) by a variety of protocols.
The table can be configured to inform the management station(s)
of devices that are not responding to polls or that have started
to respond after a period of silence.
The minimum effort required to do a single poll is
1. In one packet, Write the address, rate=once-only(1) and
RowStatus=CreateAndGo.
2. In the next packet, read the roundTripTime.
The minimum effort required to monitor a device is
1. In one packet, Write the address, rate=every-30-seconds(1) and
RowStatus=CreateAndGo.
2. Wait for traps to come in.
Parsed from file lbhub-fms.mib.txt
Company: None
Module: LBHUB-FMS-MIB
This table is used to provide remote device monitoring facilities.
This table allows a list of network devices to be set up
and polled regularly (or only once) by a variety of protocols.
The table can be configured to inform the management station(s)
of devices that are not responding to polls or that have started
to respond after a period of silence.
The minimum effort required to do a single poll is
1. In one packet, Write the address, rate=once-only(1) and
RowStatus=CreateAndGo.
2. In the next packet, read the roundTripTime.
The minimum effort required to monitor a device is
1. In one packet, Write the address, rate=every-30-seconds(1) and
RowStatus=CreateAndGo.
2. Wait for traps to come in.
Parsed from file LBHUB-MSH-MIB.mib
Module: LBHUB-MSH-MIB
Vendor: 3Com
Module: A3COM0018-REMOTE-POLL (A3COM0018-REMOTE-POLL.mib)
Type: TABLE
Access: not-accessible
Syntax: SEQUENCE OF
Automatically extracted from www.mibdepot.com
pollTable OBJECT-TYPE SYNTAX SEQUENCE OF PollTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to provide remote device monitoring facilities. This table allows a list of network devices to be set up and polled regularly (or only once) by a variety of protocols. The table can be configured to inform the management station(s) of devices that are not responding to polls or that have started to respond after a period of silence. The minimum effort required to do a single poll is 1. In one packet, Write the address, rate=once-only(1) and RowStatus=CreateAndGo. 2. In the next packet, read the roundTripTime. The minimum effort required to monitor a device is 1. In one packet, Write the address, rate=every-30-seconds(1) and RowStatus=CreateAndGo. 2. Wait for traps to come in." ::= { poll 1 }
pollTable OBJECT-TYPE SYNTAX SEQUENCE OF PollTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table is used to provide remote device monitoring facilities. This table allows a list of network devices to be set up and polled regularly (or only once) by a variety of protocols. The table can be configured to inform the management station(s) of devices that are not responding to polls or that have started to respond after a period of silence. The minimum effort required to do a single poll is 1. In one packet, Write the address, rate=once-only(1) and RowStatus=CreateAndGo. 2. In the next packet, read the roundTripTime. The minimum effort required to monitor a device is 1. In one packet, Write the address, rate=every-30-seconds(1) and RowStatus=CreateAndGo. 2. Wait for traps to come in." ::= { poll 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.10.20.1.1 | pollTableEntry | 11 | 11 | A table used to define device monitoring. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.43.10.20.2 | pollNextFreeIndex | 1 | 1 | Indicates the the next value of pollIndex which can be used to create the next poll entry. This value is set to zero if there areā¦ |