Reference record for OID 1.3.6.1.4.1.43.10.5.8


parent
1.3.6.1.4.1.43.10.5 (gauges)
node code
8
node name
gaugeConfigureValue
dot oid
1.3.6.1.4.1.43.10.5.8
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) a3Com(43) generic(10) gauges(5) gaugeConfigureValue(8)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/a3Com/generic/gauges/gaugeConfigureValue
  • /iso/identified-organization/dod/internet/private/enterprises/a3Com/generic/gauges/gaugeConfigureValue
  • /iso/org/dod/internet/private/enterprise/a3Com/generic/gauges/gaugeConfigureValue
  • /iso/org/dod/internet/private/enterprises/a3Com/generic/gauges/gaugeConfigureValue
  • /iso/iso-identified-organization/dod/internet/private/enterprise/a3Com/generic/gauges/gaugeConfigureValue
  • /iso/iso-identified-organization/dod/internet/private/enterprises/a3Com/generic/gauges/gaugeConfigureValue
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/43/10/5/8

    Description by mibdepot

    Value to be written to the 'gaugeConfigureColumn' of the
    Alarms which match the 'gaugeConfigureObjId'. Writing to this
    value initiates the operation.

    Parsed from file msh100.mib.txt
    Company: None
    Module: LBMSH-MIB

    Description by circitor

    Value to be written to the 'gaugeConfigureColumn' of the
    Alarms which match the 'gaugeConfigureObjId'. Writing to this
    value initiates the operation.

    Parsed from file LBHUB-MSH-MIB.mib
    Module: LBHUB-MSH-MIB

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    gaugeConfigureValue OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS write-only STATUS mandatory DESCRIPTION "Value to be written to the 'gaugeConfigureColumn' of the Alarms which match the 'gaugeConfigureObjId'. Writing to this value initiates the operation." ::= { gauges 8 }

    Information by circitor

    gaugeConfigureValue OBJECT-TYPE SYNTAX INTEGER (1..4294967295) ACCESS write-only STATUS mandatory DESCRIPTION "Value to be written to the 'gaugeConfigureColumn' of the Alarms which match the 'gaugeConfigureObjId'. Writing to this value initiates the operation." ::= { gauges 8 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.43)

    Jeremy Siegel

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.43.10.5.8.0 gaugeConfigureValue 0 0 None

    Brothers (8)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.43.10.5.1 gaugeTable 1 14 A table used to define Alarms.
    1.3.6.1.4.1.43.10.5.2 gaugeTableSize 1 1 Number of entries in Alarm Table. The size of the Alarm Table
    depends on the requirements and available resources of the
    device. …
    1.3.6.1.4.1.43.10.5.3 gaugeThresholdLevelScaler 1 1 The ThresholdLevel is set to this percentage of the peakValue
    when the Alarm is auto-calibrated.

    e.g gaugeThresholdLevelScaler = …
    1.3.6.1.4.1.43.10.5.4 gaugeRecoveryLevelScaler 1 1 The RecoveryLevel is set to this percentage of the peakValue
    when the Alarm is auto-calibrated.

    e.g gaugeRecoveryLevelScaler = 90…
    1.3.6.1.4.1.43.10.5.5 gaugeTableUpdate 1 1 Performs the specified operation on every Alarm in the table.
    1.3.6.1.4.1.43.10.5.6 gaugeConfigureObjId 1 1 Object Id and qualifier of alarm(s) to be updated.
    1.3.6.1.4.1.43.10.5.7 gaugeConfigureColumn 1 1 Alarm Table Column to be updated.
    1.3.6.1.4.1.43.10.5.9 gaugeNextFreeIndex 1 1 Indicates the gaugeIndex which must be used to create the
    next alarm. Index is set to GAUGE_TABLE_FULL (zero) if
    there are no fre…