For a WAN Bridge Link which (potentially) has
the same value of dot1dBasePortIfIndex as another
WAN Bridge Link on the same bridge, this object
contains the name of an object instance unique
to this WAN Bridge Link. For example, in the
case where multiple ports correspond one-to-one
with multiple X.25 virtual circuits, this value
might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.
For a WAN Bridge Link which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }.
Not Supported, will return zero
Parsed from file vanguard-65xx-bridge.mib.txt
Company: None
Module: BRIDGE-OPT-MIB
For a WAN Bridge Link which (potentially) has
the same value of dot1dBasePortIfIndex as another
WAN Bridge Link on the same bridge, this object
contains the name of an object instance unique
to this WAN Bridge Link. For example, in the
case where multiple ports correspond one-to-one
with multiple X.25 virtual circuits, this value
might identify an (e.g., the first) object
instance associated with the X.25 virtual circuit
corresponding to this port.
For a WAN Bridge Link which has a unique value of
dot1dBasePortIfIndex, this object can have the
value { 0 0 }.
Not Supported, will return zero
Parsed from file BRIDGE-OPT-MIB.mib
Module: BRIDGE-OPT-MIB
Vendor: Codex
Module: BRIDGE-OPT-MIB
[Automatically extracted from oidview.com]
cdx6500LfcmBaseLinkCircuit OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "For a WAN Bridge Link which (potentially) has the same value of dot1dBasePortIfIndex as another WAN Bridge Link on the same bridge, this object contains the name of an object instance unique to this WAN Bridge Link. For example, in the case where multiple ports correspond one-to-one with multiple X.25 virtual circuits, this value might identify an (e.g., the first) object instance associated with the X.25 virtual circuit corresponding to this port. For a WAN Bridge Link which has a unique value of dot1dBasePortIfIndex, this object can have the value { 0 0 }. Not Supported, will return zero" ::= { cdx6500PSTBaseLinkEntry 3 }
cdx6500LfcmBaseLinkCircuit OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "For a WAN Bridge Link which (potentially) has the same value of dot1dBasePortIfIndex as another WAN Bridge Link on the same bridge, this object contains the name of an object instance unique to this WAN Bridge Link. For example, in the case where multiple ports correspond one-to-one with multiple X.25 virtual circuits, this value might identify an (e.g., the first) object instance associated with the X.25 virtual circuit corresponding to this port. For a WAN Bridge Link which has a unique value of dot1dBasePortIfIndex, this object can have the value { 0 0 }. Not Supported, will return zero" ::= { cdx6500PSTBaseLinkEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.449.2.1.3.1.5.4.1.1 | cdx6500LfcmBaseLink | 0 | 0 | This object is the WAN Bridge Link number for control and statistics. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.2 | cdx6500LfcmBaseLinkIfIndex | 0 | 0 | The value of the instance of the ifIndex object, for the interface corresponding to this WAN Bridge Link. Not Supported, will ret… |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.4 | cdx6500LfcmBaseLinkBlStatus | 0 | 0 | The status of the WAN Brdige Link: configErr = Configuration error on link swDisabled = Physical errors on link userDisabled … |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.5 | cdx6500LfcmBaseLinkClearStats | 0 | 0 | This is the command to reset the LAN port bridge statistics. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.6 | cdx6500LfcmBaseLinkLastStatReset | 0 | 0 | The time of the last LAN port statistics reset. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.7 | cdx6500LfcmLinkBridgeLinkBoot | 0 | 0 | This is the command to boot the WAN Bridge Link parameters. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.8 | cdx6500LfcmLinkBlEnable | 0 | 0 | This is the command to Enable the WAN Bridge Link. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.9 | cdx6500LfcmLinkBlDisable | 0 | 0 | This is the command to Disable the WAN Bridge Link. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.10 | cdx6500LfcmCtrlsLinkSetLinkProt | 0 | 0 | This is a command to set Unicast Protection for the WAN Bridge Link. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.11 | cdx6500LfcmCtrlsLinkClrLinkProt | 0 | 0 | This is a command to clear Unicast Protection for the WAN Bridge Link. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.12 | cdx6500LfcmCtrlsLinkSetMultProt | 0 | 0 | This is a command to set Multicast Protection for the WAN Bridge Link. |
1.3.6.1.4.1.449.2.1.3.1.5.4.1.13 | cdx6500LfcmCtrlsLinkClrMultProt | 0 | 0 | This is a command to clear Multicast Protection for the WAN Bridge Link. |