devices.
Sources for this description
Cisco
Source file: Download DOCS-IF-M-CMTS-MIB.my · Publisher's file
MIBdepot
Source file: Download DOCS-IF-M-CMTS-MIB.my.txt
OID reference
1.3.6.1.4.1.4491.2.1.6.2.1.2
The compliance statement for M-CMTS EQAM compliant devices.
Identification
{1 3 6 1 4 1 4491 2 1 6 2 1 2}
Meaning
Identical descriptions are grouped. Different wording and device-specific notes are retained.
Source file: Download DOCS-IF-M-CMTS-MIB.my · Publisher's file
Source file: Download DOCS-IF-M-CMTS-MIB.my.txt
Historical records
Source file: Download DOCS-IF-M-CMTS-MIB-V1SMI.my · Publisher's file
Source file: Download DOCS-IF-M-CMTS-MIB-V1SMI.my.txt
docsIfMCmtsEQAMCompliance OBJECT IDENTIFIER ::= { docsIfMCmtsCompliances 2 }
docsIfMCmtsEQAMCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for M-CMTS EQAM compliant
devices."
MODULE
MANDATORY-GROUPS {
docsIfMCmtsBaseGroup,
docsIfMCmtsEqamDevGroup,
entityPhysicalGroup,
entityPhysical2Group,
entityPhysical3Group,
entityGeneralGroup
}
GROUP entityLogical2Group
DESCRIPTION
"Implementation of this group is not mandatory for Agents
that model all MIB object instances within a
single naming scope."
GROUP entityMappingGroup
DESCRIPTION
"Implementation of the entPhysicalContainsTable is
mandatory for EQAMs. Implementation of the
entLPMappingTable and entAliasMappingTable are required
for agents with MIB object
instances within multiple logical entities. EQAM devices
with MIB object instances in a single naming scope SHOULD
implement entAliasMappingTable by using
entAliasLogicalIndexOrZero set to zero."
OBJECT entPhysicalSerialNum
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required for agents that
cannot identify serial number information for physical
entities, and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
physical entities for which the associated value of the
entPhysicalIsFRU object is equal to 'false(2)'."
OBJECT entPhysicalAlias
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only if the associated
entPhysicalClass value is equal to 'chassis(3)'."
OBJECT entPhysicalAssetID
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required for agents that
cannot provide non-volatile storage for NMS-assigned asset
identifiers.
Write access is not required for physical entities for which
the associated value of entPhysicalIsFRU is equal to
'false(2)'."
OBJECT entPhysicalClass
SYNTAX INTEGER {
other(1),
unknown(2),
chassis(3),
backplane(4),
container(5),
powerSupply(6),
fan(7),
sensor(8),
module(9),
port(10),
stack(11)
}
DESCRIPTION
"Implementation of the 'cpu(12)' enumeration is not
required."
::= { docsIfMCmtsCompliances 2 }
docsIfMCmtsEQAMCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for M-CMTS EQAM compliant
devices."
MODULE
MANDATORY-GROUPS {
docsIfMCmtsBaseGroup,
docsIfMCmtsEqamDevGroup,
entityPhysicalGroup,
entityPhysical2Group,
entityPhysical3Group,
entityGeneralGroup
}
GROUP entityLogical2Group
DESCRIPTION
"Implementation of this group is not mandatory for Agents
that model all MIB object instances within a
single naming scope."
GROUP entityMappingGroup
DESCRIPTION
"Implementation of the entPhysicalContainsTable is
mandatory for EQAMs. Implementation of the
entLPMappingTable and entAliasMappingTable are required
for agents with MIB object
instances within multiple logical entities. EQAM devices
with MIB object instances in a single naming scope SHOULD
implement entAliasMappingTable by using
entAliasLogicalIndexOrZero set to zero."
OBJECT entPhysicalSerialNum
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required for agents that
cannot identify serial number information for physical
entities, and/or cannot provide non-volatile storage for
NMS-assigned serial numbers.
Write access is not required for agents that can identify
serial number information for physical entities but cannot
provide non-volatile storage for NMS-assigned serial
numbers.
Write access is not required for physical entities for
physical entities for which the associated value of the
entPhysicalIsFRU object is equal to 'false(2)'."
OBJECT entPhysicalAlias
MIN-ACCESS read-only
DESCRIPTION
"Write access is required only if the associated
entPhysicalClass value is equal to 'chassis(3)'."
OBJECT entPhysicalAssetID
MIN-ACCESS not-accessible
DESCRIPTION
"Read and write access is not required for agents that
cannot provide non-volatile storage for NMS-assigned asset
identifiers.
Write access is not required for physical entities for which
the associated value of entPhysicalIsFRU is equal to
'false(2)'."
OBJECT entPhysicalClass
SYNTAX INTEGER {
other(1),
unknown(2),
chassis(3),
backplane(4),
container(5),
powerSupply(6),
fan(7),
sensor(8),
module(9),
port(10),
stack(11)
}
DESCRIPTION
"Implementation of the 'cpu(12)' enumeration is not
required."
::= { docsIfMCmtsCompliances 2 }
Registration
| OID | Name | Direct children | Descendants | Description |
|---|---|---|---|---|
| 1.3.6.1.4.1.4491.2.1.6.2.1.1 | docsIfMCmtsCoreDeviceCompliance | 0 | 0 | The compliance statement for M-CMTS Core compliant devices. |