cabhCdpSetToFactory OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to true(1) causes the DHCP default options to be returned back to factory defaults
and all current mappings to use the factory default settings at the next lease renewal time. Reading this object
always returns false(2). When cabhCdpSetToFactory is set to true, the following actions occur: 1. Reset all
default CDS DHCP options to the factory defaults. 2. The CDS will offer the factory default DHCP options
at the next lease renewal time.
The objects set to factory defaults are:
cabhCdpLanTransThreshold,
cabhCdpLanTransAction,
cabhCdpWanDataIpAddrCount,
cabhCdpLanStartType,
cabhCdpLanPoolStart,
cabhCdpLanPoolEndType,
cabhCdpLanPoolEnd,
cabhCdpNetworkNumber,
cabhCdpServerSubnetMaskType,
cabhCdpServerSubnetMask,
cabhCdpServerTimeOffset,
cabhCdpServerRouterType,
cabhCdpServerRouter,
cabhCdpServerDnsAddressType,
cabhCdpServerDnsAddress,
cabhCdpServerSyslogAddressType,
cabhCdpServerSyslogAddress,
cabhCdpServerDomainName,
cabhCdpServerTTL,
cabhCdpServerInterfaceMTU,
cabhCdpServerVendorSpecific,
cabhCdpServerLeaseTime,
cabhCdpServerDhcpAddressType,
cabhCdpServerDhcpAddress"
REFERENCE
""
View at oid-info.com
Reading this object always returns false(2). When the
cabhCdpSetToFactory object is set to true(1), the PS must
take the following actions:
1. Clear all cabhCdpLanAddrEntries in the CDP LAN Address
Table.
2. The CDS must offer the factory default DHCP options
at the next lease renewal time.
3. Reset the following objects to their factory default
values:
cabhCdpLanTransThreshold,
cabhCdpLanTransAction,
cabhCdpWanDataIpAddrCount,
cabhCdpTimeOffsetSelection,
cabhCdpSnmpSetTimeOffset,
cabhCdpDaylightSavingTimeEnable,
cabhCdpLanPoolStartType,
cabhCdpLanPoolStart,
cabhCdpLanPoolEndType,
cabhCdpLanPoolEnd,
cabhCdpServerNetworkNumberType,
cabhCdpServerNetworkNumber,
cabhCdpServerSubnetMaskType,
cabhCdpServerSubnetMask,
cabhCdpServerTimeOffset,
cabhCdpServerRouterType,
cabhCdpServerRouter,
cabhCdpServerDnsAddressType,
cabhCdpServerDnsAddress,
cabhCdpServerSyslogAddressType,
cabhCdpServerSyslogAddress,
cabhCdpServerDomainName,
cabhCdpServerTTL,
cabhCdpServerInterfaceMTU,
cabhCdpServerVendorSpecific,
cabhCdpServerLeaseTime,
cabhCdpServerDhcpAddressType,
cabhCdpServerDhcpAddress,
cabhCdpServerCommitStatus
Parsed from file CABH-CDP-MIB.mib
Module: CABH-CDP-MIB
Automatically extracted from Rec. ITU-T J.191
cabhCdpSetToFactory OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Reading this object always returns false(2). When the cabhCdpSetToFactory object is set to true(1), the PS must take the following actions: 1. Clear all cabhCdpLanAddrEntries in the CDP LAN Address Table. 2. The CDS must offer the factory default DHCP options at the next lease renewal time. 3. Reset the following objects to their factory default values: cabhCdpLanTransThreshold, cabhCdpLanTransAction, cabhCdpWanDataIpAddrCount, cabhCdpTimeOffsetSelection, cabhCdpSnmpSetTimeOffset, cabhCdpDaylightSavingTimeEnable, cabhCdpLanPoolStartType, cabhCdpLanPoolStart, cabhCdpLanPoolEndType, cabhCdpLanPoolEnd, cabhCdpServerNetworkNumberType, cabhCdpServerNetworkNumber, cabhCdpServerSubnetMaskType, cabhCdpServerSubnetMask, cabhCdpServerTimeOffset, cabhCdpServerRouterType, cabhCdpServerRouter, cabhCdpServerDnsAddressType, cabhCdpServerDnsAddress, cabhCdpServerSyslogAddressType, cabhCdpServerSyslogAddress, cabhCdpServerDomainName, cabhCdpServerTTL, cabhCdpServerInterfaceMTU, cabhCdpServerVendorSpecific, cabhCdpServerLeaseTime, cabhCdpServerDhcpAddressType, cabhCdpServerDhcpAddress, cabhCdpServerCommitStatus" ::= { cabhCdpBase 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4491.2.4.4.1.1.2 | cabhCdpLanTransCurCount | 0 | 0 | cabhCdpLanTransCurCount OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current number of LA… |
1.3.6.1.4.1.4491.2.4.4.1.1.3 | cabhCdpLanTransThreshold | 0 | 0 | The threshold number of LAN-Trans IP addresses allocated or assigned above which the PS generates an alarm condition. Whenever an… |
1.3.6.1.4.1.4491.2.4.4.1.1.4 | cabhCdpLanTransAction | 0 | 0 | The action taken when the CDS assigns a LAN-Trans address and the number of LAN-Trans addresses assigned (cabhCdpLanTransCurCount… |
1.3.6.1.4.1.4491.2.4.4.1.1.5 | cabhCdpWanDataIpAddrCount | 0 | 0 | cabhCdpWanDataIpAddrCount OBJECT-TYPE SYNTAX INTEGER ( 0..63 ) MAX-ACCESS read-write STATUS current DESCRIPTION "This is the nu… |
1.3.6.1.4.1.4491.2.4.4.1.1.6 | cabhCdpLastSetToFactory | 0 | 0 | The value of sysUpTime when cabhCdpSetToFactory was last set to true. Zero if never reset. |
1.3.6.1.4.1.4491.2.4.4.1.1.7 | cabhCdpTimeOffsetSelection | 0 | 0 | This object selects the source to be used by the PS in determining the time offset to the time of day acquired from the time serv… |
1.3.6.1.4.1.4491.2.4.4.1.1.8 | cabhCdpSnmpSetTimeOffset | 0 | 0 | This object is intended to be used in cases where the service provider's provisioning system serves devices in multiple time zone… |
1.3.6.1.4.1.4491.2.4.4.1.1.9 | cabhCdpDaylightSavingTimeEnable | 0 | 0 | This object allows a manager to configure the PS to adjust the current time of day based on Daylight Saving Time. If the value of… |