The port on the concentrator that the SynOptics'
Hello PDU was received from the bridge. The value
zero is used to indicate that the bridge does not
transmit SynOptics' Hello PDUs or the port from
which the message was received can not be
determined.
Parsed from file s3tok430.mib.txt
Company: nortel
Module: SYNOPTICS-TOKENRING-MIB
Vendor: Nortel Networks
Module: SYNOPTICS-TOKENRING-MIB (s3tok430.mib)
Type: TABULAR
Access: read-only
Syntax: INTEGER
Automatically extracted from www.mibdepot.com
s3TrTopBrEntPortNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port on the concentrator that the SynOptics' Hello PDU was received from the bridge. The value zero is used to indicate that the bridge does not transmit SynOptics' Hello PDUs or the port from which the message was received can not be determined." ::= { s3TrTopBridgeEntry 9 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.45.1.3.3.6.2.1.1 | s3TrTopBrEntBrNum | 0 | 0 | The bridge's bridge number as defined in the IEEE 802.5 spec. |
1.3.6.1.4.1.45.1.3.3.6.2.1.2 | s3TrTopBrEntOwnRingNum | 0 | 0 | Ring number for this master NMM. |
1.3.6.1.4.1.45.1.3.3.6.2.1.3 | s3TrTopBrEntAdjRingNum | 0 | 0 | Ring number of the adjacent ring that is joined by the bridge. |
1.3.6.1.4.1.45.1.3.3.6.2.1.4 | s3TrTopBrEntAdjMasterNmmIpAddr | 0 | 0 | IP address of the adjacent master NMM. The value for this object is 0.0.0.0 when the bridge generates a SynOptics Hello PDU and t… |
1.3.6.1.4.1.45.1.3.3.6.2.1.5 | s3TrTopBrEntMacAddr | 0 | 0 | The MAC address of the bridge port sending the SynOptics' Hello PDU. The value is 00:00:00:00:00:00 if the bridge does not trans… |
1.3.6.1.4.1.45.1.3.3.6.2.1.6 | s3TrTopBrEntIpAddr | 0 | 0 | IP address of the bridge sending the SynOptics' Hello PDU. The value is 0.0.0.0 if the bridge does not transmit SynOptics' Hello … |
1.3.6.1.4.1.45.1.3.3.6.2.1.7 | s3TrTopBrEntType | 0 | 0 | The kind of bridge this entry represents. The values come from the SynOptics' Hello PDUs generated by the bridge. The values are:… |
1.3.6.1.4.1.45.1.3.3.6.2.1.8 | s3TrTopBrEntSlotNum | 0 | 0 | The slot on the concentrator that the SynOptics' Hello PDU was received from the bridge. The value zero is used to indicate that … |
1.3.6.1.4.1.45.1.3.3.6.2.1.10 | s3TrTopBrEntNumPort | 0 | 0 | Total number of Ports installed on the bridge. The value zero is used to indicate that the bridge does not transmit SynOptics' H… |
1.3.6.1.4.1.45.1.3.3.6.2.1.11 | s3TrTopBrEntHelloPortNum | 0 | 0 | The port on the bridge from which the Hello PDU was sent. The value zero is used to indicate that the bridge does not transmit Sy… |
1.3.6.1.4.1.45.1.3.3.6.2.1.12 | s3TrTopBrEntHelloPortStatus | 0 | 0 | The status of the port on Bridge from which the SynOptics' Hello PDU was sent. The value are: other(1).............bridge does no… |
1.3.6.1.4.1.45.1.3.3.6.2.1.13 | s3TrTopBrEntMonPortStatus | 0 | 0 | The status of the 'monitor' port on Bridge from which the SynOptics' Hello PDU was sent. The values are: other(1)..............br… |