Destination Point Code (The Integer Value).
The Point Code should be converted into its Integer
equivalent. For Example:
0-1-1 is converted as 257 (for ANSI)
0-1-2 is converted as 10 (for ITU)
Parsed from file A2000.mib.txt
Company: None
Module: ARMILLAIRE2000-MIB
Destination Point Code (The Integer Value).
The Point Code should be converted into its Integer
equivalent. For Example:
0-1-1 is converted as 257 (for ANSI)
0-1-2 is converted as 10 (for ITU)
Parsed from file ARMILLAIRE2000-MIB.mib
Module: ARMILLAIRE2000-MIB
Vendor: ARMILLAIRE TECHNOLOGIES
Module: ARMILLAIRE2000-MIB
[Automatically extracted from oidview.com]
ss7CktTmrDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CicTmrEntry 1 }
ss7CktTmrDpc OBJECT-TYPE SYNTAX INTEGER(1..16777215) ACCESS read-write STATUS mandatory DESCRIPTION "Destination Point Code (The Integer Value). The Point Code should be converted into its Integer equivalent. For Example: 0-1-1 is converted as 257 (for ANSI) 0-1-2 is converted as 10 (for ITU) " ::= { ss7CicTmrEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.2 | ss7CktTmrCic | 0 | 0 | Circuit identifier code. Can be any integer 1-65535. |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.3 | ss7CktTmrT3 | 0 | 0 | T3 timer. Default Value is 0 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.4 | ss7CktTmrT12 | 0 | 0 | T12 timer - blocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.5 | ss7CktTmrT13 | 0 | 0 | T13 timer - initial blocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.6 | ss7CktTmrT14 | 0 | 0 | T14 timer - unblocking sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.7 | ss7CktTmrT15 | 0 | 0 | T15 timer - initial unblocking sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.8 | ss7CktTmrT16 | 0 | 0 | T16 timer - reset sent. Default Value is 40 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.9 | ss7CktTmrT17 | 0 | 0 | T17 timer - initial reset sent. Default Value is 600 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.10 | ss7CktTmrTVal | 0 | 0 | TVal timer - initial reset sent. Default Value is 100 milliSeconds |
1.3.6.1.4.1.4618.1.2.2.1.2.3.1.11 | ss7CktTmrRowStatus | 0 | 0 | This is a command to MODIFY a Timer. A 'GET' operation on this object will display the default value [no action]. The possible op… |