Count of CRC errors detected on an ESF framed circuit.
In ESF framing a CRC is generated at the source, based upon
the composite data. A CRC error indicates the presence of
at least one bit error in an ESF superframe. This field is
a free-running accumulation of CRC errors and IS NOT reset
when the current 15 minute interval expires. It can be reset
with the performance command ty3250T1PerfClearEvents.
Not applicable if D4/SF framing is selcted.
Parsed from file tylink-3250.mib.txt
Company: None
Module: TY3250I-MIB
Count of CRC errors detected on an ESF framed circuit.
In ESF framing a CRC is generated at the source, based upon
the composite data. A CRC error indicates the presence of
at least one bit error in an ESF superframe. This field is
a free-running accumulation of CRC errors and IS NOT reset
when the current 15 minute interval expires. It can be reset
with the performance command ty3250T1PerfClearEvents.
Not applicable if D4/SF framing is selcted.
Parsed from file TY3250I-MIB.mib
Module: TY3250I-MIB
Vendor: Tylink
Module: TY3250I-MIB
[Automatically extracted from oidview.com]
ty3250T1CurrentCrc6Events OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of CRC errors detected on an ESF framed circuit. In ESF framing a CRC is generated at the source, based upon the composite data. A CRC error indicates the presence of at least one bit error in an ESF superframe. This field is a free-running accumulation of CRC errors and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents. Not applicable if D4/SF framing is selcted." ::= { ty3250T1CurrentEntry 2 }
ty3250T1CurrentCrc6Events OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Count of CRC errors detected on an ESF framed circuit. In ESF framing a CRC is generated at the source, based upon the composite data. A CRC error indicates the presence of at least one bit error in an ESF superframe. This field is a free-running accumulation of CRC errors and IS NOT reset when the current 15 minute interval expires. It can be reset with the performance command ty3250T1PerfClearEvents. Not applicable if D4/SF framing is selcted." ::= { ty3250T1CurrentEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.466.4.14.1.1 | ty3250T1CurrentIndex | 0 | 0 | The index value which uniquely identifies the T1 interface to which this entry is applica- ble. |
1.3.6.1.4.1.466.4.14.1.3 | ty3250T1CurrentOofEvents | 0 | 0 | Count of Out-of-Frame events on a T1 circuit. An out-of- frame event occurs when the frame synchronization criteria is lost and a… |
1.3.6.1.4.1.466.4.14.1.4 | ty3250T1CurrentESs | 0 | 0 | The number of Errored Seconds, encountered by a T1 interface in the current 15 minute inter- val. An errored second is a one-sec… |
1.3.6.1.4.1.466.4.14.1.5 | ty3250T1CurrentSESs | 0 | 0 | The number of Severely Errored Seconds encoun- tered by a t1 interface in the current 15 minute interval. A severely errored … |
1.3.6.1.4.1.466.4.14.1.6 | ty3250T1CurrentSEFSs | 0 | 0 | The number of Severely Errored Framing Seconds encountered by a t1 interface in the current 15 minute interval. A SEFS is a one … |
1.3.6.1.4.1.466.4.14.1.7 | ty3250T1CurrentUASs | 0 | 0 | The number of Unavailable Seconds encountered by a t1 interface in the current 15 minute in- terval. A UAS is a one second inter… |
1.3.6.1.4.1.466.4.14.1.8 | ty3250T1CurrentCSSs | 0 | 0 | The number of Controlled Slip Seconds encoun- tered by a t1 interface in the current 15 minute interval. A controlled slip is the… |
1.3.6.1.4.1.466.4.14.1.9 | ty3250T1CurrentBESs | 0 | 0 | The number of Bursty Errored Seconds (BESs) encountered by a DS1 interface in the current 15 minute interval. A BES is a one… |
1.3.6.1.4.1.466.4.14.1.10 | ty3250T1CurrentLCVs | 0 | 0 | The number of Line Code Violations (LCVs) en- countered by a DS1 interface in the current 15 minute interval. LCVs are non-B8ZS… |