The type of alarms that are generated on the node
Parsed from file tylink-netexec.mib.txt
Company: None
Module: NETEXEC-MIB
The type of alarms that are generated on the node
Parsed from file NETEXEC-MIB.mib
Module: NETEXEC-MIB
Vendor: Tylink
Module: NETEXEC-MIB
[Automatically extracted from oidview.com]
dsucsuAlarmType OBJECT-TYPE SYNTAX INTEGER { yellow-Alarm (1), sync-Alarm (2), red-Alarm (3), bpv-Alarm (4), confg-Activated (5), confg-Stored (6), pbx1-Yellow-Alarm (7), pbx1-Red-Alarm (8), pbx1-Los-Alarm (9), pbx3-Yellow-Alarm (10), pbx3-Red-Alarm (11), pbx3-Los-Alarm (12), ais-Alarm (13), node-communications-lost (14), sync-ais-Alarm (15), ts16-ais-Alarm (16), ts16-Los-Alarm (17), remote-Alarm (18), remote-ts16-Alarm (19), frame-Error-Alarm (20), crc4-Error-Alarm (21), port2-Yellow-Alarm (22), port2-Sync-Alarm (23), port2-Red-Alarm (24), port2-Bpv-Alarm (25), power-Supply-Alarm (26), fan-one-Failure (27), fan-two-Failure (28), yellow-Alarm-Clear (29), sync-Alarm-Clear (30), red-Alarm-Clear (31), bpv-Alarm-Clear (32), pbx1-Yellow-Alarm-Clear (33), pbx1-Red-Alarm-Clear (34), pbx1-Los-Alarm-Clear (35), pbx3-Yellow-Alarm-Clear (36), pbx3-Red-Alarm-Clear (37), pbx3-Los-Alarm-Clear (38), ais-Alarm-Clear (39), node-communications-restored (40), sync-ais-Alarm-Clear (41), ts16-ais-Alarm-Clear (42), ts16-Los-Alarm-Clear (43), remote-Alarm-Clear (44), remote-ts16-Alarm-Clear (45), frame-Error-Alarm-Clear (46), crc4-Error-Alarm-Clear (47), port2-Yellow-Alarm-Clear (48), port2-Sync-Alarm-Clear (49), port2-Red-Alarm-Clear (50), port2-Bpv-Alarm-Clear (51), power-Supply-Alarm-Clear (52), fan-one-Failure-Clear (53), fan-two-Failure-Clear (54) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of alarms that are generated on the node" ::= { dsucsu 25 }
dsucsuAlarmType OBJECT-TYPE SYNTAX INTEGER { yellow-Alarm (1), sync-Alarm (2), red-Alarm (3), bpv-Alarm (4), confg-Activated (5), confg-Stored (6), pbx1-Yellow-Alarm (7), pbx1-Red-Alarm (8), pbx1-Los-Alarm (9), pbx3-Yellow-Alarm (10), pbx3-Red-Alarm (11), pbx3-Los-Alarm (12), ais-Alarm (13), node-communications-lost (14), sync-ais-Alarm (15), ts16-ais-Alarm (16), ts16-Los-Alarm (17), remote-Alarm (18), remote-ts16-Alarm (19), frame-Error-Alarm (20), crc4-Error-Alarm (21), port2-Yellow-Alarm (22), port2-Sync-Alarm (23), port2-Red-Alarm (24), port2-Bpv-Alarm (25), power-Supply-Alarm (26), fan-one-Failure (27), fan-two-Failure (28), yellow-Alarm-Clear (29), sync-Alarm-Clear (30), red-Alarm-Clear (31), bpv-Alarm-Clear (32), pbx1-Yellow-Alarm-Clear (33), pbx1-Red-Alarm-Clear (34), pbx1-Los-Alarm-Clear (35), pbx3-Yellow-Alarm-Clear (36), pbx3-Red-Alarm-Clear (37), pbx3-Los-Alarm-Clear (38), ais-Alarm-Clear (39), node-communications-restored (40), sync-ais-Alarm-Clear (41), ts16-ais-Alarm-Clear (42), ts16-Los-Alarm-Clear (43), remote-Alarm-Clear (44), remote-ts16-Alarm-Clear (45), frame-Error-Alarm-Clear (46), crc4-Error-Alarm-Clear (47), port2-Yellow-Alarm-Clear (48), port2-Sync-Alarm-Clear (49), port2-Red-Alarm-Clear (50), port2-Bpv-Alarm-Clear (51), power-Supply-Alarm-Clear (52), fan-one-Failure-Clear (53), fan-two-Failure-Clear (54) } ACCESS read-only STATUS mandatory DESCRIPTION "The type of alarms that are generated on the node" ::= { dsucsu 25 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.466.6.1.25.0 | dsucsuAlarmType | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.466.6.1.0 | dsucsuTrap | 0 | 0 | None |
1.3.6.1.4.1.466.6.1.1 | dsucsuSysTable | 1 | 8 | A list of system level attributes describing the addressed node. |
1.3.6.1.4.1.466.6.1.2 | dsucsuCfgNetTable | 1 | 15 | Network Line Configuration |
1.3.6.1.4.1.466.6.1.4 | dsucsuCfgDteChanTable | 1 | 12 | DTE Channel Configuration |
1.3.6.1.4.1.466.6.1.5 | dsucsuCfgFrmChanTable | 1 | 14 | Framed Channel Configuration |
1.3.6.1.4.1.466.6.1.7 | dsucsuConfigSupTable | 1 | 5 | Inband Supervisory Channel Configuration |
1.3.6.1.4.1.466.6.1.8 | dsucsuCfgSupAuxTable | 1 | 5 | Auxillary Supervisory Channel Configuration |
1.3.6.1.4.1.466.6.1.9 | dsucsuActvConfTable | 1 | 4 | dsucsuActvConftable |
1.3.6.1.4.1.466.6.1.10 | dsucsuEventDesTable | 1 | 7 | Table of event destinations. Events or alarms detected by a node can be reported to up to two destinations. The operator can set… |
1.3.6.1.4.1.466.6.1.11 | dsucsuCfgMaintTable | 1 | 9 | Maint. Port Configuration |
1.3.6.1.4.1.466.6.1.12 | dsucsuCfgCommTable | 1 | 9 | Communication Port Configuration |
1.3.6.1.4.1.466.6.1.13 | dsucsuCfgBrdTable | 1 | 4 | Network timing for 3000N board. |
1.3.6.1.4.1.466.6.1.14 | dsucsuCfgDacsTable | 3 | 36 | None |
1.3.6.1.4.1.466.6.1.15 | dsucsuDiagNetTable | 1 | 15 | A list of Network Diagnostic attributes. Loopbacks, tests and their respective results can be initiated, cancelled and examined. |
1.3.6.1.4.1.466.6.1.16 | dsucsuDiagDteTable | 1 | 12 | A list of DTE channel diagnostics. |
1.3.6.1.4.1.466.6.1.17 | dsucsuDiagFrmTable | 1 | 16 | A list of framed channel diagnostics. |
1.3.6.1.4.1.466.6.1.18 | dsucsuDiagAuxTable | 1 | 9 | Auxillary Channel Diagnostics |
1.3.6.1.4.1.466.6.1.19 | dsucsuDiagPortTable | 1 | 6 | Port Specific Display only Diagnostics |
1.3.6.1.4.1.466.6.1.20 | dsucsuIntervalTable | 1 | 9 | The table contains various ESF stats collected over the last 96 15-minute intervals (24 hours total time). |
1.3.6.1.4.1.466.6.1.22 | dsucsuCurrentTable | 1 | 9 | The table contains various ESF stats collected over the current 15-minute interval. |
1.3.6.1.4.1.466.6.1.24 | dsucsuTotalTable | 1 | 9 | The table contains the cummulative sum of various ESF stats collected over the last 24 hour period. |
1.3.6.1.4.1.466.6.1.26 | dsucsuAlarmSlot | 1 | 1 | The PC port to which the TyView node is attached. |
1.3.6.1.4.1.466.6.1.27 | dsucsuAlarmNode | 1 | 1 | The node ID: unique per port ID. |
1.3.6.1.4.1.466.6.1.28 | dsucsuAlarmName | 1 | 1 | The name of the node which triggered the alarm. |