Reference record for OID 1.3.6.1.4.1.476.1.42.3.5.1.18



parent
1.3.6.1.4.1.476.1.42.3.5.1 (lgpPwrBattery)
node code
18
node name
lgpPwrBatteryTimeRemaining
dot oid
1.3.6.1.4.1.476.1.42.3.5.1.18
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) emerson(476) liebertCorp(1) liebertGlobalProducts(42) lgpFoundation(3) lgpPower(5) lgpPwrBattery(1) lgpPwrBatteryTimeRemaining(18)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • /iso/identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • /iso/org/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • /iso/org/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • /iso/iso-identified-organization/dod/internet/private/enterprise/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • /iso/iso-identified-organization/dod/internet/private/enterprises/emerson/liebertCorp/liebertGlobalProducts/lgpFoundation/lgpPower/lgpPwrBattery/lgpPwrBatteryTimeRemaining
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/476/1/42/3/5/1/18

    Description by mibdepot

    An estimate of the time to battery charge depletion under the present
    load conditions if the utility power is off and remains off, or if it
    were to be lost and remain off.

    NOTE: A UPS is expected to provide a battery time remaining value
    when not operating on battery. However, if the system is not capable of
    providing this information, then this point will return 65535 to
    indicate that the value is unavailable.

    Parsed from file LIEBERT_GP_POWER.MIB.txt
    Company: None
    Module: LIEBERT-GP-POWER-MIB

    Description by circitor

    An estimate of the time to battery charge depletion under the present
    load conditions if the utility power is off and remains off, or if it
    were to be lost and remain off.

    Parsed from file LIEBERT-GP-POWER-MIB.mib
    Module: LIEBERT-GP-POWER-MIB

    Information by oid_info

    Vendor: Emerson Computer PowerRoger Draper
    Module: LIEBERT-GP-POWER-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    lgpPwrBatteryTimeRemaining OBJECT-TYPE SYNTAX Integer32 UNITS "minutes" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. NOTE: A UPS is expected to provide a battery time remaining value when not operating on battery. However, if the system is not capable of providing this information, then this point will return 65535 to indicate that the value is unavailable." ::= { lgpPwrBattery 18 }

    Information by circitor

    lgpPwrBatteryTimeRemaining OBJECT-TYPE SYNTAX Integer32 UNITS "minutes" MAX-ACCESS read-only STATUS current DESCRIPTION "An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off." ::= { lgpPwrBattery 18 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.476)

    [email protected]

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.476.1.42.3.5.1.18.0 lgpPwrBatteryTimeRemaining 0 0 None

    Brothers (25)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.476.1.42.3.5.1.1 lgpPwrNumberInstalledBatteryModules 1 1 The number of battery modules installed in the device.
    1.3.6.1.4.1.476.1.42.3.5.1.2 lgpPwrNumberFailedBatteryModules 1 1 The number of battery modules in the device that have failed.
    1.3.6.1.4.1.476.1.42.3.5.1.3 lgpPwrNumberRedundantBatteryModules 1 1 The number of redundant battery modules in the device.
    1.3.6.1.4.1.476.1.42.3.5.1.4 lgpPwrNumberActiveBatteryModules 1 1 The number of active battery modules in the device.
    1.3.6.1.4.1.476.1.42.3.5.1.5 lgpPwrConfigLowBatteryWarningTime 1 1 The value of the device's estimated minutes of remaining battery
    at which a lgpEventLowBatteryWarning notification will be sent.
    1.3.6.1.4.1.476.1.42.3.5.1.6 lgpPwrNumberBatteryModuleWarnings 1 1 The number of battery modules in the device that have a warning.
    1.3.6.1.4.1.476.1.42.3.5.1.7 lgpPwrBatteryCount 1 1 The number of batteries installed.
    1.3.6.1.4.1.476.1.42.3.5.1.8 lgpPwrBatteryTestResult 1 1 The outcome of the previous battery test.
    1.3.6.1.4.1.476.1.42.3.5.1.9 lgpPwrNominalBatteryCapacity 1 1 The nominal battery capacity of the system (in minutes) at full load.
    1.3.6.1.4.1.476.1.42.3.5.1.10 lgpPwrBatteryFloatVoltage 1 1 The battery float voltage of the system.
    1.3.6.1.4.1.476.1.42.3.5.1.11 lgpPwrBatteryEndOfDischargeVoltage 1 1 The battery voltage threshold at which the batteries are consided
    completely discharged.
    1.3.6.1.4.1.476.1.42.3.5.1.12 lgpPwrAutomaticBatteryTestInterval 1 1 The automatic battery test interval.
    1.3.6.1.4.1.476.1.42.3.5.1.13 lgpPwrAutomaticBatteryTestCountdown 1 1 The time remaining before the next battery test.
    1.3.6.1.4.1.476.1.42.3.5.1.14 lgpPwrBatteryChargeStatus 1 1 The present state of the system's battery charge.
    A value of 'charging' indicates the batteries are currently charging.
    A value o…
    1.3.6.1.4.1.476.1.42.3.5.1.15 lgpPwrBatteryLifeEnhancer 1 1 The state of the battery life enhancer. When 'on', it will
    preserve battery life.
    1.3.6.1.4.1.476.1.42.3.5.1.16 lgpPwrBatteryCharger 1 1 The state of the battery charger.
    1.3.6.1.4.1.476.1.42.3.5.1.17 lgpPwrBatteryChargeMode 1 1 The mode of the battery charger: 'float' charging or 'equalize'
    charging.
    1.3.6.1.4.1.476.1.42.3.5.1.19 lgpPwrBatteryCapacity 1 1 The present percentage of battery capacity.
    1.3.6.1.4.1.476.1.42.3.5.1.20 lgpPwrBatteryCabinet 5 10 This sub-tree contains items related to battery cabinets.
    1.3.6.1.4.1.476.1.42.3.5.1.21 lgpPwrBatteryAmpHoursConsumed 1 1 The cumulative battery Amp-hours withdrawn over the life of the
    battery. This value persists across reboots. Typically, this val…
    1.3.6.1.4.1.476.1.42.3.5.1.22 lgpPwrBatteryAmpHoursDischargeConsumed 1 1 The battery Amp-hours withdrawn during the current/latest
    discharge. This value does not persist across reboots.
    1.3.6.1.4.1.476.1.42.3.5.1.23 lgpPwrBatteryLastDischargeTime 1 1 The date and time of the last battery discharge. Typically this is the
    time when the discharge starts. This value persists acros…
    1.3.6.1.4.1.476.1.42.3.5.1.24 lgpPwrBatteryLastCommissionTime 1 1 The date and time when the battery system was put into service.
    This information persists across system reboot events. It is the…
    1.3.6.1.4.1.476.1.42.3.5.1.25 lgpPwrBatteryPresentDischargeTime 1 1 The total time spent on battery during the current or last discharge.

    NOTE: While not discharging, some systems may display zero…
    1.3.6.1.4.1.476.1.42.3.5.1.26 lgpPwrBatteryCapacityStatus 1 1 The indication of the capacity remaining in the UPS
    system's batteries.

    NOTE: In a single-module system, this point is intended t…