The present description of the Power Factor for the power source
indicated by 'lgpPwrMeasurementPointId' in the corresponding row
in the lgpPwrMeasurementPointTable. If Leading, the load is said
to be capacitive and the phase of the current leads the voltage.
If Lagging, the load is said to be inductive and the phase of the
current lags the voltage.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
The present description of the Power Factor for the power source
indicated by 'lgpPwrMeasurementPointId' in the corresponding row
in the lgpPwrMeasurementPointTable. If Leading, the load is said
to be capacitive and the phase of the current leads the voltage.
If Lagging, the load is said to be inductive and the phase of the
current lags the voltage.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrMeasurementPointPowerFactorTag OBJECT-TYPE SYNTAX INTEGER { leading(1), lagging(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "The present description of the Power Factor for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasurementPointTable. If Leading, the load is said to be capacitive and the phase of the current leads the voltage. If Lagging, the load is said to be inductive and the phase of the current lags the voltage." ::= { lgpPwrMeasurementPointEntry 19 }
lgpPwrMeasurementPointPowerFactorTag OBJECT-TYPE SYNTAX INTEGER {leading(1), lagging(2)} MAX-ACCESS read-only STATUS current DESCRIPTION "The present description of the Power Factor for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasurementPointTable. If Leading, the load is said to be capacitive and the phase of the current leads the voltage. If Lagging, the load is said to be inductive and the phase of the current lags the voltage." ::= { lgpPwrMeasurementPointEntry 19 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.2.2.1.1 | lgpPwrMeasurementPointIndex | 0 | 0 | This is the index that indicates the row of the 'lgpPwrMeasurementPointTable' for a power measurement point. |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.2 | lgpPwrMeasurementPointId | 0 | 0 | An OID representing a well known measurement point. These object identifiers indicate a point or location of power measurement in… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.3 | lgpPwrMeasurementPointNumLines | 0 | 0 | The number of lines on the indicated power measurement point. (i.e. the number of phases on the power source being measured.) |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.4 | lgpPwrMeasurementPointNomVolts | 0 | 0 | The magnitude of the nominal voltage on the power source being measured. |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.5 | lgpPwrMeasurementPointNomFrequency | 0 | 0 | The nominal or configured/expected frequency for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding ro… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.6 | lgpPwrMeasurementPointFrequency | 0 | 0 | The present (actual) frequency for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPw… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.7 | lgpPwrMeasurementPointApparentPower | 0 | 0 | The present apparent AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwr… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.8 | lgpPwrMeasurementPointTruePower | 0 | 0 | The present AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasureme… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.9 | lgpPwrMeasurementPointPowerFactor | 0 | 0 | The present Power Factor for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasu… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.10 | lgpPwrMeasurementPointWattHours | 0 | 0 | The present number of Watt Hours for the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgp… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.11 | lgpPwrMeasurementPointVAPercent | 0 | 0 | The percentage of the rated apparent AC power of the power source indicated by 'lgpPwrMeasurementPointId' in the corresponding ro… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.12 | lgpPwrMeasurementPointNeutralCurrent | 0 | 0 | The present neutral current of the power point indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeas… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.13 | lgpPwrMeasurementPointGroundCurrent | 0 | 0 | The present ground current of the power point indicated by 'lgpPwrMeasurementPointId' in the corresponding row in the lgpPwrMeasu… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.14 | lgpPwrMeasurementPointNomCurrent | 0 | 0 | The nominal or configured/expected current of the power point indicated by 'lgpPwrMeasurementPointId' in the corresponding row in… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.15 | lgpPwrMeasurementPointNomPowerFactor | 0 | 0 | The nominal or configured/expected power factor of the power point indicated by 'lgpPwrMeasurementPointId' in the corresponding … |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.16 | lgpPwrMeasurementPointNomVA | 0 | 0 | The nominal or configured/expected apparent AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the corresp… |
1.3.6.1.4.1.476.1.42.3.5.2.2.1.17 | lgpPwrMeasurementPointNomW | 0 | 0 | The nominal or configured/expected true AC power for the power source indicated by 'lgpPwrMeasurementPointId' in the correspondi… |