This sub-tree registers well known Liebert Power Control
Points. The object identifier names usually imply locations
where control of a device is available
'load circuits'.
Parsed from file LIEBERT_GP_POWER.MIB.txt
Company: None
Module: LIEBERT-GP-POWER-MIB
This sub-tree registers well known Liebert Power Control
Points. The object identifier names usually imply locations
where control of a device is available
'load circuits'.
Parsed from file LIEBERT-GP-POWER-MIB.mib
Module: LIEBERT-GP-POWER-MIB
Vendor: Emerson Computer PowerRoger Draper
Module: LIEBERT-GP-POWER-MIB
[Automatically extracted from oidview.com]
lgpPwrWellKnownControlPoints OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers well known Liebert Power Control Points. The object identifier names usually imply locations where control of a device is available 'load circuits'." REFERENCE "These well known control identifiers are referenced in the 'lgpPwrLoadCircuitId' column in the 'lgpPwrLoadCircuitTable'." ::= { lgpPwrControl 1 }
lgpPwrWellKnownControlPoints OBJECT-IDENTITY STATUS current DESCRIPTION "This sub-tree registers well known Liebert Power Control Points. The object identifier names usually imply locations where control of a device is available 'load circuits'." REFERENCE "These well known control identifiers are referenced in the 'lgpPwrLoadCircuitId' column in the 'lgpPwrLoadCircuitTable'." ::= { lgpPwrControl 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.6.1.1 | lgpPwrLoadCircuit | 0 | 0 | The managed device's controllable load circuit. Many power systems contain more than one load circuit. This identifier represents… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.476.1.42.3.5.6.2 | lgpPwrLoadCircuitTable | 1 | 5 | A list of load circuits that can be controlled(opened or closed). The NMS cannot create or delete rows from the table. The rows a… |
1.3.6.1.4.1.476.1.42.3.5.6.3 | lgpPwrAlarmSilence | 1 | 1 | Audible Alarm Silence Command. This command turns off the device's audible alarm. It will not affect the status of the alarm(s… |
1.3.6.1.4.1.476.1.42.3.5.6.4 | lgpPwrBatteryTest | 1 | 1 | Battery Test Command. This command will initiate a battery test if one is not already in progress, or abort the current test if… |
1.3.6.1.4.1.476.1.42.3.5.6.5 | lgpPwrUpsAbortCommand | 1 | 1 | UPS Abort command. This command will abort the pending command on the device. There is no guarantee a client using the abort c… |
1.3.6.1.4.1.476.1.42.3.5.6.6 | lgpPwrTransferToBypass | 1 | 1 | Transfer to Bypass Command. This command will initiate a transfer of the load to the bypass of the system. This command should … |
1.3.6.1.4.1.476.1.42.3.5.6.7 | lgpPwrTransferToInverter | 1 | 1 | Transfer to Inverter Command. This command will initiate a transfer of the load to the inverter of the system. This command sho… |
1.3.6.1.4.1.476.1.42.3.5.6.8 | lgpPwrOutputOnDelay | 1 | 1 | Output On Delay Command. This command will turn on the output of the device after a user specified delay. The number of second… |
1.3.6.1.4.1.476.1.42.3.5.6.9 | lgpPwrOutputOffDelayWithRestart | 1 | 1 | Output Off Delay with Restart Command. This command will turn off the output of the device after a user specified delay. The n… |
1.3.6.1.4.1.476.1.42.3.5.6.10 | lgpPwrOutputOffDelayWithoutRestart | 1 | 1 | Output Off Delay without Restart Command. This command will turn off the output of the device after a specified delay. The num… |