Use this menu to specify what type of copy is being made so
the printer can optimize for this type output.
Choices
Automatic Gray, Custom Gray, Binary B/W, Halftone B/W
Notes
Automatic Gray-Sets color depth to 8-bit gray and scan
resolution to 200 dpi. Use this option when copying
documents that are black and white or shades of gray. Best
quality output for images.
Custom Gray-Allows you to adjust grayscale values.
Binary B/W-Allows you to adjust binary thresholds. Good for
text.
Halftone B/W-Allows you to adjust the brightness of halftone
images.
Note
In order to change the default grayscale value, you must
choose the Custom Gray option in this menu.
Parsed from file QMS-MIB.mib
Module: QMS-MIB
Vendor: QMS, Inc.
Module: QMS-MIB
[Automatically extracted from oidview.com]
qmsSCCopyMode OBJECT-TYPE SYNTAX INTEGER { automaticColor(8), customColor(9), binaryColor(10), halftoneColor(11), automaticGray(4), customGray(5), binaryBandW(6), halftoneBandW(7) } ACCESS read-write STATUS mandatory DESCRIPTION "Use this menu to specify what type of copy is being made so the printer can optimize for this type output. Choices Automatic Gray, Custom Gray, Binary B/W, Halftone B/W Notes Automatic Gray-Sets color depth to 8-bit gray and scan resolution to 200 dpi. Use this option when copying documents that are black and white or shades of gray. Best quality output for images. Custom Gray-Allows you to adjust grayscale values. Binary B/W-Allows you to adjust binary thresholds. Good for text. Halftone B/W-Allows you to adjust the brightness of halftone images. Note In order to change the default grayscale value, you must choose the Custom Gray option in this menu." ::= { qmsScanner 24 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.480.1.402.3 | qmsSCColorAdjust | 0 | 0 | Use this option to adjust brightness in copies. It allows you to adjust the brightness of halftone images. This setting is enable… |
1.3.6.1.4.1.480.1.402.4 | qmsSCScanResolution | 0 | 0 | Use this menu to specify what resolution the scanner should use. Choices 100, 150, 200, or 300 dpi Choose a scan resolution that is… |
1.3.6.1.4.1.480.1.402.8 | qmsSCSizeHorizontal | 0 | 0 | Use this to scan only part of the scannable area in order to copy only part of an image or to reduce copying time for images smal… |
1.3.6.1.4.1.480.1.402.12 | qmsSCSizeVertical | 0 | 0 | Use this to scan only part of the scannable area in order to copy only part of an image or to reduce copying time for images smal… |
1.3.6.1.4.1.480.1.402.16 | qmsSCOffsetHorizontal | 0 | 0 | Use this menu to specify where the copy is to print on the selected media (in 0.01'' increments). Choices 0-850 Default 0 Notes This o… |
1.3.6.1.4.1.480.1.402.20 | qmsSCOffsetVertical | 0 | 0 | Use this menu to specify where the copy is to print on the selected media (in 0.01'' increments). Choices 0-1100 Default 0 Notes This … |
1.3.6.1.4.1.480.1.402.26 | qmsSCRedGammaFunction | 0 | 0 | None |
1.3.6.1.4.1.480.1.402.27 | qmsSCGreenGammaFunction | 0 | 0 | None |
1.3.6.1.4.1.480.1.402.28 | qmsSCBlueGammaFunction | 0 | 0 | None |
1.3.6.1.4.1.480.1.402.29 | qmsSCGrayGammaFunction | 0 | 0 | Need description |
1.3.6.1.4.1.480.1.402.31 | qmsSCBinaryAdjustment | 0 | 0 | None |
1.3.6.1.4.1.480.1.402.35 | qmsSCTrans | 0 | 0 | Use this option to specify how you want the Transparency Adapter (an optional accessory) to work. Choices Enabled: Specifies trans… |
1.3.6.1.4.1.480.1.402.36 | qmsSCContrast | 0 | 0 | Use this option to adjust contrast in copies. Choices 15 contrast settings (1-15); each makes an incremental contrast change of ab… |