High temperature threshold limit of a CMTS device in degrees
Celsius, above which an event occurs to signal that the
threshold has been exceeded. The device temperature is read
once per minute and compared to this threshold value. A trap
is sent out if the event's priority indicates that a trap
is to be sent (refer to the docsDevEvControlTable object in
DOCS-CABLE-DEVICE-MIB). The priority of this event is critical(3).
Parsed from file LANCITY-MCNS-MIB.mib.txt
Company: None
Module: LANCITY-MCNS-MIB
lcCmtsHightempThreshold
View at oid-info.com
High temperature threshold limit of a CMTS device in degrees
Celsius, above which an event occurs to signal that the
threshold has been exceeded. The device temperature is read
once per minute and compared to this threshold value. A trap
is sent out if the event's priority indicates that a trap
is to be sent (refer to the docsDevEvControlTable object in
DOCS-CABLE-DEVICE-MIB). The priority of this event is critical(3).
Parsed from file LANCITY-MCNS-MIB.mib
Module: LANCITY-MCNS-MIB
lcCmtsHighTempThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature threshold limit of a CMTS device in degrees Celsius, above which an event occurs to signal that the threshold has been exceeded. The device temperature is read once per minute and compared to this threshold value. A trap is sent out if the event's priority indicates that a trap is to be sent (refer to the docsDevEvControlTable object in DOCS-CABLE-DEVICE-MIB). The priority of this event is critical(3)." DEFVAL { 100 } ::= { lccmtsif 3 }
Vendor: LANcity Corporation
Module: LANCITY-MCNS-MIB
[Automatically extracted from oidview.com]
lcCmtsHighTempThreshold OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-write STATUS current DESCRIPTION "High temperature threshold limit of a CMTS device in degrees Celsius, above which an event occurs to signal that the threshold has been exceeded. The device temperature is read once per minute and compared to this threshold value. A trap is sent out if the event's priority indicates that a trap is to be sent (refer to the docsDevEvControlTable object in DOCS-CABLE-DEVICE-MIB). The priority of this event is critical(3)." DEFVAL { 100 } ::= { lccmtsif 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.482.60.2.3.0 | lcCmtsHighTempThreshold | 0 | 0 | lcCmtsHightempThreshold |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.482.60.2.1 | lcCmtsUpstreamTable | 1 | 14 | Defines properties of upstream channels, from the CMTS. |
1.3.6.1.4.1.482.60.2.2 | lcCmtsCurrentTemp | 1 | 1 | Current temperature of a CMTS device in degrees Celsius. |
1.3.6.1.4.1.482.60.2.4 | lccmtsUpstreamIngressAvoidance | 9 | 52 | None |
1.3.6.1.4.1.482.60.2.5 | lcCmtsMultiUsConfigTable | 1 | 3 | Defines carrier paths (Physical Connectivity) and channel groups for each upstream. |
1.3.6.1.4.1.482.60.2.6 | lcCmtsFrontFanOn | 1 | 1 | Current on/off state of the CMTS fan closest to the front of the chassis. If the fan is on, true is returned. If the fan is off,… |
1.3.6.1.4.1.482.60.2.7 | lcCmtsMiddleFanOn | 1 | 1 | Current on/off state of the CMTS fan closest to the middle of the chassis. If the fan is on, true is returned. If the fan is off… |
1.3.6.1.4.1.482.60.2.8 | lcCmtsBackFanOn | 1 | 1 | Current on/off state of the CMTS fan closest to the back of the chassis. If the fan is on, true is returned. If the fan is off, … |
1.3.6.1.4.1.482.60.2.9 | lccmtsifconfig | 2 | 4 | None |
1.3.6.1.4.1.482.60.2.10 | lcEvSyslog2 | 1 | 1 | The IP address of a 2nd Syslog server. If 0.0.0.0, syslog transmission is inhibited. |
1.3.6.1.4.1.482.60.2.11 | lcEvSyslog3 | 1 | 1 | The IP address of a 3rd Syslog server. If 0.0.0.0, syslog transmission is inhibited. |
1.3.6.1.4.1.482.60.2.16 | lcCpeMacToCmMacTable | 1 | 3 | This is a table to provide a mechanism for finding the MAC address of the CM to which a CPE device is connected. The table is ind… |
1.3.6.1.4.1.482.60.2.19 | lcCmCountsTable | 1 | 4 | This is a table to provide the number of active and registered modems on each upstream and for the entire system. Active modems … |