This table contains entries for Frame Relay circuits configured on
Frame Relay Subinterfaces present in the system.
An implementation may constrain the number of circuits permitted
to be configured per Frame Relay Subinterface; in particular,
an implementation may restrict each Frame Relay Subinterface to
have a single circuit.
Attributes in this entry can only be configured at entry creation,
and remain fixed for the lifetime of the entry.
Parsed from file usDataFr.mi2.txt
Company: None
Module: Unisphere-Data-FRAME-RELAY-MIB
This table contains entries for Frame Relay circuits configured on
Frame Relay Subinterfaces present in the system.
An implementation may constrain the number of circuits permitted to be
configured per Frame Relay Subinterface; in particular, an
implementation may restrict each Frame Relay Subinterface to have a
single circuit.
Attributes in this entry can only be configured at entry creation, and
remain fixed for the lifetime of the entry.
Parsed from file Juniper-FRAME-RELAY-MIB.mib
Module: Juniper-FRAME-RELAY-MIB
Vendor: Juniper Networks/Unisphere
Module: Juniper-FRAME-RELAY-MIB
[Automatically extracted from oidview.com]
usdFrSubIfCktTable OBJECT-TYPE SYNTAX SEQUENCE OF UsdFrSubIfCktEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for Frame Relay circuits configured on Frame Relay Subinterfaces present in the system. An implementation may constrain the number of circuits permitted to be configured per Frame Relay Subinterface; in particular, an implementation may restrict each Frame Relay Subinterface to have a single circuit. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry. " ::= { usdFrSubIfLayer 3 }
juniFrSubIfCktTable OBJECT-TYPE SYNTAX SEQUENCE OF JuniFrSubIfCktEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains entries for Frame Relay circuits configured on Frame Relay Subinterfaces present in the system. An implementation may constrain the number of circuits permitted to be configured per Frame Relay Subinterface; in particular, an implementation may restrict each Frame Relay Subinterface to have a single circuit. Attributes in this entry can only be configured at entry creation, and remain fixed for the lifetime of the entry." ::= { juniFrSubIfLayer 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.10.1.2.3.1 | juniFrSubIfCktEntry, usdFrSubIfCktEntry | 2 | 2 | Each entry describes the characteristics of a Frame Relay Subinterface circuit. |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.10.1.2.1 | juniFrSubIfNextIfIndex, usdFrSubIfNextIfIndex | 1 | 1 | Coordinate ifIndex value allocation for entries in juniFrSubIfTable. A GET of this object returns the next available ifIndex val… |
1.3.6.1.4.1.4874.2.2.10.1.2.2 | juniFrSubIfTable, usdFrSubIfTable | 1 | 5 | juniFrSubIftable |