A table of system module and sub-module information. In this table, a
module refers to a physical module (board) or a sub-module.
A physical board may contain a single module or multiple sub-modules.
For example, an ERX line card is a single module and appears as single
entry in this table. An I/O adapter is a module that doesn't provide
any operaitonal state information and it also appears as a single entry
in this table. A second generation E-series SRP/SFS hardware module
contains two sub-modules, each with its own operational state
information: a System Resource Processor (SRP) sub-module and a Switch
Fabric Slice (SFS) sub-module, which appear as two separate entries in
this table, one for each sub-module.
Parsed from file juniSystem.mi2.txt
Company: None
Module: Juniper-System-MIB
A table of system module and sub-module information. In this table, a
module refers to a physical module (board) or a sub-module.
A physical board may contain a single module or multiple sub-modules.
For example, an ERX line card is a single module and appears as single
entry in this table. An I/O adapter is a module that doesn't provide
any operaitonal state information and it also appears as a single entry
in this table. A second generation E-series SRP/SFS hardware module
contains two sub-modules, each with its own operational state
information: a System Resource Processor (SRP) sub-module and a Switch
Fabric Slice (SFS) sub-module, which appear as two separate entries in
this table, one for each sub-module.
Parsed from file Juniper-System-MIB.mib
Module: Juniper-System-MIB
Vendor: Juniper Networks/Unisphere
Module: Juniper-System-MIB
[Automatically extracted from oidview.com]
juniSystemModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF JuniSystemModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of system module and sub-module information. In this table, a module refers to a physical module (board) or a sub-module. A physical board may contain a single module or multiple sub-modules. For example, an ERX line card is a single module and appears as single entry in this table. An I/O adapter is a module that doesn't provide any operaitonal state information and it also appears as a single entry in this table. A second generation E-series SRP/SFS hardware module contains two sub-modules, each with its own operational state information: a System Resource Processor (SRP) sub-module and a Switch Fabric Slice (SFS) sub-module, which appear as two separate entries in this table, one for each sub-module." ::= { juniSystemModule 4 }
juniSystemModuleTable OBJECT-TYPE SYNTAX SEQUENCE OF JuniSystemModuleEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table of system module and sub-module information. In this table, a module refers to a physical module (board) or a sub-module. A physical board may contain a single module or multiple sub-modules. For example, an ERX line card is a single module and appears as single entry in this table. An I/O adapter is a module that doesn't provide any operaitonal state information and it also appears as a single entry in this table. A second generation E-series SRP/SFS hardware module contains two sub-modules, each with its own operational state information: a System Resource Processor (SRP) sub-module and a Switch Fabric Slice (SFS) sub-module, which appear as two separate entries in this table, one for each sub-module." ::= { juniSystemModule 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.2.1.3.4.1 | juniSystemModuleEntry | 15 | 15 | A table entry that provides information about a specific system module or sub-module in a particular module location. There are… |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.4874.2.2.2.1.3.1 | juniSystemMaxSlotNumber | 1 | 1 | The highest number assigned to a slot in the system. In a particular hardware model, module slots have fixed numbers assigned t… |
1.3.6.1.4.1.4874.2.2.2.1.3.2 | juniSystemMaxModulesPerSlot | 1 | 1 | The maximum number of modules and sub-modules (different levels) that can be associated with a slot number in the system. This … |
1.3.6.1.4.1.4874.2.2.2.1.3.3 | juniSystemSlotTable | 1 | 5 | A table of system module slot physical container configuration information. |
1.3.6.1.4.1.4874.2.2.2.1.3.5 | juniSystemModuleSoftwareTable | 1 | 11 | A table of system module software information. This includes the version of the software running on the particular module, the … |
1.3.6.1.4.1.4874.2.2.2.1.3.6 | juniSystemModuleRedundancyTable | 1 | 7 | A table of system module redundancy information. Note that modules that do not support redundancy information will not appear i… |