Reference record for OID 1.3.6.1.4.1.4874.2.2.56.1.1.1



parent
1.3.6.1.4.1.4874.2.2.56.1.1 (juniSysClockTime, usdSysClockTime)
node code
1
node names
  • juniSysClockDateAndTime
  • usdSysClockDateAndTime
  • dot oid
    1.3.6.1.4.1.4874.2.2.56.1.1.1
    type
    OBJECT-TYPE
    asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) juniperUni(4874) juniperUniMibs(2) juniMibs(2) juniSysClockMIB(56) juniSysClockObjects(1) juniSysClockTime(1) juniSysClockDateAndTime(1)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) juniperUni(4874) juniperUniMibs(2) juniMibs(2) juniSysClockMIB(56) juniSysClockObjects(1) juniSysClockTime(1) usdSysClockDateAndTime(1)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) unisphere(4874) usMibs(2) usDataMibs(2) usdSysClockMIB(56) usdSysClockObjects(1) usdSysClockTime(1) juniSysClockDateAndTime(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) unisphere(4874) usMibs(2) usDataMibs(2) usdSysClockMIB(56) usdSysClockObjects(1) usdSysClockTime(1) usdSysClockDateAndTime(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) juniperUni(4874) juniperUniMibs(2) juniMibs(2) juniSysClockMIB(56) juniSysClockObjects(1) juniSysClockTime(1) juniSysClockDateAndTime(1)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) juniperUni(4874) juniperUniMibs(2) juniMibs(2) juniSysClockMIB(56) juniSysClockObjects(1) juniSysClockTime(1) usdSysClockDateAndTime(1)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisphere(4874) usMibs(2) usDataMibs(2) usdSysClockMIB(56) usdSysClockObjects(1) usdSysClockTime(1) juniSysClockDateAndTime(1)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) unisphere(4874) usMibs(2) usDataMibs(2) usdSysClockMIB(56) usdSysClockObjects(1) usdSysClockTime(1) usdSysClockDateAndTime(1)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/juniperUni/juniperUniMibs/juniMibs/juniSysClockMIB/juniSysClockObjects/juniSysClockTime/juniSysClockDateAndTime
  • /iso/identified-organization/dod/internet/private/enterprise/juniperUni/juniperUniMibs/juniMibs/juniSysClockMIB/juniSysClockObjects/juniSysClockTime/usdSysClockDateAndTime
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/unisphere/usMibs/usDataMibs/usdSysClockMIB/usdSysClockObjects/usdSysClockTime/juniSysClockDateAndTime
  • /iso/org/dod/internet/private/enterprise/unisphere/usMibs/usDataMibs/usdSysClockMIB/usdSysClockObjects/usdSysClockTime/usdSysClockDateAndTime
  • /iso/org/dod/internet/private/enterprises/juniperUni/juniperUniMibs/juniMibs/juniSysClockMIB/juniSysClockObjects/juniSysClockTime/juniSysClockDateAndTime
  • /iso/org/dod/internet/private/enterprises/juniperUni/juniperUniMibs/juniMibs/juniSysClockMIB/juniSysClockObjects/juniSysClockTime/usdSysClockDateAndTime
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/unisphere/usMibs/usDataMibs/usdSysClockMIB/usdSysClockObjects/usdSysClockTime/juniSysClockDateAndTime
  • /iso/iso-identified-organization/dod/internet/private/enterprises/unisphere/usMibs/usDataMibs/usdSysClockMIB/usdSysClockObjects/usdSysClockTime/usdSysClockDateAndTime
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/4874/2/2/56/1/1/1

    Description by mibdepot

    This object is used to manage the system clock time, date and timezone.
    If the Network Time Protocol (NTP) is enabled, attempts to set this
    object will result in an inconsistantValue error. For sets, the
    implementation may check the value of the year and if it is outside of a
    'reasonable' range (e.g., 1999..2035) it may return an inconsistantValue
    error. Only system clock time and date will be set if the timezone
    offset is not set along with the timezone name.

    Parsed from file juniSystemClock.mi2.txt
    Company: None
    Module: Juniper-System-Clock-MIB

    Description by circitor

    This object is used to manage the system clock time, date and timezone.
    If the Network Time Protocol (NTP) is enabled, attempts to set this
    object will result in an inconsistantValue error. For sets, the
    implementation may check the value of the year and if it is outside of a
    'reasonable' range (e.g., 1999..2035) it may return an inconsistantValue
    error. Only system clock time and date will be set if the timezone
    offset is not set along with the timezone name.

    Parsed from file Unisphere-Data-System-Clock-MIB.mib
    Module: Unisphere-Data-System-Clock-MIB

    Information by oid_info

    Vendor: Juniper Networks/Unisphere
    Module: Juniper-System-Clock-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    juniSysClockDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to manage the system clock time, date and timezone. If the Network Time Protocol (NTP) is enabled, attempts to set this object will result in an inconsistantValue error. For sets, the implementation may check the value of the year and if it is outside of a 'reasonable' range (e.g., 1999..2035) it may return an inconsistantValue error. Only system clock time and date will be set if the timezone offset is not set along with the timezone name." ::= { juniSysClockTime 1 }

    Information by circitor

    usdSysClockDateAndTime OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-write STATUS current DESCRIPTION "This object is used to manage the system clock time, date and timezone. If the Network Time Protocol (NTP) is enabled, attempts to set this object will result in an inconsistantValue error. For sets, the implementation may check the value of the year and if it is outside of a 'reasonable' range (e.g., 1999..2035) it may return an inconsistantValue error. Only system clock time and date will be set if the timezone offset is not set along with the timezone name." ::= { usdSysClockTime 1 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.4874)

    Scano John

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.4874.2.2.56.1.1.1.0 juniSysClockDateAndTime 0 0 None

    Brothers (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.4874.2.2.56.1.1.2 juniSysClockTimeZoneName, usdSysClockTimeZoneName 1 1 Name of the timezone. Timezone name take effects only with its offset
    set along with it.