The mastership priority of this agent. Ten is the
highest and one is the lowest. Never means will not
be able become master. Some agents do not have the
capability to become master (the 5102B-EE, e.g.)
and setting those agents to a value other than never(11)
will generate an invalid value error. Priority is
only used when an election occurs. Mastership is not
pre-emptive; use the reset mastership command.
Parsed from file chipcom-emm.mib.txt
Company: None
Module: ChpCom-EMM
The mastership priority of this agent. Ten is the
highest and one is the lowest. Never means will not
be able become master. Some agents do not have the
capability to become master (the etherent to ethernet bridge,
e.g.) and setting those agents to a value other than
never(11) will generate an invalid value error. Priority is
only used when an election occurs. Mastership is not
pre-emptive; use the reset mastership command
(olAgentsMasterReset).
Parsed from file CHIPCOMMIB.mib
Module: CHIPCOMMIB
Vendor: Chippcom
Module: CHIPCOMMIB
[Automatically extracted from oidview.com]
olAgentsMasterPriority OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10), never(11) } ACCESS read-write STATUS mandatory DESCRIPTION "The mastership priority of this agent. Ten is the highest and one is the lowest. Never means will not be able become master. Some agents do not have the capability to become master (the 5102B-EE, e.g.) and setting those agents to a value other than never(11) will generate an invalid value error. Priority is only used when an election occurs. Mastership is not pre-emptive; use the reset mastership command." ::= { olAgentsEntry 5 }
olAgentsMasterPriority OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8), nine(9), ten(10), never(11) } ACCESS read-write STATUS mandatory DESCRIPTION "The mastership priority of this agent. Ten is the highest and one is the lowest. Never means will not be able become master. Some agents do not have the capability to become master (the etherent to ethernet bridge, e.g.) and setting those agents to a value other than never(11) will generate an invalid value error. Priority is only used when an election occurs. Mastership is not pre-emptive; use the reset mastership command (olAgentsMasterReset)." ::= { olAgentsEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.49.2.3.1.1.3.1.1 | olAgentsSlotIndex | 0 | 0 | The slot number that contains this agent. |
1.3.6.1.4.1.49.2.3.1.1.3.1.2 | olAgentsStationAddr | 0 | 0 | The unique identifier for this agent. Often this is the value of ifPhysAddress for the first interface. |
1.3.6.1.4.1.49.2.3.1.1.3.1.3 | olAgentsIpAddress | 0 | 0 | An IP Address that can be used to communicate to this agent. Note, this object's value may change as the agent switches to diffe… |
1.3.6.1.4.1.49.2.3.1.1.3.1.4 | olAgentsMasterStatus | 0 | 0 | The mastership status of this agent. |
1.3.6.1.4.1.49.2.3.1.1.3.1.6 | ocAgentsSubSlot | 0 | 0 | The subslot index for this agent. For agents not located in the ONcore system, this object will always return 1 for this object … |