When both connectors are on the same network:
Setting this object to connector-1 allows the EMM to
monitor the port statistics of port 1-12 on a per-port
basis, and the port statistics of port 13-24 are summed
and are reported through port 13.
Setting this object to connector-2 allows the EMM to
monitor the port statistics of port 12-24 on a per-port
basis, and the port statistics of port 1-12 are summed
and are reported through port 13.
Note: when the 2 connectors are on different networks,
setting this object to the value connector-1 or
connector-2 will not have any effect. The port counters
will be cleared whenever the value of this object is
changed.
Parsed from file isd_mib.txt
Company: None
Module: CHIPCOMMIB
When both connectors are on the same network:
Setting this object to connector-1 allows the EMM to
monitor the port statistics of port 1-12 on a per-port
basis, and the port statistics of port 13-24 are summed
and are reported through port 13.
Setting this object to connector-2 allows the EMM to
monitor the port statistics of port 12-24 on a per-port
basis, and the port statistics of port 1-12 are summed
and are reported through port 13.
Note: when the 2 connectors are on different networks,
setting this object to the value connector-1 or
connector-2 will not have any effect. The port counters
will be cleared whenever the value of this object is
changed.
Parsed from file CHIPCOMMIB.mib
Module: CHIPCOMMIB
Vendor: Chippcom
Module: CHIPCOMMIB
[Automatically extracted from oidview.com]
ol51nnMTPCLModMonitorConn OBJECT-TYPE SYNTAX INTEGER { connector-1(1), connector-2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When both connectors are on the same network: Setting this object to connector-1 allows the EMM to monitor the port statistics of port 1-12 on a per-port basis, and the port statistics of port 13-24 are summed and are reported through port 13. Setting this object to connector-2 allows the EMM to monitor the port statistics of port 12-24 on a per-port basis, and the port statistics of port 1-12 are summed and are reported through port 13. Note: when the 2 connectors are on different networks, setting this object to the value connector-1 or connector-2 will not have any effect. The port counters will be cleared whenever the value of this object is changed." ::= { ol51nnMTPCLModEntry 2 }
ol51nnMTPCLModMonitorConn OBJECT-TYPE SYNTAX INTEGER { connector-1(1), connector-2(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When both connectors are on the same network: Setting this object to connector-1 allows the EMM to monitor the port statistics of port 1-12 on a per-port basis, and the port statistics of port 13-24 are summed and are reported through port 13. Setting this object to connector-2 allows the EMM to monitor the port statistics of port 12-24 on a per-port basis, and the port statistics of port 1-12 are summed and are reported through port 13. Note: when the 2 connectors are on different networks, setting this object to the value connector-1 or connector-2 will not have any effect. The port counters will be cleared whenever the value of this object is changed." ::= { ol51nnMTPCLModEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.1 | ol51nnMTPCLModSlotIndex | 0 | 0 | The slot number of this module. |
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.3 | ol51nnMTPCLModConn1Network | 0 | 0 | The network that this connector is attached to. |
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.4 | ol51nnMTPCLModConn2Network | 0 | 0 | The network that this connector is attached to. |
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.5 | ol51nnMTPCLModConn1DipNetwork | 0 | 0 | The network indicated by the connector dip switch. |
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.6 | ol51nnMTPCLModConn2DipNetwork | 0 | 0 | The network indicated by the connector dip switch. |
1.3.6.1.4.1.49.2.3.1.4.4.29.1.1.7 | ol51nnMTPCLModAutoPartition | 0 | 0 | This object holds the consecutive collision count limit value. The module goes into the auto-partition mode whenever the consecu… |