Establishes the operational status (enabled or disabled) of the logging
device within the chassis. If enabled, the Common Console will send
system-generated messages to a log located in 'cxCcLogDeviceSlot'.
Options:
disabled (1): no events written to the log file
enabled (2): events written to the log file
Default Value: enabled (2)
Related Objects:
cxCcLogDeviceSlot
Configuration Changed: operative
Parsed from file CXCC.MIB.txt
Company: None
Module: CXCommonConsole-MIB
Establishes the operational status (enabled or disabled) of the logging
device within the chassis. If enabled, the Common Console will send
system-generated messages to a log located in 'cxCcLogDeviceSlot'.
Options:
disabled (1): no events written to the log file
enabled (2): events written to the log file
Default Value: enabled (2)
Related Objects:
cxCcLogDeviceSlot
Configuration Changed: operative
Parsed from file CXCommonConsole-MIB.mib
Module: CXCommonConsole-MIB
Vendor: Memotec Communications
Module: CXCommonConsole-MIB
[Automatically extracted from oidview.com]
cxCcLogDevice OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Establishes the operational status (enabled or disabled) of the logging device within the chassis. If enabled, the Common Console will send system-generated messages to a log located in 'cxCcLogDeviceSlot'. Options: disabled (1): no events written to the log file enabled (2): events written to the log file Default Value: enabled (2) Related Objects: cxCcLogDeviceSlot Configuration Changed: operative" DEFVAL { enabled } ::= { cxCommonConsole 4 }
cxCcLogDevice OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Establishes the operational status (enabled or disabled) of the logging device within the chassis. If enabled, the Common Console will send system-generated messages to a log located in 'cxCcLogDeviceSlot'. Options: disabled (1): no events written to the log file enabled (2): events written to the log file Default Value: enabled (2) Related Objects: cxCcLogDeviceSlot Configuration Changed: operative" DEFVAL { enabled } ::= { cxCommonConsole 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.5.14.4.0 | cxCcLogDevice | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.5.14.1 | cxCcInactivityTimer | 1 | 1 | Determines the amount of time (in seconds) that the Common Console will wait for input before terminating a user session. The us… |
1.3.6.1.4.1.495.2.1.5.14.2 | cxCcPassword | 1 | 1 | Determines the password required to logon through the CX1000 console port to the Common Console module. The password must be bet… |
1.3.6.1.4.1.495.2.1.5.14.3 | cxCcPrompt | 1 | 1 | Determines the prompt that will appear after logging on to and establishing a session with the Common Console to prompt the user… |
1.3.6.1.4.1.495.2.1.5.14.5 | cxCcLogDeviceSlot | 1 | 1 | Establishes the physical slot number in the local chassis where the logging device is located. All log messages produced locally… |
1.3.6.1.4.1.495.2.1.5.14.6 | cxCcQueueDepth | 1 | 1 | Determines the maximum number of log messages that are retained in the console device output when the console device is flow-con… |
1.3.6.1.4.1.495.2.1.5.14.7 | cxCcRemoteTable | 1 | 4 | A table containing the locally defined network access required to connect to the remote Common Console module. |