Reference record for OID 1.3.6.1.4.1.495.2.1.6.30.21.1.14



parent
1.3.6.1.4.1.495.2.1.6.30.21.1 (asyProfEntry)
node code
14
node name
asyProfParameter10
dot oid
1.3.6.1.4.1.495.2.1.6.30.21.1.14
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxAsync(30) asyProfTable(21) asyProfEntry(1) asyProfParameter10(14)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • /iso/identified-organization/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • /iso/org/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • /iso/org/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • /iso/iso-identified-organization/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • /iso/iso-identified-organization/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxAsync/asyProfTable/asyProfEntry/asyProfParameter10
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/495/2/1/6/30/21/1/14

    Description by mibdepot

    Defines the X.3 parameter 10, Line folding. This parameter provides for
    the automatic insertion of graphic characters by the PAD in the character
    stream transmitted to the start-stop mode DTE (user). The predetermined
    maximum number of graphic characters per line may be set.

    Range of Values: 0 to 255

    0: No line folding
    1 to 255: Number of graphic characters per line

    Default Value: 0

    Configuration Changed: Operative

    Parsed from file CXASYNC.MIB.txt
    Company: None
    Module: CXAsync-MIB

    Description by circitor

    Defines the X.3 parameter 10, Line folding. This parameter provides for
    the automatic insertion of graphic characters by the PAD in the character
    stream transmitted to the start-stop mode DTE (user). The predetermined
    maximum number of graphic characters per line may be set.

    Range of Values: 0 to 255

    0: No line folding
    1 to 255: Number of graphic characters per line

    Default Value: 0

    Configuration Changed: Operative

    Parsed from file CXAsync-MIB.mib
    Module: CXAsync-MIB

    Information by oid_info

    Vendor: Memotec Communications
    Module: CXAsync-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    asyProfParameter10 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the X.3 parameter 10, Line folding. This parameter provides for the automatic insertion of graphic characters by the PAD in the character stream transmitted to the start-stop mode DTE (user). The predetermined maximum number of graphic characters per line may be set. Range of Values: 0 to 255 0: No line folding 1 to 255: Number of graphic characters per line Default Value: 0 Configuration Changed: Operative " REFERENCE "CCITT X.3 Table 1" DEFVAL { 0 } ::= { asyProfEntry 14 }

    Information by circitor

    asyProfParameter10 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the X.3 parameter 10, Line folding. This parameter provides for the automatic insertion of graphic characters by the PAD in the character stream transmitted to the start-stop mode DTE (user). The predetermined maximum number of graphic characters per line may be set. Range of Values: 0 to 255 0: No line folding 1 to 255: Number of graphic characters per line Default Value: 0 Configuration Changed: Operative " REFERENCE "CCITT X.3 Table 1" DEFVAL { 0 } ::= { asyProfEntry 14 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.495)

    Turcott Michel

    Brothers (30)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.495.2.1.6.30.21.1.1 asyProfNumber 0 0 Identifies the profile SAP (service access point) using a unique numerical value.
    1.3.6.1.4.1.495.2.1.6.30.21.1.2 asyProfRowStatus 0 0 Indicates whether or not this specific entry is configured within the MIB.

    Options:
    invalid (1): Row is flagged and deleted from …
    1.3.6.1.4.1.495.2.1.6.30.21.1.3 asyProfAlias 0 0 Identifies the SAP (service access point) using a unique textual name.

    Range of Values: 1 to 16 alphanumeric characters beginnin…
    1.3.6.1.4.1.495.2.1.6.30.21.1.5 asyProfParameter1 0 0 Defines the X.3 parameter 1, PAD recall using a character. This parameter
    allows the start-stop mode DTE (user) to initiate an …
    1.3.6.1.4.1.495.2.1.6.30.21.1.6 asyProfParameter2 0 0 Defines the X.3 parameter 2, Echo. This parameter provides for characters
    received from the start-stop mode DTE (user) to be tr…
    1.3.6.1.4.1.495.2.1.6.30.21.1.7 asyProfParameter3 0 0 Defines the X.3 parameter 3, Selection of data forwarding character(s). This
    parameter allows the selection of defined sets of …
    1.3.6.1.4.1.495.2.1.6.30.21.1.8 asyProfParameter4 0 0 Defines the X.3 parameter 4, Selection of idle timer delay, in tenths of a
    second. This parameter allows the selection of the d…
    1.3.6.1.4.1.495.2.1.6.30.21.1.9 asyProfParameter5 0 0 Defines the X.3 parameter 5, Ancillary device control. This parameter allows
    for flow control between the PAD and the start-sto…
    1.3.6.1.4.1.495.2.1.6.30.21.1.10 asyProfParameter6 0 0 Defines the X.3 parameter 6, Control of PAD service signals and PAD command
    signals. This parameter provides the start-stop mod…
    1.3.6.1.4.1.495.2.1.6.30.21.1.11 asyProfParameter7 0 0 Defines the X.3 parameter 7, Selection of operation of the PAD on receipt of a
    break signal from the start-stop mode DTE. This …
    1.3.6.1.4.1.495.2.1.6.30.21.1.12 asyProfParameter8 0 0 Defines the X.3 parameter 8, Discard output. This parameter provides for a
    PAD to discard the content of user sequences in pack…
    1.3.6.1.4.1.495.2.1.6.30.21.1.13 asyProfParameter9 0 0 Defines the X.3 parameter 9, Padding after carriage return (CR). This
    parameter provides for the automatic insertion of padding…
    1.3.6.1.4.1.495.2.1.6.30.21.1.15 asyProfParameter11 0 0 Defines the X.3 parameter 11, Binary
    speed of start-stop mode DTE.

    Options:
    0: 110 bit/s
    1: 134.5 bit/s
    2: 300 bit/s
    3: 1200 bit/s
    4: …
    1.3.6.1.4.1.495.2.1.6.30.21.1.16 asyProfParameter12 0 0 Defines the X.3 parameter 12, Flow control of the PAD. This parameter
    allows for flow control between the start-stop mode DTE (…
    1.3.6.1.4.1.495.2.1.6.30.21.1.17 asyProfParameter13 0 0 Defines the X.3 parameter 13, Linefeed insertion after carriage return. This
    parameter allows for the automatic insertion of a …
    1.3.6.1.4.1.495.2.1.6.30.21.1.18 asyProfParameter14 0 0 Defines the X.3 parameter 14, Padding after linefeed. This parameter provides
    for the automatic insertion of padding characters…
    1.3.6.1.4.1.495.2.1.6.30.21.1.19 asyProfParameter15 0 0 Defines the X.3 parameter 15, Editing. This parameter provides for character
    size delete, line delete and line display editing c…
    1.3.6.1.4.1.495.2.1.6.30.21.1.20 asyProfParameter16 0 0 Defines the X.3 parameter 16, Character delete.

    Range of Values: 0 to 127

    0 to126: One character from IA5
    127: Character 7/15 (DEL…
    1.3.6.1.4.1.495.2.1.6.30.21.1.21 asyProfParameter17 0 0 Defines the X.3 parameter 17, Line delete.

    Range of Values: 0 to 127

    0 to 23: One character from the range of IA5
    24: Character 1…
    1.3.6.1.4.1.495.2.1.6.30.21.1.22 asyProfParameter18 0 0 Defines the X.3 parameter 18, Line display.

    Range of Values: 0 to 127

    0 to 17: One character from the range of IA5
    18: Character 1…
    1.3.6.1.4.1.495.2.1.6.30.21.1.23 asyProfParameter19 0 0 Defines the X.3 parameter 19, Editing PAD service signals. This parameter
    provides the start-stop mode DTE (user) with the abil…
    1.3.6.1.4.1.495.2.1.6.30.21.1.24 asyProfParameter20 0 0 Defines the X.3 parameter 20, Echo mask. This parameter allows selected
    defined sets of characters received from the start-stop…
    1.3.6.1.4.1.495.2.1.6.30.21.1.25 asyProfParameter21 0 0 Defines the X.3 parameter 21, Parity treatment. This parameter allows the
    PAD to check parity in the data stream from the start…
    1.3.6.1.4.1.495.2.1.6.30.21.1.26 asyProfParameter22 0 0 Defines the X.3 parameter 22, Page wait. This parameter allows the PAD to
    suspend transmission of additional characters to the …
    1.3.6.1.4.1.495.2.1.6.30.21.1.27 asyProfParameter23 0 0 Defines parameter 23 (extension to X.3), Receive parity type.

    Options:
    0: Parity disable
    1: Even parity
    2: Odd parity
    3: Space parit…
    1.3.6.1.4.1.495.2.1.6.30.21.1.28 asyProfParameter24 0 0 Defines parameter 24 (extension to
    X.3), Transmit parity type.

    Options:
    0: Parity disable
    1: Even parity
    2: Odd parity
    3: Space parit…
    1.3.6.1.4.1.495.2.1.6.30.21.1.29 asyProfParameter25 0 0 Defines parameter 25 (extension to X.3), Flow control on character to PAD.

    Range of Values: 0 to 127

    Note:
    0 to 18: One character …
    1.3.6.1.4.1.495.2.1.6.30.21.1.30 asyProfParameter26 0 0 Defines parameter 26 (extension to X.3), Flow control off character to PAD.

    Range of Values: 0 to 127

    0 to 16: One character from…
    1.3.6.1.4.1.495.2.1.6.30.21.1.31 asyProfParameter27 0 0 Defines parameter 27 (extension to X.3), Flow control on character to
    ancillary device.

    Range of Values: 0 to 127

    Note:
    0 to 18: On…
    1.3.6.1.4.1.495.2.1.6.30.21.1.32 asyProfParameter28 0 0 Defines parameter 28 (extension to X.3), Flow control off character to
    ancillary device.

    Range of Values: 0 to 127