Reference record for OID 1.3.6.1.4.1.495.2.1.6.37.2.1.11



parent
1.3.6.1.4.1.495.2.1.6.37.2.1 (sdlcCuEntry)
node code
11
node name
sdlcCuSlowPollTimer
dot oid
1.3.6.1.4.1.495.2.1.6.37.2.1.11
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) 495(495) memotecProducts(2) cxProduct(1) cxApplication(6) cxSDLC(37) sdlcCuTable(2) sdlcCuEntry(1) sdlcCuSlowPollTimer(11)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • /iso/identified-organization/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • /iso/org/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • /iso/org/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • /iso/iso-identified-organization/dod/internet/private/enterprise/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • /iso/iso-identified-organization/dod/internet/private/enterprises/495/memotecProducts/cxProduct/cxApplication/cxSDLC/sdlcCuTable/sdlcCuEntry/sdlcCuSlowPollTimer
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/495/2/1/6/37/2/1/11

    Description by mibdepot

    This object applies only if this entry is associated with a TIU service
    access point.

    Determines the amount of time the TIU waits for the control unit
    (secondary link station) to respond to a SNRM poll during slow polling.
    Each time this timer expires another poll is sent. The object
    sdlcCuMaxRetry determines how many slow polls are transmitted.

    The TIU begins slow polling if the sdlcCuPollAckTimer timer expires before
    the control unit has responded to the initial SNRM, XID, or DISC poll.

    Range of Values: 1 - 250 tenths of a second (a value of 0 disables the
    timer)

    Default Value: 10 (1 second)

    Related Objects: sdlcCuPollAckTimer sdlcCuMaxRetry

    Configuration Changed: administrative and operative

    Parsed from file CXSDLC.MIB.txt
    Company: None
    Module: CXSDLC-MIB

    Description by circitor

    This object applies only if this entry is associated with a TIU service
    access point.

    Determines the amount of time the TIU waits for the control unit
    (secondary link station) to respond to a SNRM poll during slow polling.
    Each time this timer expires another poll is sent. The object
    sdlcCuMaxRetry determines how many slow polls are transmitted.

    The TIU begins slow polling if the sdlcCuPollAckTimer timer expires before
    the control unit has responded to the initial SNRM, XID, or DISC poll.

    Range of Values: 1 - 250 tenths of a second (a value of 0 disables the
    timer)

    Default Value: 10 (1 second)

    Related Objects: sdlcCuPollAckTimer sdlcCuMaxRetry

    Configuration Changed: administrative and operative

    Parsed from file CXSDLC-MIB.mib
    Module: CXSDLC-MIB

    Information by oid_info

    Vendor: Memotec Communications
    Module: CXSDLC-MIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    sdlcCuSlowPollTimer OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "This object applies only if this entry is associated with a TIU service access point. Determines the amount of time the TIU waits for the control unit (secondary link station) to respond to a SNRM poll during slow polling. Each time this timer expires another poll is sent. The object sdlcCuMaxRetry determines how many slow polls are transmitted. The TIU begins slow polling if the sdlcCuPollAckTimer timer expires before the control unit has responded to the initial SNRM, XID, or DISC poll. Range of Values: 1 - 250 tenths of a second (a value of 0 disables the timer) Default Value: 10 (1 second) Related Objects: sdlcCuPollAckTimer sdlcCuMaxRetry Configuration Changed: administrative and operative" DEFVAL {10} ::= { sdlcCuEntry 11 }

    Information by circitor

    sdlcCuSlowPollTimer OBJECT-TYPE SYNTAX TimeTicks ACCESS read-write STATUS mandatory DESCRIPTION "This object applies only if this entry is associated with a TIU service access point. Determines the amount of time the TIU waits for the control unit (secondary link station) to respond to a SNRM poll during slow polling. Each time this timer expires another poll is sent. The object sdlcCuMaxRetry determines how many slow polls are transmitted. The TIU begins slow polling if the sdlcCuPollAckTimer timer expires before the control unit has responded to the initial SNRM, XID, or DISC poll. Range of Values: 1 - 250 tenths of a second (a value of 0 disables the timer) Default Value: 10 (1 second) Related Objects: sdlcCuPollAckTimer sdlcCuMaxRetry Configuration Changed: administrative and operative" DEFVAL {10} ::= { sdlcCuEntry 11 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.495)

    Turcott Michel

    Brothers (35)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.495.2.1.6.37.2.1.1 sdlcCuSap 0 0 Determines the sdlcSapNumber of the SAP (service access point) this row
    (control unit) is associated with. More than one seconda…
    1.3.6.1.4.1.495.2.1.6.37.2.1.2 sdlcCuId 0 0 Determines the address of the control unit associated with this SAP. If
    this SAP is a TIU, it defines the address of the physica…
    1.3.6.1.4.1.495.2.1.6.37.2.1.3 sdlcCuRowStatus 0 0 Determines the status of the objects in a table row.

    Options:
    invalid (1): Row is flagged, after next reset the values will be di…
    1.3.6.1.4.1.495.2.1.6.37.2.1.4 sdlcCuMaxFrameLength 0 0 Determines the largest frame that can be sent and received by this
    control unit. The value of this object must match the setting…
    1.3.6.1.4.1.495.2.1.6.37.2.1.5 sdlcCuTransmitWindow 0 0 Determines the maximum number of information frames that can be
    outstanding at any given time. A frame is considered to be outst…
    1.3.6.1.4.1.495.2.1.6.37.2.1.6 sdlcCuPollRetry 0 0 This object applies only if this entry is associated with a TIU service
    access point.

    Determines the number of times an unacknowl…
    1.3.6.1.4.1.495.2.1.6.37.2.1.7 sdlcCuMaxRetry 0 0 This object applies only if this entry is associated with a TIU service
    access point.

    Determines the number of times an unacknowl…
    1.3.6.1.4.1.495.2.1.6.37.2.1.8 sdlcCuWaitForNextSnrmOrXid 0 0 This object applies only if this entry is associated with an HIU service
    access point.

    Determines what the HIU does when it recei…
    1.3.6.1.4.1.495.2.1.6.37.2.1.9 sdlcCuSendDisconnect 0 0 Determines the command that is sent to disconnect the control unit.

    Options:
    no (1): A SNRM is sent to disconnect the control uni…
    1.3.6.1.4.1.495.2.1.6.37.2.1.10 sdlcCuPollAckTimer 0 0 This object applies only if this entry is associated with a TIU service
    access point.

    Defines the amount of time the TIU waits fo…
    1.3.6.1.4.1.495.2.1.6.37.2.1.13 sdlcCuWaitForUaFromSnalcTimer 0 0 If this entry is associated with an HIU SAP (service access point), it
    determines the maximum amount of time that the HIU waits …
    1.3.6.1.4.1.495.2.1.6.37.2.1.30 sdlcCuControl 0 0 Clears all statistics for this control unit.

    Default Value: none

    Options:
    clearStats (1): Clear statistics.

    Configuration Changed: …
    1.3.6.1.4.1.495.2.1.6.37.2.1.40 sdlcCuState 0 0 Indicates the current status of the control unit.

    Options:
    normalDiscMode (1): This control unit is in Normal Disconnected Mode

    wa…
    1.3.6.1.4.1.495.2.1.6.37.2.1.41 sdlcCuOperationalMode 0 0 Indicates the state of this control unit.

    Options:
    offLine (1): Indicates that this control unit is not operational.

    onLine (2): I…
    1.3.6.1.4.1.495.2.1.6.37.2.1.42 sdlcCuDiscReasonCode 0 0 Provides the reason code which indicates why this SLDC control unit was
    disconnected.
    1.3.6.1.4.1.495.2.1.6.37.2.1.43 sdlcCuSnalcDiscReasonCode 0 0 Provides the reason code which indicates why the SNA Link Conversion
    layer disconnected this SLDC control unit.
    1.3.6.1.4.1.495.2.1.6.37.2.1.44 sdlcCuConnectionStatus 0 0 Indicates the state of the SNA link convergence connection for this
    control unit.

    Options:
    up (1): Indicates that the SNA link con…
    1.3.6.1.4.1.495.2.1.6.37.2.1.50 sdlcCuFramesInTransmitQueue 0 0 Indicates the number of frames currently in the transmit queue for this
    control unit. The number of frames should be less than
    sd…
    1.3.6.1.4.1.495.2.1.6.37.2.1.51 sdlcCuTxFrames 0 0 If associated with a TIU service access point, this object indicates the
    number of information frames transmitted to this contro…
    1.3.6.1.4.1.495.2.1.6.37.2.1.52 sdlcCuRxFrames 0 0 If associated with a TIU service access point, this object indicates the
    number of information frames received from this control…
    1.3.6.1.4.1.495.2.1.6.37.2.1.55 sdlcCuTimeOuts 0 0 This object applies only if this entry is associated with a TIU service
    access point.

    Indicates the number of times the sdlcCuPol…
    1.3.6.1.4.1.495.2.1.6.37.2.1.56 sdlcCuSnrmCount 0 0 If associated with a TIU service access point, this object indicates the
    number of SNRM frames transmitted to this control unit.…
    1.3.6.1.4.1.495.2.1.6.37.2.1.57 sdlcCuXidCommand 0 0 If associated with a TIU service access point, this object indicates the
    number of XID frames transmitted to this control unit.

    I…
    1.3.6.1.4.1.495.2.1.6.37.2.1.58 sdlcCuXidResponse 0 0 If associated with a TIU service access point, this object indicates the
    number of SNRM frames transmitted to this control unit.…
    1.3.6.1.4.1.495.2.1.6.37.2.1.59 sdlcCuUnnumberedAcks 0 0 If associated with a TIU service access point, this object indicates the
    number of UA responses received from this control unit.…
    1.3.6.1.4.1.495.2.1.6.37.2.1.60 sdlcCuRetransmission 0 0 If associated with a TIU service access point, this object indicates the
    number of information frames retransmitted to this cont…
    1.3.6.1.4.1.495.2.1.6.37.2.1.61 sdlcCuDisconnectCount 0 0 If associated with a TIU service access point, this object indicates the
    number of DISC commands transmitted to this control uni…
    1.3.6.1.4.1.495.2.1.6.37.2.1.62 sdlcCuDisconnectModeCount 0 0 This object applies only if this entry is associated with a TIU service
    access point.

    Indicates the total number of DM (disconnec…
    1.3.6.1.4.1.495.2.1.6.37.2.1.63 sdlcCuTransmittedRNR 0 0 If associated with a TIU service access point, this object indicates the
    number of RNR frames transmitted to this control unit.

    I…
    1.3.6.1.4.1.495.2.1.6.37.2.1.64 sdlcCuReceivedRNR 0 0 If associated with a TIU service access point, this object indicates the
    number of RNR frames received from this control unit.

    If…
    1.3.6.1.4.1.495.2.1.6.37.2.1.65 sdlcCuFrameRejects 0 0 If associated with a TIU service access point, this object indicates the
    number of FRMR response commands received from this con…
    1.3.6.1.4.1.495.2.1.6.37.2.1.66 sdlcCuRemoteDisc 0 0 This object applies only if this entry is associated with an TIU service
    access point.

    Indicates the number of DISC frames transm…
    1.3.6.1.4.1.495.2.1.6.37.2.1.67 sdlcCuConnectionRequest 0 0 Indicates the number of connections requested by the SNA link conversion
    layer for this control unit.
    1.3.6.1.4.1.495.2.1.6.37.2.1.68 sdlcCuDisconnectionRequest 0 0 Indicates the number of connection clear requests sent by the SNA link
    conversion layer for this control unit.
    1.3.6.1.4.1.495.2.1.6.37.2.1.69 sdlcCuDisconnectionIndication 0 0 Indicates the number of connection cleared messages sent to the SNA link
    conversion layer for this control unit.