The parameters for a specific DSL control block.
Parsed from file CXBCM.MIB.txt
Company: None
Module: CXBCM-MIB
The parameters for a specific DSL control block.
Parsed from file CXBCM-MIB.mib
Module: CXBCM-MIB
Vendor: Memotec Communications
Module: CXBCM-MIB
[Automatically extracted from oidview.com]
bcmDslEntry OBJECT-TYPE SYNTAX BcmDslEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a specific DSL control block." INDEX { bcmDslNumber } ::= { bcmDslTable 1 }
bcmDslEntry OBJECT-TYPE SYNTAX BcmDslEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a specific DSL control block." INDEX { bcmDslNumber } ::= { bcmDslTable 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.6.48.51.1.1 | bcmDslNumber | 0 | 0 | Indicates the Digital Subscriber Line's access point number. Range of Values: 1-2 for DI600 (port) 1-6 for CX900 (slot) 1-8 for CX… |
1.3.6.1.4.1.495.2.1.6.48.51.1.2 | bcmDslRowStatus | 0 | 0 | Determines whether this DSL is to be removed from service (i.e. invalidated) within the B-Channel Manager software layer. Option… |
1.3.6.1.4.1.495.2.1.6.48.51.1.10 | bcmDslSwitchType | 0 | 0 | bcmDslSwitchtype |
1.3.6.1.4.1.495.2.1.6.48.51.1.11 | bcmDslBChannelCount | 0 | 0 | Determines the total number of B channels managed by the signaling interface. Range of Values: 1-30 NOTE: It has to be set to: 2 … |
1.3.6.1.4.1.495.2.1.6.48.51.1.12 | bcmDslBChannelType | 0 | 0 | Determines the type of ISDN line. Options: dialup (1): B channels controlled by associated signaling D channel leased (2): B chann… |
1.3.6.1.4.1.495.2.1.6.48.51.1.13 | bcmDslMngmtTimer | 0 | 0 | Determines the interval in seconds that the BCM software layer will wait between two SPIDs transmission when no answer form the n… |
1.3.6.1.4.1.495.2.1.6.48.51.1.14 | bcmDslInfoRate | 0 | 0 | Determines the speed of the B channel connected to the Digital Subscriber Line when a call is initiated on that DSL. Options: rate… |
1.3.6.1.4.1.495.2.1.6.48.51.1.15 | bcmDslSendingProceed | 0 | 0 | Indicates the way calling information for the switch is generated. 'en_bloc' means that all calling information is sent in the f… |
1.3.6.1.4.1.495.2.1.6.48.51.1.40 | bcmDslInterfaceType | 0 | 0 | Indicates the type of physical interface for the specified Digital Subscriber Line. Options: none (1): not specified bri (2): Basic… |
1.3.6.1.4.1.495.2.1.6.48.51.1.41 | bcmDslBriType | 0 | 0 | Indicates the type of BRI interface for the specified Digital Subscriber Line. Options: none (1): SAP has no BRI interface u (2): B… |
1.3.6.1.4.1.495.2.1.6.48.51.1.42 | bcmDslPriType | 0 | 0 | Indicates the type of PRI interface for the specified Digital Subscriber Line. Options: none (1): SAP has no PRI interface ansi (2)… |
1.3.6.1.4.1.495.2.1.6.48.51.1.43 | bcmDslNbChannelInUse | 0 | 0 | Indicates the number of B channels connected, connecting, or active on this Digital Subscriber Line. Range of Values: 0-2 for BRI… |
1.3.6.1.4.1.495.2.1.6.48.51.1.44 | bcmDslOutGoingCallId | 0 | 0 | Indicates the call ID used in the 'setup' message sent. Range of Values: 8000-FFFF (hexadecimal) Default Value: none |
1.3.6.1.4.1.495.2.1.6.48.51.1.45 | bcmDslEffectiveRetries | 0 | 0 | Indicates the number of times a management request has been sent to initialize the ISDN switch. Range of Values: 0-255 NOTE: Only … |