Determines the size of the frames (in bytes) to be generated for testing
purposes. If the Data Generator is disabled, then this value is ignored.
Range of Values: 18 - 2100 bytes
Default Value: 512 bytes
Configuration Changed: administrative
Further action: to activate changed
value, click on Action in EMS menu
bar, then click on Reset with Save.
Parsed from file CXTRDIO.MIB.txt
Company: None
Module: CXTRDIo-MIB
Determines the size of the frames (in bytes) to be generated for testing
purposes. If the Data Generator is disabled, then this value is ignored.
Range of Values: 18 - 2100 bytes
Default Value: 512 bytes
Configuration Changed: administrative
Further action: to activate changed
value, click on Action in EMS menu
bar, then click on Reset with Save.
Parsed from file CXTRDIo-MIB.mib
Module: CXTRDIo-MIB
Vendor: Memotec Communications
Module: CXTRDIo-MIB
[Automatically extracted from oidview.com]
trdSapAdmGenFrameSize OBJECT-TYPE SYNTAX INTEGER (18..2100) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the size of the frames (in bytes) to be generated for testing purposes. If the Data Generator is disabled, then this value is ignored. Range of Values: 18 - 2100 bytes Default Value: 512 bytes Configuration Changed: administrative Further action: to activate changed value, click on Action in EMS menu bar, then click on Reset with Save." DEFVAL { 512 } ::= { trdSapAdmEntry 10 }
trdSapAdmGenFrameSize OBJECT-TYPE SYNTAX INTEGER (18..2100) ACCESS read-write STATUS mandatory DESCRIPTION "Determines the size of the frames (in bytes) to be generated for testing purposes. If the Data Generator is disabled, then this value is ignored. Range of Values: 18 - 2100 bytes Default Value: 512 bytes Configuration Changed: administrative Further action: to activate changed value, click on Action in EMS menu bar, then click on Reset with Save." DEFVAL { 512 } ::= { trdSapAdmEntry 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.495.2.1.6.51.2.1.1 | trdSapAdmNumber | 0 | 0 | Identifies the service access point by a number. The system assigns each service access point a unique number. |
1.3.6.1.4.1.495.2.1.6.51.2.1.2 | trdSapAdmAlias | 0 | 0 | Determines the textual name (alias) of this service access point. Each service access point is assigned a unique name. Range of V… |
1.3.6.1.4.1.495.2.1.6.51.2.1.3 | trdSapAdmPortSpeed | 0 | 0 | Defines the input and output speed, in bits per second, for the associated hardware port. Options: speed_4_mbps (1): 4 mbps ring s… |
1.3.6.1.4.1.495.2.1.6.51.2.1.4 | trdSapAdmTxBufferQueue | 0 | 0 | Defines the transmit queue length, in number of buffers, for the associated hardware port. The number of buffers is usually equa… |
1.3.6.1.4.1.495.2.1.6.51.2.1.5 | trdSapAdmRxBufferQueue | 0 | 0 | Defines the receive queue length, in number of buffers, for the associated hardware port. The number of buffers is usually equal… |
1.3.6.1.4.1.495.2.1.6.51.2.1.8 | trdSapAdmDataGenerator | 0 | 0 | Determines whether the Data Generator is enabled. The Data Generator is used for testing purposes. Options: disabled (1) enabled (2… |
1.3.6.1.4.1.495.2.1.6.51.2.1.9 | trdSapAdmGenFrames | 0 | 0 | Determines the number of times a frame will be generated for testing purposes. Frames are generated every 50 msec. If the value … |