Integer value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)
Parsed from file gdc7001.mib.txt
Company: None
Module: GDCMP7001-MIB
Integer value which uniquely identifies the MP7001 to which this
entry is applicable. SCinstance is defined to be ssllddcc where:
ss (byte value) - physical shelf slot location (01-32)
ll (byte value) - line number (01-128)
dd (byte value) - drop number (00-31)
cc (byte value) - channel or interface number (always 00)
Parsed from file GDCMP7001-MIB.mib
Module: GDCMP7001-MIB
mp7001DiagIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)" ::= { mp7001DiagEntry 1 }
Vendor: General DataComm, Inc.
Module: GDCMP7001-MIB
[Automatically extracted from oidview.com]
mp7001DiagIndex OBJECT-TYPE SYNTAX SCinstance ACCESS read-only STATUS mandatory DESCRIPTION "Integer value which uniquely identifies the MP7001 to which this entry is applicable. SCinstance is defined to be ssllddcc where: ss (byte value) - physical shelf slot location (01-32) ll (byte value) - line number (01-128) dd (byte value) - drop number (00-31) cc (byte value) - channel or interface number (always 00)" ::= { mp7001DiagEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.10.4.1.1.2 | mp7001TestPattern | 0 | 0 | Test pattern for tests that use the pattern generator. |
1.3.6.1.4.1.498.6.10.4.1.1.3 | mp7001DiagConfig | 0 | 0 | Selects the test to run. noLoop(1) ends the test. |
1.3.6.1.4.1.498.6.10.4.1.1.4 | mp7001TestLimit | 0 | 0 | Selects the duration to run a diagnostic test. The value(1) noLimit signifies that the test should run indefinitely until explic… |
1.3.6.1.4.1.498.6.10.4.1.1.5 | mp7001TestExecutionStatus | 0 | 0 | This variable reports the status of a test. notInTest(1) indicates a test is not running. testInProgress(2) indicates that a t… |
1.3.6.1.4.1.498.6.10.4.1.1.6 | mp7001TestExceptions | 0 | 0 | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. T… |
1.3.6.1.4.1.498.6.10.4.1.1.7 | mp7001TestResults | 0 | 0 | The results of the last diagnostic test. This can be the current test running or the last completed test. Note that the interpre… |
1.3.6.1.4.1.498.6.10.4.1.1.8 | mp7001ResetTestResults | 0 | 0 | Resets the diagnostic error count. |
1.3.6.1.4.1.498.6.10.4.1.1.9 | mp7001DS0Diag | 0 | 0 | Defines a DS0 level diagnostic. Setting this object value to 0 disables a DS0 level diagnostic. Setting this object to a value… |