Supports the action of soft resetting the unit. When this
object is set to reset(1), then the unit performs a soft
reset, whose meaning is specific to the type of unit being
managed. The value of norm(2) will be returned when
the reset is complete.
The value of norm(2) can not be set by management.
Parsed from file sc5002.mib.txt
Company: None
Module: SC5002-MIB
Supports the action of soft resetting the unit. When this
object is set to reset(1), then the unit performs a soft
reset, whose meaning is specific to the type of unit being
managed. The value of norm(2) will be returned when
the reset is complete.
The value of norm(2) can not be set by management.
Parsed from file SC5002-MIB.mib
Module: SC5002-MIB
sc5002SoftReset OBJECT-TYPE SYNTAX INTEGER { reset(1), norm(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(2) will be returned when the reset is complete. The value of norm(2) can not be set by management." ::= { sc5002MaintenanceEntry 2 }
Vendor: General DataComm, Inc.
Module: SC5002-MIB
[Automatically extracted from oidview.com]
sc5002SoftReset OBJECT-TYPE SYNTAX INTEGER { reset(1), norm(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Supports the action of soft resetting the unit. When this object is set to reset(1), then the unit performs a soft reset, whose meaning is specific to the type of unit being managed. The value of norm(2) will be returned when the reset is complete. The value of norm(2) can not be set by management." ::= { sc5002MaintenanceEntry 2 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.6.8.5.1.1.1 | sc5002MaintenanceLineIndex | 0 | 0 | Integer value which uniquely identifies the SC5002 to which this entry is applicable. SCinstance is defined to be ssllddcc where… |
1.3.6.1.4.1.498.6.8.5.1.1.3 | sc5002DefaultInit | 0 | 0 | This is used to allow the NonVolatile Configuration to be set to a factory default state. When this value is set to factoryDefau… |
1.3.6.1.4.1.498.6.8.5.1.1.4 | sc5002NearEndResetStats | 0 | 0 | Supports the action of soft resetting the sc5002NearEndValidIntervals object. When this object is set to reset(2), then the uni… |
1.3.6.1.4.1.498.6.8.5.1.1.5 | sc5002NearEndStatLastInitialized | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until sc5002NearEndValidIntervals was last initialized to zero |
1.3.6.1.4.1.498.6.8.5.1.1.6 | sc5002FarEndResetStats | 0 | 0 | Supports the action of soft resetting the sc5002FarEndValidIntervals object. When this object is set to reset(2), then the unit… |
1.3.6.1.4.1.498.6.8.5.1.1.7 | sc5002FarEndStatLastInitialized | 0 | 0 | Number of seconds from midnight Dec 31, 1969 up until sc5002FarEndValidIntervals was last initialized to zero |
1.3.6.1.4.1.498.6.8.5.1.1.8 | sc5002LedStatus | 0 | 0 | Returns a bitwise snapshot of the front panel LED state. Octet 1 bit 7 - not used bit 6 - ON bit 5 - INSV bit 4 - RSP bit 3 - TMG bit… |
1.3.6.1.4.1.498.6.8.5.1.1.9 | sc5002NearEndValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought o… |
1.3.6.1.4.1.498.6.8.5.1.1.10 | sc5002FarEndValidIntervals | 0 | 0 | The number of previous intervals for which valid data was collected. The value will be 16 unless the interface was brought o… |
1.3.6.1.4.1.498.6.8.5.1.1.11 | sc5002SysUpTime | 0 | 0 | This variable is used to report the elapsed system tick time for conversion to real time at the controller and is not related to … |