The block errors of the last diagnostic test that involved a
Selftest pattern. Reading block errors while a diagnostic
test in running will cause the unit to drop out of test
and invalidate the block errors. Block errors should be read
only after the test is completed. The valid range for block
errors is 0 to 1,023, 65535 will be returned if for any reason
the test was terminated early.
Parsed from file nms520.mib.txt
Company: None
Module: NMS520-MIB
The block errors of the last diagnostic test that involved a
Selftest pattern. Reading block errors while a diagnostic
test in running will cause the unit to drop out of test
and invalidate the block errors. Block errors should be read
only after the test is completed. The valid range for block
errors is 0 to 1,023, 65535 will be returned if for any reason
the test was terminated early.
Parsed from file NMS520-MIB.mib
Module: NMS520-MIB
nms520DiagBlockErrors OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The block errors of the last diagnostic test that involved a Selftest pattern. Reading block errors while a diagnostic test in running will cause the unit to drop out of test and invalidate the block errors. Block errors should be read only after the test is completed. The valid range for block errors is 0 to 1,023, 65535 will be returned if for any reason the test was terminated early." ::= { nms520DiagCfgEntry 5 }
Vendor: General DataComm, Inc.
Module: NMS520-MIB
[Automatically extracted from oidview.com]
nms520DiagBlockErrors OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The block errors of the last diagnostic test that involved a Selftest pattern. Reading block errors while a diagnostic test in running will cause the unit to drop out of test and invalidate the block errors. Block errors should be read only after the test is completed. The valid range for block errors is 0 to 1,023, 65535 will be returned if for any reason the test was terminated early." ::= { nms520DiagCfgEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.498.8.2.6.1.1 | nms520DiagCfgIndex | 0 | 0 | The index value which uniquely identifies the NMS520 to which this entry is applicable. This has the form of a SCinstance which … |
1.3.6.1.4.1.498.8.2.6.1.2 | nms520DiagSendCode | 0 | 0 | Configures the selftest pattern to be run during any diagonostic test involving selftest. If option SendOtherPattern is selected,… |
1.3.6.1.4.1.498.8.2.6.1.3 | nms520DiagTestExceptions | 0 | 0 | Indicates exceptions that have occurred that may affect interpretation of the test results. The value of this object is a sum. T… |
1.3.6.1.4.1.498.8.2.6.1.4 | nms520DiagBitErrors | 0 | 0 | The bit errors of the last diagnostic test that involved a Selftest pattern. Reading bit errors while a diagnostic test in runni… |
1.3.6.1.4.1.498.8.2.6.1.6 | nms520DiagTestReset | 0 | 0 | This object will halt the execution of any and all diagnostic test that may be running with the exception of the Network Delay Te… |
1.3.6.1.4.1.498.8.2.6.1.7 | nms520DiagTimeDelay | 0 | 0 | This object reads the results of a Network Delay Test. The results are valid only after the test is completed which takes about 1… |