The ethernet addresses associated with the indicated circuit,
accessed by index.
Note: The instance identifier for this object is the circuit
number followed by an index. The index has no other meaning
than to be used as an index for the purposes of the GET NEXT
operation.
Parsed from file rrev2-mib.mib.txt
Company: None
Module: REPEATER-MIB-2
The ethernet addresses associated with the indicated circuit,
accessed by index.
Note: The instance identifier for this object is the circuit
number followed by an index. The index has no other meaning
than to be used as an index for the purposes of the GET NEXT
operation.
Parsed from file REPEATER-MIB-2.mib
Module: REPEATER-MIB-2
redundancyCircuitMACAddrDisp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The ethernet addresses associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation." ::= { redundancy 13 }
Vendor: Enterasys Networks Inc.
Module: IRM3-MIB
[Automatically extracted from oidview.com]
redundancyCircuitMACAddrDisp OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The ethernet addresses associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circuit number followed by an index. The index has no other meaning than to be used as an index for the purposes of the GET NEXT operation." ::= { redundancy 13 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.52.1.2.1.8.13.0 | redundancyCircuitMACAddrDisp | 0 | 0 | None |
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.52.1.2.1.8.1 | redundancyPollInterval | 1 | 1 | The number of seconds between polls for redundancy. The minimum is 0 and the maximum is 99. |
1.3.6.1.4.1.52.1.2.1.8.2 | redundancyTestTod | 1 | 1 | The time of day at which the redundant circuits should be tested. |
1.3.6.1.4.1.52.1.2.1.8.3 | redundancyPerformTest | 1 | 1 | A read will return a 0. A set of a 1 will test the redundant circuits now. |
1.3.6.1.4.1.52.1.2.1.8.4 | redundancyCircuitName | 1 | 1 | The name of the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.5 | redundancyRetryCount | 1 | 1 | The number of unanswered polls allowed for the indicated circuit before the current connection is declared bad. The minimum is 0… |
1.3.6.1.4.1.52.1.2.1.8.6 | redundancyNumBPs | 1 | 1 | The number of board/port combinations associated with the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.7 | redundancyCircuitBoard, redundancyCircuitBoards | 1 | 1 | The boards associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circu… |
1.3.6.1.4.1.52.1.2.1.8.8 | redundancyCircuitPort | 1 | 1 | The ports associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is the circui… |
1.3.6.1.4.1.52.1.2.1.8.9 | redundancyCircuitTypes | 1 | 1 | The type of each port associated with the indicated circuit, accessed by index. Note: The instance identifier for this object is… |
1.3.6.1.4.1.52.1.2.1.8.10 | redundancyCircuitNumAddr | 1 | 1 | The number of addresses associated with the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.11 | redundancyCircuitMACAddrAdd | 1 | 1 | A get will return a null string. A set adds an ethernet address to the polling list for the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.12 | redundancyCircuitMACAddrDel | 1 | 1 | A get will return a null string. A set deletes an ethernet address from the polling list for the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.14 | redundancyCircuitEnable | 1 | 1 | Enables and disables the indicated circuit. |
1.3.6.1.4.1.52.1.2.1.8.15 | redundancyCircuitReset | 1 | 1 | A get will return 0. A set of 1 will reset the indicated circuit, return all of the associated board and ports to NOT-USED, remov… |