This object identifies an instance of the type
of Protocol Manager residing on this physical
port. Before a physical port may be used, the type
of manager must be designated. For example, if the
physical port was going to be used as an ISDN PRI
interface, with dial up PPP links, then the manager
type would be set to (4), ISDN-PRI-PPP.
Parsed from file ctron-remote-access-mib.txt
Company: None
Module: CTRON-REMOTE-ACCESS-MIB
This object identifies an instance of the type
of Protocol Manager residing on this physical
port. Before a physical port may be used, the type
of manager must be designated. For example, if the
physical port was going to be used as an ISDN PRI
interface, with dial up PPP links, then the manager
type would be set to (4), ISDN-PRI-PPP.
Parsed from file CTRON-REMOTE-ACCESS-MIB.mib
Module: CTRON-REMOTE-ACCESS-MIB
ctRemPhysPortProtMgrType OBJECT-TYPE SYNTAX INTEGER { none(1), pppNailedUp(2), isdnPriPpp(3), isdnBriPpp(4), frameRelayPvcRtr(5), frameRelayPvcSw(6), hdlc(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies an instance of the type of Protocol Manager residing on this physical port. Before a physical port may be used, the type of manager must be designated. For example, if the physical port was going to be used as an ISDN PRI interface, with dial up PPP links, then the manager type would be set to (4), ISDN-PRI-PPP." DEFVAL { none } ::= { ctRemPhysPortEntry 4 }
Vendor: Enterasys Networks Inc.
Module: CTRON-REMOTE-ACCESS-MIB
[Automatically extracted from oidview.com]
ctRemPhysPortProtMgrType OBJECT-TYPE SYNTAX INTEGER { none(1), pppNailedUp(2), isdnPriPpp(3), isdnBriPpp(4), frameRelayPvcRtr(5), frameRelayPvcSw(6), hdlc(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This object identifies an instance of the type of Protocol Manager residing on this physical port. Before a physical port may be used, the type of manager must be designated. For example, if the physical port was going to be used as an ISDN PRI interface, with dial up PPP links, then the manager type would be set to (4), ISDN-PRI-PPP." DEFVAL { none } ::= { ctRemPhysPortEntry 4 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.1 | ctRemConnectionIndex | 0 | 0 | A value indicating the remote connection this entry is located on. |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.2 | ctRemPhysPortType | 0 | 0 | The type of physical port that this entry describes. None indicates that the physical port has no connector. |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.3 | ctRemPhysPortSpecificMib | 0 | 0 | This object identifies an instance of the index object in the first group of objects in the MIB specific to the physical port. |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.5 | ctRemPhysPortProtMgrIfaceNum | 0 | 0 | This object identifies the interface number that will be assigned to the Protocol Managers IFO |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.6 | ctRemPhysPortWanIfaceNum | 0 | 0 | This object identifies the interface number that will be assigned to the Wanio's IFO |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.7 | ctRemPhysPortProtMgrMaxIfos | 0 | 0 | This object identifies the maximum number of IFO's that can be created on this physical interface. |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.8 | ctRemPhysPortProtMgrIfaceList | 0 | 0 | This object identifies a list of interfaces that will be assigned to this Protocol Managers data IFO's |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.9 | ctRemPhysAlarmTimeOut | 0 | 0 | Whenever the physical port is configured for nailed-up PPP this object specifies the time the physical port must remain in a fail… |
1.3.6.1.4.1.52.4.1.2.7.2.1.2.1.10 | ctRemPhysWpimType | 0 | 0 | This Mib object determines the Mode of operation that the T1/DDS Wpim module will function as. Setting a value of 1 will set the … |