The operational status of this range table entry.
It will be `disabled' if this entry's row status is not active.
It will be `workgroupInvalid' if either there is no workgroup
or if the operational status for the workgroup in the definition
table associated with this address range is not ok.
It will be `interfaceInvalid' if this interface is not in
the workgroup interface table or if operational status of the
interface entry is not ok. It will be `physAddrRequired' if
the security level of the associated workgroup is high and
no physical address has been specified for this entry.
Parsed from file ctip-mib.mib.txt
Company: None
Module: CTRON-IP-ROUTER-MIB
The operational status of this range table entry.
It will be `disabled' if this entry's row status is not active.
It will be `workgroupInvalid' if either there is no workgroup
or if the operational status for the workgroup in the definition
table associated with this address range is not ok.
It will be `interfaceInvalid' if this interface is not in
the workgroup interface table or if operational status of the
interface entry is not ok. It will be `physAddrRequired' if
the security level of the associated workgroup is high and
no physical address has been specified for this entry.
Parsed from file CTRON-IP-ROUTER-MIB.mib
Module: CTRON-IP-ROUTER-MIB
nwIpWgRngOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), disabled(2), workgroupInvalid(3), interfaceInvalid(4), physAddrRequired(5), internalError(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of this range table entry. It will be `disabled' if this entry's row status is not active. It will be `workgroupInvalid' if either there is no workgroup or if the operational status for the workgroup in the definition table associated with this address range is not ok. It will be `interfaceInvalid' if this interface is not in the workgroup interface table or if operational status of the interface entry is not ok. It will be `physAddrRequired' if the security level of the associated workgroup is high and no physical address has been specified for this entry." ::= { nwIpWgRngEntry 6 }
Vendor: Enterasys Networks Inc.
Module: CTRON-IP-ROUTER-MIB
[Automatically extracted from oidview.com]
nwIpWgRngOperStatus OBJECT-TYPE SYNTAX INTEGER { ok(1), disabled(2), workgroupInvalid(3), interfaceInvalid(4), physAddrRequired(5), internalError(6) } ACCESS read-only STATUS mandatory DESCRIPTION "The operational status of this range table entry. It will be `disabled' if this entry's row status is not active. It will be `workgroupInvalid' if either there is no workgroup or if the operational status for the workgroup in the definition table associated with this address range is not ok. It will be `interfaceInvalid' if this interface is not in the workgroup interface table or if operational status of the interface entry is not ok. It will be `physAddrRequired' if the security level of the associated workgroup is high and no physical address has been specified for this entry." ::= { nwIpWgRngEntry 6 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.52.4.2.2.2.3.1.2.11.3.1.1 | nwIpWgRngBegHostAddr | 0 | 0 | The beginning (lower) IP address of the address range. This is the primary index into the IP Work Group Range Table. |
1.3.6.1.4.1.52.4.2.2.2.3.1.2.11.3.1.2 | nwIpWgRngEndHostAddr | 0 | 0 | The ending (higher) IP address of the address range. This is the secondary index of the IP Work Group Range Table. |
1.3.6.1.4.1.52.4.2.2.2.3.1.2.11.3.1.3 | nwIpWgRngIfIndex | 0 | 0 | The interface number. This is the tertiary index into the IP Work Group Interface Table, matching the primary index into the MIB… |
1.3.6.1.4.1.52.4.2.2.2.3.1.2.11.3.1.4 | nwIpWgRngPhysAddr | 0 | 0 | The physical address of the host with the IP address given in the nwIpWgRngBegHostAddr for this conceptual row entry. Only single… |
1.3.6.1.4.1.52.4.2.2.2.3.1.2.11.3.1.5 | nwIpWgRngRowStatus | 0 | 0 | This status instance supports `createAndGo' semantics to create an active entry. |