Threshold value of Cyclic Redundancy Check ( CRC ) Error per second. If set to 0, will not be considered in switching the Clock.
Parsed from file ASCEND-MIBDS1CLKERR-MIB.mib
Module: ASCEND-MIBDS1CLKERR-MIB
Vendor: Ascend Communications Inc.
Module: ASCEND-MIBDS1CLKERR-MIB
[Automatically extracted from oidview.com]
ds1ClockErrorProfile-CrcThreshold OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Threshold value of Cyclic Redundancy Check ( CRC ) Error per second. If set to 0, will not be considered in switching the Clock." ::= { mibds1ClockErrorProfileEntry 3 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.529.23.164.1.1.1 | ds1ClockErrorProfile-Index-o | 0 | 0 | None |
1.3.6.1.4.1.529.23.164.1.1.2 | ds1ClockErrorProfile-Enabled | 0 | 0 | Enables or disables the feature of swapping the master clock source with the next priority source, if it is experiencing errors… |
1.3.6.1.4.1.529.23.164.1.1.4 | ds1ClockErrorProfile-FrameSlipsThreshold | 0 | 0 | Threshold value of Frame Slips Error per second. If set to 0, will not be considered in switching the Clock. |
1.3.6.1.4.1.529.23.164.1.1.5 | ds1ClockErrorProfile-FerThreshold | 0 | 0 | Threshold value of Framing Error ( FER ) per second. If set to 0, will not be considered in switching the Clock. |
1.3.6.1.4.1.529.23.164.1.1.6 | ds1ClockErrorProfile-OofThreshold | 0 | 0 | ds1ClockErrorProfile-Oofthreshold |
1.3.6.1.4.1.529.23.164.1.1.7 | ds1ClockErrorProfile-FebeThreshold | 0 | 0 | Threshold value of Far end block ( FEBE ) Error per second. If set to 0, will not be considered in switching the Clock. |
1.3.6.1.4.1.529.23.164.1.1.8 | ds1ClockErrorProfile-LcvThreshold | 0 | 0 | Threshold value of Line code violations ( LCV ) Error per second. If set to 0, will not be considered in switching the Clock. |