The number of the slot that the addressed physical device resides on.
Parsed from file ASCEND-MIBALARM-MIB.mib
Module: ASCEND-MIBALARM-MIB
Vendor: Ascend Communications Inc.
Module: ASCEND-MIBALARM-MIB
[Automatically extracted from oidview.com]
alarmProfile-PhysicalAddress-Slot OBJECT-TYPE SYNTAX INTEGER { anySlot (1), slot1 (2), slot2 (3), slot3 (4), slot4 (5), slot5 (6), slot6 (7), slot7 (8), slot8 (9), slot9 (10), slot10 (11), slot11 (12), slot12 (13), slot13 (14), slot14 (15), slot15 (16), slot16 (17), slot17 (18), slot18 (19), slot19 (20), slot20 (21), slot21 (22), slot22 (23), slot23 (24), slot24 (25), slot25 (26), slot26 (27), slot27 (28), slot28 (29), slot29 (30), slot30 (31), slot31 (32), slot32 (33), slot33 (34), slot34 (35), slot35 (36), slot36 (37), slot37 (38), slot38 (39), slot39 (40), slot40 (41), aLim (55), bLim (56), cLim (57), dLim (58), leftController (49), rightController (50), controller (42), firstControlModule (53), secondControlModule (54), trunkModule1 (45), trunkModule2 (46), controlModule (51), slotPrimary (59) } ACCESS read-write STATUS mandatory DESCRIPTION "The number of the slot that the addressed physical device resides on." ::= { mibalarmProfileEntry 5 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.529.23.33.1.1.1 | alarmProfile-Name | 0 | 0 | The name consists of a null terminated ascii string supplied by the user |
1.3.6.1.4.1.529.23.33.1.1.2 | alarmProfile-Enabled | 0 | 0 | TRUE if the alarm profile is enabled, otherwise FALSE. |
1.3.6.1.4.1.529.23.33.1.1.3 | alarmProfile-Event | 0 | 0 | Alarm event type |
1.3.6.1.4.1.529.23.33.1.1.4 | alarmProfile-PhysicalAddress-Shelf | 0 | 0 | The number of the shelf that the addressed physical device resides on. |
1.3.6.1.4.1.529.23.33.1.1.6 | alarmProfile-PhysicalAddress-ItemNumber | 0 | 0 | A number that specifies an addressable entity within the context of shelf and slot. |
1.3.6.1.4.1.529.23.33.1.1.7 | alarmProfile-Action-AlarmLedMinor | 0 | 0 | The LED that indicates a minor alarm |
1.3.6.1.4.1.529.23.33.1.1.8 | alarmProfile-Action-AlarmLedMajor | 0 | 0 | The LED that indicates a major alarm |
1.3.6.1.4.1.529.23.33.1.1.9 | alarmProfile-Action-AlarmRelayMinor | 0 | 0 | The relay that is set for a minor alarm |
1.3.6.1.4.1.529.23.33.1.1.10 | alarmProfile-Action-AlarmRelayMinorDuration | 0 | 0 | The duration in seconds for which the minor relay is set |
1.3.6.1.4.1.529.23.33.1.1.11 | alarmProfile-Action-AlarmRelayMajor | 0 | 0 | The relay that is set for a major alarm |
1.3.6.1.4.1.529.23.33.1.1.12 | alarmProfile-Action-AlarmRelayMajorDuration | 0 | 0 | The duration in seconds for which the major relay is set |
1.3.6.1.4.1.529.23.33.1.1.13 | alarmProfile-Action-o | 0 | 0 | None |