Reference record for OID 1.3.6.1.4.1.546.16.6.3


parent
1.3.6.1.4.1.546.16.6 (svcRsp)
node code
3
node name
svcRspModMode
dot oid
1.3.6.1.4.1.546.16.6.3
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprises(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprise(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) empire(546) applications(16) svcRsp(6) svcRspModMode(3)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/empire/applications/svcRsp/svcRspModMode
  • /iso/identified-organization/dod/internet/private/enterprises/empire/applications/svcRsp/svcRspModMode
  • /iso/org/dod/internet/private/enterprise/empire/applications/svcRsp/svcRspModMode
  • /iso/org/dod/internet/private/enterprises/empire/applications/svcRsp/svcRspModMode
  • /iso/iso-identified-organization/dod/internet/private/enterprise/empire/applications/svcRsp/svcRspModMode
  • /iso/iso-identified-organization/dod/internet/private/enterprises/empire/applications/svcRsp/svcRspModMode
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/546/16/6/3

    Description by mibdepot

    This object indicates if the module is in
    full-mode or restricted-mode. Restricted-mode
    is entered, when SystemEDGE 4.0 and higher,
    fails to find a valid license. Once
    a valid license has been allocated and
    set, the module will then transition to
    fullMode(1)

    Parsed from file svcrsp.my.txt
    Company: None
    Module: EMPIRE-SVCRSP

    Description by circitor

    This object indicates if the module is in
    full-mode or restricted-mode. Restricted-mode
    is entered, when SystemEDGE 4.0 and higher,
    fails to find a valid license. Once
    a valid license has been allocated and
    set, the module will then transition to
    fullMode(1)

    Parsed from file EMPIRE-SVCRSP.mib
    Module: EMPIRE-SVCRSP

    Information by oid_info

    Child arc 0 is used to translate between SNMPv1 and SNMPv2 notification parameters as explained in IETF RFC 2576, section 3.

    Information by mibdepot

    svcRspModMode OBJECT-TYPE SYNTAX INTEGER { fullMode(1), restrictedMode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the module is in full-mode or restricted-mode. Restricted-mode is entered, when SystemEDGE 4.0 and higher, fails to find a valid license. Once a valid license has been allocated and set, the module will then transition to fullMode(1)" ::= { svcRsp 3 }

    Information by circitor

    svcRspModMode OBJECT-TYPE SYNTAX INTEGER { fullMode(1), restrictedMode(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This object indicates if the module is in full-mode or restricted-mode. Restricted-mode is entered, when SystemEDGE 4.0 and higher, fails to find a valid license. Once a valid license has been allocated and set, the module will then transition to fullMode(1)" ::= { svcRsp 3 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.546)

    Cheryl Krupczak

    Children (1)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.546.16.6.3.0 svcRspModMode 0 0 None

    Brothers (9)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.546.16.6.1 svcRspVersion 1 1 Description and version number of this module
    1.3.6.1.4.1.546.16.6.2 svcRspPID 1 1 Process ID of the svcrsp sub-program.
    1.3.6.1.4.1.546.16.6.10 svcRspTable 1 49 This table describes the service response time
    measurements being conducted by this Application
    Management Moudle.
    1.3.6.1.4.1.546.16.6.11 svcRspUnusedIndex 1 1 An SNMP Get of this MIB object returns an un-used
    svcrsp Table index number. It can be used
    for svcrsp table row creation optimi…
    1.3.6.1.4.1.546.16.6.12 svcRspMatchDescr 1 1 This MIB object, when used in conjunction with
    svcRspEventMatchIndex can be used to quickly determine the index
    number correspond…
    1.3.6.1.4.1.546.16.6.13 svcRspMatchIndex 1 1 See description for svcRspMatchDescr.
    1.3.6.1.4.1.546.16.6.14 svcRspNumTests 1 1 This is the number of tests currently running on
    the agent. This may be greater than the number seen
    in eHealth, as it includes …
    1.3.6.1.4.1.546.16.6.15 svcRspMaxThreads 1 1 This is the maximum number of threads that the collector
    is allowed to run. Each thread executes a test, so multiple
    threads all…
    1.3.6.1.4.1.546.16.6.16 svcRspSecurityFlags 1 1 This is a bitmask for displaying various security settings:

    Bit 0: Security settings hidden. If this bit is set, all others
    will…