Vendor: Netbotz
Module: NETBOTZ-MIB (netbotz1.mib)
Type: OBJ ID
Access:
Syntax:
Automatically extracted from www.mibdepot.com
netBotz-metric-onboard OBJECT IDENTIFIER ::= { netBotz-metric 10 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.5528.32.10.1 | netBotz-metric-onboard-temp, netBotz-metric-onboard-model | 1 | 1 | The model description of the appliance. |
1.3.6.1.4.1.5528.32.10.2 | netBotz-metric-onboard-humidity | 1 | 1 | The reading of the built-in humidity probe, in percent. |
1.3.6.1.4.1.5528.32.10.3 | netBotz-metric-onboard-airflow | 1 | 1 | The reading of the built-in airflow probe, in meters/minute. |
1.3.6.1.4.1.5528.32.10.4 | netBotz-metric-onboard-audio | 1 | 1 | The reading of the built-in audio alarm probe on/off. |
1.3.6.1.4.1.5528.32.10.5 | netBotz-metric-onboard-doorajar | 1 | 1 | The reading of the door switch probe open(1) or closed(0). |
1.3.6.1.4.1.5528.32.10.6 | netBotz-metric-onboard-temp-min | 1 | 1 | The temperature probe minimum, from 1 to 50 degrees C in tenths of a degree C. |
1.3.6.1.4.1.5528.32.10.7 | netBotz-metric-onboard-temp-max | 1 | 1 | The temperature probe maximum, from 1 to 50 degrees C in tenths of a degree C. |
1.3.6.1.4.1.5528.32.10.8 | netBotz-metric-onboard-humidity-min | 1 | 1 | The humidity probe minimum, from 10 to 90 percent. |
1.3.6.1.4.1.5528.32.10.9 | netBotz-metric-onboard-humidity-max | 1 | 1 | The humidity probe maximum, from 10 to 90 percent. |
1.3.6.1.4.1.5528.32.10.10 | netBotz-metric-onboard-airflow-mins | 1 | 1 | Minutes without airflow before alarm set. |
1.3.6.1.4.1.5528.32.10.11 | netBotz-metric-onboard-audio-secs | 1 | 1 | Seconds of alarm audio before alarm set. |
1.3.6.1.4.1.5528.32.10.12 | netBotz-metric-onboard-switch-state | 1 | 1 | Switch state setting. The state controls which condition of the door switch indicates an alarm. If set to 0, alarm is set whe… |
1.3.6.1.4.1.5528.32.10.13 | netBotz-metric-onboard-audio-level | 1 | 1 | Audio level setting, this is the relative audio level, from 0-11, above which an alarm will be sent. |
1.3.6.1.4.1.5528.32.10.14 | netBotz-metric-onboard-airflow-level | 1 | 1 | Airflow alert level. This is the level, in meters per second, below which an alarm will be sent. |
1.3.6.1.4.1.5528.32.10.15 | netBotz-metric-onboard-cam-motion | 1 | 1 | The current motion reading for the camera motion sensor (0=none, 1=motion detected, -1=not licensed). |
1.3.6.1.4.1.5528.32.10.16 | netBotz-metric-onboard-cam-motion-sensitivity | 1 | 1 | Camera motion sensor sensitivity: 1=max, 15=min, 0=disabled. |
1.3.6.1.4.1.5528.32.10.17 | 17 | 1 | 1 | netBotz-metric-onboard-cam-motion-sensitivity |