Reference record for OID 1.3.6.1.4.1.562.2.4.1.12.6.10.1.2



parent
1.3.6.1.4.1.562.2.4.1.12.6.10.1 (lpE3ProvEntry)
node code
2
node name
lpE3ClockingSource
dot oid
1.3.6.1.4.1.562.2.4.1.12.6.10.1.2
type
OBJECT-TYPE
asn1 oid
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) nortel(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • {iso(1) identified-organization(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • ...skipped...
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) northernTelecom(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprise(1) nt(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) nortel(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • {iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • ...skipped...
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) northernTelecom(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • {iso(1) iso-identified-organization(3) dod(6) internet(1) private(4) enterprises(1) nt(562) magellan(2) passport(4) components(1) lp(12) lpE3(6) lpE3ProvTable(10) lpE3ProvEntry(1) lpE3ClockingSource(2)}
  • iri oid
  • /iso/identified-organization/dod/internet/private/enterprise/nortel/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • /iso/identified-organization/dod/internet/private/enterprise/northernTelecom/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • ...skipped...
  • /iso/org/dod/internet/private/enterprise/northernTelecom/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • /iso/org/dod/internet/private/enterprise/nt/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • /iso/org/dod/internet/private/enterprises/nortel/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • /iso/org/dod/internet/private/enterprises/northernTelecom/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • ...skipped...
  • /iso/iso-identified-organization/dod/internet/private/enterprises/northernTelecom/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • /iso/iso-identified-organization/dod/internet/private/enterprises/nt/magellan/passport/components/lp/lpE3/lpE3ProvTable/lpE3ProvEntry/lpE3ClockingSource
  • iri by oid_info
    /ISO/Identified-Organization/6/1/4/1/562/2/4/1/12/6/10/1/2

    Description by mibdepot

    This attribute defines the type of clocking source used for
    synchronizing the E3 transmit clock: local means direct use of the
    local clock oscillator at its centre frequency; line means use of a
    signal phase-locked to the incoming E3 line rate; module means the
    use of a signal phase-locked to the CP reference clock.
    Note that the multiport cell-based cards have one common clock
    source for each of the three ports. For this reason, the following
    rules apply for the value of clockingSource across the board's three
    ports:
    All three clockingSource values must be 'local' OR
    All three clockingSource values must be 'module' OR
    One clockingSource value must be 'line' and the other two must be
    'otherPort'.
    The default value for this attribute will be module if a CP clock is
    available, and local otherwise.

    Parsed from file nortelPP-logicalProcessorV1_BG00S4C.mib.txt
    Company: None
    Module: Nortel-Magellan-Passport-LogicalProcessorMIB

    Description by circitor

    This attribute defines the type of clocking source used for
    synchronizing the E3 transmit clock: local means direct use of the
    local clock oscillator at its centre frequency; line means use of a
    signal phase-locked to the incoming E3 line rate; module means the
    use of a signal phase-locked to the CP reference clock.
    Note that the multiport cell-based cards have one common clock
    source for each of the three ports. For this reason, the following
    rules apply for the value of clockingSource across the board's three
    ports:
    All three clockingSource values must be 'local' OR
    All three clockingSource values must be 'module' OR
    One clockingSource value must be 'line' and the other two must be
    'otherPort'.
    The default value for this attribute will be module if a CP clock is
    available, and local otherwise.

    Parsed from file Nortel-Magellan-Passport-LogicalProcessorMIB.mib
    Module: Nortel-Magellan-Passport-LogicalProcessorMIB

    Information by oid_info

    Vendor: Northern Telecom, Ltd.
    Module: Nortel-Magellan-Passport-LogicalProcessorMIB

    [Automatically extracted from oidview.com]

    Information by mibdepot

    lpE3ClockingSource OBJECT-TYPE SYNTAX INTEGER { local(0), line(1), module(2), otherPort(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the type of clocking source used for synchronizing the E3 transmit clock: local means direct use of the local clock oscillator at its centre frequency; line means use of a signal phase-locked to the incoming E3 line rate; module means the use of a signal phase-locked to the CP reference clock. Note that the multiport cell-based cards have one common clock source for each of the three ports. For this reason, the following rules apply for the value of clockingSource across the board's three ports: All three clockingSource values must be 'local' OR All three clockingSource values must be 'module' OR One clockingSource value must be 'line' and the other two must be 'otherPort'. The default value for this attribute will be module if a CP clock is available, and local otherwise." ::= { lpE3ProvEntry 2 }

    Information by circitor

    lpE3ClockingSource OBJECT-TYPE SYNTAX INTEGER { local(0), line(1), module(2), otherPort(4) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the type of clocking source used for synchronizing the E3 transmit clock: local means direct use of the local clock oscillator at its centre frequency; line means use of a signal phase-locked to the incoming E3 line rate; module means the use of a signal phase-locked to the CP reference clock. Note that the multiport cell-based cards have one common clock source for each of the three ports. For this reason, the following rules apply for the value of clockingSource across the board's three ports: All three clockingSource values must be 'local' OR All three clockingSource values must be 'module' OR One clockingSource value must be 'line' and the other two must be 'otherPort'. The default value for this attribute will be module if a CP clock is available, and local otherwise." ::= { lpE3ProvEntry 2 }

    First Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Sharon Chisholm

    Current Registration Authority (recovered by parent 1.3.6.1.4.1.562)

    Mike Bobbitt

    Brothers (6)

    OIDNameSub childrenSub Nodes TotalDescription
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.1 lpE3LineLength 0 0 This attribute defines the line length for equalization calculations
    for the E3 line. The line length range is between 0 and 300…
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.3 lpE3ApplicationFramerName 0 0 This attribute defines the link to the software stack. It defines which
    application is running on top of the E3 component.
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.4 lpE3Mapping 0 0 This attribute indicates if ATM cells will be mapped directly into
    the E3 payload, or whether PLCP mapping will be used. The PLC…
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.5 lpE3Framing 0 0 This attribute indicates if the framing mode will be in accordance
    with the CCITT G.751 or G.832 specification. The G832
    componen…
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.6 lpE3LinkAlarmActivationThreshold 0 0 This attribute specifies the time interval between the detection of a
    sustained link failure and the activation of an alarm. It …
    1.3.6.1.4.1.562.2.4.1.12.6.10.1.7 lpE3LinkAlarmScanInterval 0 0 This attribute specifies the alarm scan timer polling interval. It
    determines how frequently the status of the link is monitored…