This attribute defines the interval (in minutes) between which
interim test results are to be displayed. Results are displayed at the
operator console at which the test was started. When the test type is
set to externalLoop, this attribute is ignored. There will be no
display of results if displayInterval is set to 0. This attribute can be
changed anytime.
Parsed from file nortelPP-logicalProcessorV1_BG00S4C.mib.txt
Company: None
Module: Nortel-Magellan-Passport-LogicalProcessorMIB
This attribute defines the interval (in minutes) between which
interim test results are to be displayed. Results are displayed at the
operator console at which the test was started. When the test type is
set to externalLoop, this attribute is ignored. There will be no
display of results if displayInterval is set to 0. This attribute can be
changed anytime.
Parsed from file Nortel-Magellan-Passport-LogicalProcessorMIB.mib
Module: Nortel-Magellan-Passport-LogicalProcessorMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-Magellan-Passport-LogicalProcessorMIB
[Automatically extracted from oidview.com]
lpE1TestDisplayInterval OBJECT-TYPE SYNTAX Unsigned32 (0..30240) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the interval (in minutes) between which interim test results are to be displayed. Results are displayed at the operator console at which the test was started. When the test type is set to externalLoop, this attribute is ignored. There will be no display of results if displayInterval is set to 0. This attribute can be changed anytime." DEFVAL { 5 } ::= { lpE1TestSetupEntry 7 }
lpE1TestDisplayInterval OBJECT-TYPE SYNTAX Unsigned32 (0..30240) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute defines the interval (in minutes) between which interim test results are to be displayed. Results are displayed at the operator console at which the test was started. When the test type is set to externalLoop, this attribute is ignored. There will be no display of results if displayInterval is set to 0. This attribute can be changed anytime." DEFVAL { 5 } ::= { lpE1TestSetupEntry 7 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.1 | lpE1TestPurpose | 0 | 0 | This attribute records the purpose of the test so that the test results can be associated and properly analyzed. |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.2 | lpE1TestType | 0 | 0 | This attribute is the type of test to be run. The available test types include the following: card test sets up an internal loop … |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.3 | lpE1TestFrmSize | 0 | 0 | This attribute defines the size of the test data frames in number of bytes. |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.4 | lpE1TestFrmPatternType | 0 | 0 | This attribute defines the type of data pattern generation to use. The following lists the available pattern types: ccitt32kBitPa… |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.5 | lpE1TestCustomizedPattern | 0 | 0 | This attribute allows a customized 32 bit pattern to be defined for use in the test data frames. This attribute is used when the… |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.6 | lpE1TestDataStartDelay | 0 | 0 | This attribute specifies the time delay (in seconds) between when the test expects the loop to have been set up, to when the tes… |
1.3.6.1.4.1.562.2.4.1.12.8.3.11.1.8 | lpE1TestDuration | 0 | 0 | This attribute is the duration (in minutes) that test data will be transmitted. In the case of an externalLoop, this is the time… |