This attribute specifies the threshold value at which a minor alarm
will be issued based on a sustained average ATM VCC utilization as
indicated by the lastCalculatedVccUtilization attribute. The Set
alarm is issued after 3 minutes of utilization greater than the
threshold. The corresponding Clear alarm is issued after a
subsequent 3 minutes of utilization less than or equal to the
threshold.
The value 200% is used to disable this threshold. For values other
than 200%, the minor alarm threshold must be less than the other
thresholds.
Parsed from file nortelPP-atmTrunksV1_BG00S4C.mib.txt
Company: None
Module: Nortel-Magellan-Passport-AtmTrunksMIB
This attribute specifies the threshold value at which a minor alarm
will be issued based on a sustained average ATM VCC utilization as
indicated by the lastCalculatedVccUtilization attribute. The Set
alarm is issued after 3 minutes of utilization greater than the
threshold. The corresponding Clear alarm is issued after a
subsequent 3 minutes of utilization less than or equal to the
threshold.
The value 200% is used to disable this threshold. For values other
than 200%, the minor alarm threshold must be less than the other
thresholds.
Parsed from file Nortel-Magellan-Passport-AtmTrunksMIB.mib
Module: Nortel-Magellan-Passport-AtmTrunksMIB
Vendor: Northern Telecom, Ltd.
Module: Nortel-Magellan-Passport-AtmTrunksMIB
[Automatically extracted from oidview.com]
trkAtmMinorVccUtilAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..200) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the threshold value at which a minor alarm will be issued based on a sustained average ATM VCC utilization as indicated by the lastCalculatedVccUtilization attribute. The Set alarm is issued after 3 minutes of utilization greater than the threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the threshold. The value 200% is used to disable this threshold. For values other than 200%, the minor alarm threshold must be less than the other thresholds." DEFVAL { 75 } ::= { trkAtmUtilEntry 1 }
trkAtmMinorVccUtilAlarmThreshold OBJECT-TYPE SYNTAX Unsigned32 (0..200) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute specifies the threshold value at which a minor alarm will be issued based on a sustained average ATM VCC utilization as indicated by the lastCalculatedVccUtilization attribute. The Set alarm is issued after 3 minutes of utilization greater than the threshold. The corresponding Clear alarm is issued after a subsequent 3 minutes of utilization less than or equal to the threshold. The value 200% is used to disable this threshold. For values other than 200%, the minor alarm threshold must be less than the other thresholds." DEFVAL { 75 } ::= { trkAtmUtilEntry 1 }
OID | Name | Sub children | Sub Nodes Total | Description |
---|---|---|---|---|
1.3.6.1.4.1.562.2.4.1.60.3.14.1.2 | trkAtmMajorVccUtilAlarmThreshold | 0 | 0 | This attribute specifies the threshold value at which a major alarm will be issued based on a sustained average ATM VCC utilizat… |
1.3.6.1.4.1.562.2.4.1.60.3.14.1.3 | trkAtmCriticalVccUtilAlarmThreshold | 0 | 0 | This attribute specifies the threshold value at which a critical alarm will be issued based on a sustained average ATM VCC utili… |
1.3.6.1.4.1.562.2.4.1.60.3.14.1.4 | trkAtmVccUtilAlarmStatus | 0 | 0 | This attribute provides control of the generation of ATM VCC utilization alarms. If the value is disabled, none of the alarms is… |